Molecularly imprinted stir bar sorptive extraction coupled with atomic absorption spectrometry for trace analysis of copper in drinking water samples

被引:29
作者
Hashemi, Hossein [1 ]
Khajeh, Mostafa [2 ]
Kaykhaii, Massoud [1 ]
机构
[1] Univ Sistan & Baluchestan, Dept Chem, Fac Sci, Zahedan 98135674, Iran
[2] Univ Zabol, Dept Chem, Zabol, Iran
关键词
SOLID-PHASE EXTRACTION; MICROEXTRACTION; PRECONCENTRATION; POLYMER; CU(II); IONS; IRON; GEL;
D O I
10.1039/c3ay40355f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a novel molecularly imprinted polymer (MIP) coated stir bar was fabricated and used for the extraction of trace amounts of Cu from drinking water. Cu-morin complex was used as template molecule which was chemically bonded to a glass stir bar and was employed for stir bar sorptive extraction of trace amounts of copper ions. The effects of different parameters such as pH, adsorption and desorption time, stirring rate, temperature and amount of ligand (morin) were evaluated on the extraction efficiency and the optimum conditions were established: the extraction and desorption times were fixed respectively at 20 and 30 min, mole ratio of ligand to the analyte was selected as 2, stirring speed was 700 rpm, pH was adjusted to 5 and the extraction process was performed at a temperature of 45 degrees C. Under these conditions, a pre-concentration factor of 25 was achieved and the total capacity of the stir bar for copper uptake was found to be 1200 mu g. A non-imprinted polymer coating was used for comparison. The MIP stir bar showed sufficient mechanical and chemical stability and was able to perform more than 50 extractions without any damage to the polymer phase. The reproducibility between stir bars (n = 5) was 8.9%. The detection limit of the proposed method was found to be 0.38 mu g L-1 with a relative standard deviation within 0.56-5.3% and a dynamic range between 1 and 1000 mu g L-1. The method was successfully applied to the pre-concentration and determination of copper in a few different water samples.
引用
收藏
页码:2778 / 2783
页数:6
相关论文
共 28 条
  • [1] Optimization of solid-phase extraction based on a new sol-gel material using a response surface methodology for the determination of copper in water samples by flame atomic absorption spectrometry
    Abdolmohammad-Zadeh, Hossein
    Naseri, Abdolhossein
    Galeh-Assadi, Mohammad
    Shabkhizan, Somayeh
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (03) : 279 - 297
  • [2] Direct sample introduction of wines in graphite furnace atomic absorption spectrometry for the simultaneous determination of arsenic, cadmium, copper and lead content
    Ajtony, Zsolt
    Szoboszlai, Norbert
    Susko, Emoke Klaudia
    Mezei, Pal
    Gyoergy, Krisztina
    Bencs, Laszlo
    [J]. TALANTA, 2008, 76 (03) : 627 - 634
  • [3] Direct determination of trace elements in boron nitride powders by slurry sampling total reflection X-ray fluorescence spectrometry
    Amberger, Martin A.
    Hoeltig, Michael
    Broekaert, Jose A. C.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (02) : 152 - 157
  • [4] Extraction of Cu(II) from aqueous solutions by vegetable oil-based organic solvents
    Chang, Siu Hua
    Teng, Tjoon Tow
    Ismail, Norli
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2010, 181 (1-3) : 868 - 872
  • [5] Chemically modified silica gel with p-dimethylaminobenzaldehyde for selective solid-phase extraction and preconcentration of Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) by ICP-OES
    Cui, Yuemei
    Chang, Xijun
    Zhu, Xiangbing
    Luo, Haixia
    Hu, Zheng
    Zou, Xiaojun
    He, Qun
    [J]. MICROCHEMICAL JOURNAL, 2007, 87 (01) : 20 - 26
  • [6] Cloud point extraction and flame atomic absorption spectrometry determination of trace amounts of copper(II) ions in water samples
    Fathi, S. A. M.
    Yaftian, M. R.
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2009, 334 (02) : 167 - 170
  • [7] Hosseini M, 2012, INDIAN J CHEM TECHN, V19, P337
  • [8] Development of selective and chemically stable coating for stir bar sorptive extraction by molecularly imprinted technique
    Hu, Yuling
    Li, Jiawei
    Hu, Yufei
    Li, Gongke
    [J]. TALANTA, 2010, 82 (02) : 464 - 470
  • [9] SOLID-PHASE MICROEXTRACTION FOR THE DETERMINATION OF INORGANIC IONS: APPLICATIONS AND POSSIBILITIES
    Kaykhaii, Massoud
    Dicinoski, Greg W.
    Haddad, Paul R.
    [J]. ANALYTICAL LETTERS, 2010, 43 (10-11) : 1546 - 1555
  • [10] Khajeh M, 2009, ENVIRON CHEM LETT, V9, P177