Sizing of atrial septal defects by intracardiac echocardiography for device closures

被引:16
作者
Chien, Jen-Chung [2 ,3 ]
Hwang, Betau [1 ,3 ,4 ]
Fu, Yun-Ching [4 ,5 ]
Lee, Pi-Chang [3 ,4 ]
Hsieh, Kai-Sheng [6 ]
Jan, Sheng-Ling [4 ,5 ]
机构
[1] Taipei City Hosp, Zhongxiao Branch, Dept Pediat, Taipei 115, Taiwan
[2] Lo Tung Pohai Hosp, Dept Pediat, Ilan, Taiwan
[3] Taipei Vet Gen Hosp, Dept Pediat, Taipei, Taiwan
[4] Natl Yang Ming Univ, Sch Med, Dept Pediat, Taipei 112, Taiwan
[5] Taichung Vet Gen Hosp, Dept Pediat, Taichung, Taiwan
[6] Kaohsiung Vet Gen Hosp, Dept Pediat, Kaohsiung, Taiwan
关键词
atrial septal defect; intracardiac echocardiography; transcatheter closure;
D O I
10.1016/S1726-4901(08)70090-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transcatheter closure of a secundum atrial septal defect (ASD) has become an effective method for surgical treatment. In this study, we evaluated the feasibility and accuracy of intracardiac echocardiography (ICE) for sizing ASDs compared with conventional methods. Methods: Between January 2004 and December 2006, 270 patients underwent transcatheter closure of secundum ASD by using septal occluders. For 142 patients, the procedure was guided by transesophageal echocardiography (TEE), and for 128 patients by ICE. We compared the maximal diameters of the ASDs obtained during angiocardiography, transthoracic echocardiography (TTE), ICE, and TEE with balloon-stretched sizes ascertained by using a sizing plate. Results: ASD diameters measured with the sizing plate were significantly correlated with those measured with ICE (r = 0.963), TEE (r = 0.912), angiography (r = 0.88), and TTE (r = 0,85). The predicted stretched diameter of the ASDs, i.e. (nonstretched diameter measured with ICE x 1.07) + 3.23 mm, agreed well with that measured by using a sizing plate (Ri = 0.974). Conclusion: ASD diameters measured with ICE correlated with sizing-plate measurements better than those determined with TEE, angiography or TTE.
引用
收藏
页码:399 / 405
页数:7
相关论文
共 28 条
[1]   Comparison of costs of intracardiac echocardiography and transesophageal echocardiography in monitoring percutaneous device closure of atrial septal defect in children and adults [J].
Alboliras, ET ;
Hijazi, ZM .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (05) :690-692
[2]  
Bartel Thomas, 2005, Eur J Echocardiogr, V6, P92, DOI 10.1016/j.euje.2004.07.007
[3]   Interatrial defect sizing by intracardiac and transesophageal echocardiography compared with fluoroscopic measurements in patients undergoing percutaneous transcatheter closure [J].
Boccalandro, F ;
Muench, A ;
Salloum, J ;
Awadalla, H ;
Carter, C ;
Barasch, E ;
Smalling, RW .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (03) :415-420
[4]   Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect [J].
Boccalandro, F ;
Baptista, E ;
Muench, A ;
Carter, C ;
Smalling, RW .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (04) :437-440
[5]  
Bruce C J, 2001, Eur J Echocardiogr, V2, P234, DOI 10.1053/euje.2001.0128
[6]   Transcatheter atrial septal defect closure: Modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer septal occluder [J].
Carlson, KM ;
Justino, H ;
O'Brien, RE ;
Dimas, VV ;
Leonard, GT ;
Pignatelli, RH ;
Mullins, CE ;
Smith, EO ;
Grifka, RG .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (03) :390-396
[7]   Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): multicentre UK experience [J].
Chan, KC ;
Godman, MJ ;
Walsh, K ;
Wilson, N ;
Redington, A ;
Gibbs, JL .
HEART, 1999, 82 (03) :300-306
[8]   Intracardiac echocardiographic guidance during transcatheter device closure of atrial septal defect and patent foramen ovale [J].
Earing, MG ;
Cabalka, AK ;
Seward, JB ;
Bruce, CJ ;
Reeder, GS ;
Hagler, DJ .
MAYO CLINIC PROCEEDINGS, 2004, 79 (01) :24-34
[9]  
El-Said H, 2001, TEX HEART I J, V28, P177
[10]   2-DIMENSIONAL ECHOCARDIOGRAPHIC AND COLOR DOPPLER MEASUREMENTS OF ATRIAL SEPTAL-DEFECT, AND COMPARISON WITH THE BALLOON-STRETCHED DIAMETER [J].
GODART, F ;
REY, C ;
FRANCART, C ;
JARRAR, M ;
VAKSMANN, G .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (14) :1095-1097