Simultaneous determination of cyclosporine and tacrolimus in human whole blood by ultra-high performance liquid chromatography tandem mass spectrometry and comparison with a chemiluminescence microparticle immunoassay

被引:22
作者
Mei, Shenghui [1 ,2 ]
Wang, Jiaqing [1 ]
Chen, Di [3 ]
Zhu, Leting [1 ]
Zhao, Ming [3 ]
Tian, Xiaoxin [3 ]
Hu, Xin [3 ]
Zhao, Zhigang [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Tiantan Hosp, Dept Pharm, 6 Tiantan Xili, Beijing 100050, Peoples R China
[2] Capital Med Univ, Coll Pharmaceut Sci, Dept Clin Pharmacol, Beijing 100045, Peoples R China
[3] Beijing Hosp, Natl Ctr Gerontol, Dept Pharm, 1 Dahua Rd, Beijing 100005, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2018年 / 1087卷
关键词
UHPLC-MS/MS; Cyclosporine; Tacrolimus; Immunosuppressive drug monitoring; Chemiluminescence microparticle immunoassay; Method comparison; MYCOPHENOLIC-ACID; MS/MS METHOD; SIROLIMUS; QUANTIFICATION; ASSAY; EVEROLIMUS; METABOLITES; AGREEMENT; SAMPLES;
D O I
10.1016/j.jchromb.2018.04.028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Overestimation of immunoassays for cyclosporine (CsA) and tacrolimus (TAC) analysis in human whole blood is a problem. The liquid chromatography tandem mass spectrometry is recommended as a golden method for CsA and TAC analysis. The aim of the study is to develop and validate an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of CsA and TAC in human whole blood and evaluate its agreement with a chemiluminescence microparticle immunoassay (CMIA). The UHPLC-MS/MS method for simultaneous determination of CsA and TAC in human whole blood was developed and validated according to the guidelines. A total of 177 CsA and 220 TAC samples were determined by UHPLC-MS/MS and CMIA, and the agreement of the two methods was evaluated by Bland-Altman plot. The calibration range of UHPLC-MS/MS method was 5 to 2000 ng/mL for CsA and 0.2 to 80 ng/mL for TAC. The inaccuracy and imprecision were - 13.33% to 11.80% and < 11.74% for CsA and - 8.94% to 6.53% and < 10.84% for TAC, respectively. Evaluated by Bland-Altman plot, the mean overestimation of CMIA compared to UHPLC-MS/MS was 53.7% for CsA and 48.1% for TAC.
引用
收藏
页码:36 / 42
页数:7
相关论文
共 45 条
[1]  
[Anonymous], 2013, Guidance for industry # 213
[2]   Quantification of cyclosporine and tacrolimus in whole blood. Comparison of liquid chromatography-electrospray mass spectrometry with the enzyme multiplied immunoassay technique [J].
Ansermot, Nicolas ;
Fathi, Marc ;
Veuthey, Jean-Luc ;
Desmeules, Jules ;
Rudaz, Serge ;
Hochstrasser, Denis .
CLINICAL BIOCHEMISTRY, 2008, 41 (10-11) :910-913
[3]  
Armstrong VW, 1998, CLIN CHEM, V44, P2516
[4]   Evaluation of a Novel Commercial Assay for the Determination of Cyclosporine A, Tacrolimus, Sirolimus, and Everolimus by Liquid Chromatography-Tandem Mass Spectrometric Assay [J].
Becker, Susen ;
Thiery, Joachim ;
Ceglarek, Uta .
THERAPEUTIC DRUG MONITORING, 2013, 35 (01) :129-132
[5]   Simultaneous Determination of Protein-Unbound Cyclosporine A and Mycophenolic Acid in Kidney Transplant Patients Using Liquid Chromatography-Tandem Mass Spectrometry [J].
Bittersohl, Heike ;
Herbinger, Juliane ;
Wen, Ming ;
Renders, Lutz ;
Steimer, Werner ;
Luppa, Peter B. .
THERAPEUTIC DRUG MONITORING, 2017, 39 (03) :211-219
[6]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[7]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[8]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]   Simultaneous LC-MS-MS determination of cyclosporine A, tacrolimus, and sirolimus in whole blood as well as mycophenolic acid in plasma using common pretreatment procedure [J].
Bogusz, Maciej J. ;
Al Enazi, Eid ;
Hassan, Huda ;
Abdel-Jawaad, Jamil ;
Al Ruwaily, Jamal ;
Al Tufail, Mohammed .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2) :471-480
[10]   Liquid chromatography-tandem mass spectrometry method for simultaneous determination of cyclosporine A and its three metabolites AM1, AM9 and AM4N in whole blood and isolated lymphocytes in renal transplant patients [J].
Brozmanova, Hana ;
Perinova, Ilona ;
Halvova, Petra ;
Grundmann, Milan .
JOURNAL OF SEPARATION SCIENCE, 2010, 33 (15) :2287-2293