Relationship of Plasma Metal Ions and Clinical and Imaging Findings in Patients with ASR XL Metal-on-Metal Total Hip Replacements

被引:49
作者
Chang, Eric Y. [1 ]
McAnally, James L. [1 ]
Van Horne, James R. [1 ]
Van Horne, James G. [1 ]
Wolfson, Tanya [1 ]
Gamst, Anthony [1 ]
Chung, Christine B. [1 ]
机构
[1] VA San Diego Healthcare Syst, San Diego, CA 92161 USA
关键词
DIAMETER TOTAL HIP; EARLY FAILURE; INFLAMMATORY PSEUDOTUMOR; GROIN PAIN; FOLLOW-UP; ARTHROPLASTY; CHROMIUM; COBALT; COMPONENTS; BLOOD;
D O I
10.2106/JBJS.L.01481
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Plasma metal ion levels are commonly used in the postoperative follow-up evaluation of patients who have had a metal-on-metal hi p,arthroplasty. However, the relationship between these levels and clinical and imaging findings is not well known. Methods: We evaluated 156 consecutive patients who received a unilateral ASR XL total hip replacement. Patients presented, regardless of symptoms, in response to a voluntary recall of the hip replacement by the manufacturer and were assessed with regard to the presence and type of symptoms and plasma cobalt-chromium levels. In addition, radiographic and magnetic resonance imaging studies were performed and analyzed. Results: Eighty patients were asymptomatic, and seventy-six patients were symptomatic. The median cobalt level was 1.8 ppb, and the median chromium level was 1.0 ppb (at or below measurement threshold). Pseudotumors that could be detected on magnetic resonance imaging were seen in 69% (107) of 156 patients, and radiographic osteolysis was evident in 7% (eleven patients). At a threshold of 5 ppb, no association was detected between abnormal metal ion levels and patient symptoms, prosthetic femoral head size, or acetabular cup inclination. An abnormal cobalt level was significantly associated with the presence of periprosthetic lucency on radiographs and pseudotumor on magnetic resonance imaging (p < 0.05). An abnormal chromium level showed a similar pattern, but the relationships did not reach significance. Both abnormal plasma cobalt and chromium levels were associated with larger sizes of pseudotumor when present (p < 0.05). Conclusions: In our sample, with a threshold of 5 ppb, abnormal plasma metal ions were associated with larger sizes of pseudotumors when present, but were not predictive of patient symptoms. Abnormal plasma cobalt levels have a significant association with periprosthetic lucency and presence of pseudotumor. Plasma chromium shows a similar pattern of association with lucency and presence of pseudotumor, although the relationships were not significant. Metal ion analysis should be used in conjunction with clinical and imaging evaluation and not as a sole indirect screening test when evaluating patients following metal-on-metal hip arthroplasty.
引用
收藏
页码:2015 / 2020
页数:6
相关论文
共 49 条
[1]   Metal ion levels in the blood of patients after hip resurfacing: A comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses [J].
Antoniou, John ;
Zukor, David J. ;
Mwale, Fackson ;
Minarik, William ;
Petit, Alain ;
Huk, Olga L. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A :142-148
[2]   Autopsy analysis thirty years after metal-on-metal total hip replacement - A case report [J].
Campbell, P ;
Urban, RM ;
Catelas, I ;
Skipor, AK ;
Schmalzried, TP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2218-2222
[3]   Histological Features of Pseudotumor-like Tissues From Metal-on-Metal Hips [J].
Campbell, Pat ;
Ebramzadeh, Edward ;
Nelson, Scott ;
Takamura, Karren ;
De Smet, Koen ;
Amstutz, Harlan C. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (09) :2321-2327
[4]   Metal-on-Metal Total Hip Arthroplasty: Do Symptoms Correlate with MR Imaging Findings? [J].
Chang, Eric Y. ;
McAnally, James L. ;
Van Horne, James R. ;
Statum, Sheronda ;
Wolfson, Tanya ;
Gamst, Anthony ;
Chung, Christine B. .
RADIOLOGY, 2012, 265 (03) :848-857
[5]   The validity of serum levels as a surrogate measure of systemic exposure to metal ions in hip replacement [J].
Daniel, J. ;
Ziaee, H. ;
Pynsent, P. B. ;
McMinn, D. J. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (06) :736-741
[6]   Pseudotumors Associated with Total Hip Arthroplasty [J].
Daniel, Joseph ;
Holland, James ;
Quigley, Laura ;
Sprague, Sheila ;
Bhandari, Mohit .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (01) :86-93
[7]   Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip Resurfacing [J].
de Smet, K. ;
de Haan, R. ;
Calistri, A. ;
Campbell, P. A. ;
Ebramzadeh, E. ;
Pattyn, C. ;
Gill, H. S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A :202-208
[8]   Revisions of Metal-on-Metal Hip Resurfacing: Lessons Learned and Improved Outcome [J].
De Smet, Koen A. ;
Van der Straeten, Catherine ;
Van Orsouw, Maarten ;
Doubi, Rachid ;
Backers, Katrien ;
Grammatopoulos, George .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2011, 42 (02) :259-+
[9]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[10]   Metal ion levels after metal-on-metal proximal femoral replacements - A 30-year follow-up [J].
Dunstan, E ;
Sanghrajka, AP ;
Tilley, S ;
Unwin, P ;
Blunn, G ;
Cannon, SR ;
Briggs, TWR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (05) :628-631