Lacunarity analysis of spatial pattern in CT images of vertebral trabecular bone for assessing osteoporosis

被引:50
作者
Dougherty, G
Henebry, GM
机构
[1] Kuwait Univ, Fac Allied Hlth Sci, Dept Radiol Sci, Kuwait, Kuwait
[2] Univ Nebraska, Ctr Adv Land Management Informat Technol, Lincoln, NE 68588 USA
关键词
lacunarity; texture; bone quality; trabecular bone; computed tomography;
D O I
10.1016/S1350-4533(01)00106-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The structural integrity of vertebral trabecular bone is determined by the continuity of its trabecular network and the size of the holes comprising its marrow space, both of which determine the apparent size of the marrow spaces in a transaxial CT image. A model-independent assessment of the trabeculation pattern was determined from the lacunarity of thresholded CT images. Using test images of lumbar vertebrae from human cadavers, acquired at different slice thicknesses, we determined that both median thresholding and local adaptive thresholding (using a 7x7 window) successfully segmented the grey-scale images. Lacunarity analysis indicated a multifractal nature to the images, and a range of marrow space sizes with significant structure around 14-18 mm(2). Preliminary studies of in vivo images from a clinical CT scanner indicate that lacunarity analysis can follow the pattern of bone loss in osteoporosis by monitoring the homogeneity of the marrow spaces, which is related to the connectivity of the trabecular bone network and the marrow space sizes. Although the patient sample was small, derived parameters such as the maximum deviation of the lacunarity from a neutral (fractal) model, and the maximum derivative of this deviation, seem to be sufficiently sensitive to distinguish a range of bone conditions. Our results suggest that these parameters, used with bone mineral density values, may have diagnostic value in characterizing osteoporosis and predicting fracture risk. (C) 2002 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:129 / 138
页数:10
相关论文
共 43 条
[1]   CHARACTERIZING THE LACUNARITY OF RANDOM AND DETERMINISTIC FRACTAL SETS [J].
ALLAIN, C ;
CLOITRE, M .
PHYSICAL REVIEW A, 1991, 44 (06) :3552-3558
[2]  
ANDRESEN R, 1994, INT J BONE MINER S2, V25, P14
[3]  
[Anonymous], 1983, New York
[4]   MEASUREMENT OF ANISOTROPIC VERTEBRAL TRABECULAR BONE LOSS DURING AGING BY QUANTITATIVE IMAGE-ANALYSIS [J].
BERGOT, C ;
LAVALJEANTET, AM ;
PRETEUX, F ;
MEUNIER, A .
CALCIFIED TISSUE INTERNATIONAL, 1988, 43 (03) :143-149
[5]   FRACTAL SIGNATURE ANALYSIS OF MACRORADIOGRAPHS MEASURES TRABECULAR ORGANIZATION IN LUMBAR VERTEBRAE OF POSTMENOPAUSAL WOMEN [J].
BUCKLANDWRIGHT, JC ;
LYNCH, JA ;
RYMER, J ;
FOGELMAN, I .
CALCIFIED TISSUE INTERNATIONAL, 1994, 54 (02) :106-112
[6]   Parallel plate model for trabecular bone exhibits volume fraction-dependent bias [J].
Day, JS ;
Ding, M ;
Odgaard, A ;
Sumner, DR ;
Hvid, I ;
Weinans, H .
BONE, 2000, 27 (05) :715-720
[7]   A comparison of the texture of computed tomography and projection radiography images of vertebral trabecular bone using fractal signature and lacunarity [J].
Dougherty, G .
MEDICAL ENGINEERING & PHYSICS, 2001, 23 (05) :313-321
[8]   Bone density measured by dual-energy X-ray absorptiometry in healthy Kuwaiti women [J].
Dougherty, G ;
Al-Marzouk, N .
CALCIFIED TISSUE INTERNATIONAL, 2001, 68 (04) :225-229
[9]   Fractal signature and lacunarity in the measurement of the texture of trabecular bone in clinical CT images [J].
Dougherty, G ;
Henebry, GM .
MEDICAL ENGINEERING & PHYSICS, 2001, 23 (06) :369-380
[10]   Measurement of thickness and density of thin structures by computed tomography: A simulation study [J].
Dougherty, G ;
Newman, D .
MEDICAL PHYSICS, 1999, 26 (07) :1341-1348