Translating Molecular Recognition into a Pressure Signal to enable Rapid, Sensitive, and Portable Biomedical Analysis

被引:163
作者
Zhu, Zhi [1 ]
Guan, Zhichao [1 ]
Liu, Dan [1 ]
Jia, Shasha [1 ]
Li, Jiuxing [1 ]
Lei, Zhichao [1 ]
Lin, Shuichao [1 ]
Ji, Tianhai [1 ]
Tian, Zhongqun [1 ]
Yang, Chaoyong James [1 ]
机构
[1] Xiamen Univ, State Key Lab Phys Chem Solid Surfaces,Coll Chem, MOE Key Lab Spectrochem Anal & Instrumentat,Dept, Collaborat Innovat Ctr Chem Energy Mat,Key Lab Ch, Xiamen 361005, Peoples R China
基金
美国国家科学基金会;
关键词
gas generation; hydrogen peroxide; immunoassay; point-of-care testing; pressure measurement; OF-CARE DIAGNOSTICS; BAR-CHART CHIP; POINT; GLUCOSE; PAPER; HYDROGEL; READOUT; DEVICES; TARGETS; SENSOR;
D O I
10.1002/anie.201503963
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Herein, we demonstrate that a very familiar, yet underutilized, physical parametergas pressurecan serve as signal readout for highly sensitive bioanalysis. Integration of a catalyzed gas-generation reaction with a molecular recognition component leads to significant pressure changes, which can be measured with high sensitivity using a low-cost and portable pressure meter. This new signaling strategy opens up a new way for simple, portable, yet highly sensitive biomedical analysis in a variety of settings.
引用
收藏
页码:10448 / +
页数:6
相关论文
共 30 条
[1]   A novel magnetic bead bioassay platform using a microchip-based sensor for infectious disease diagnosis [J].
Aytur, Turgut ;
Foley, Jonathan ;
Anwar, Mekhail ;
Boser, Bernhard ;
Harris, Eva ;
Beatty, P. Robert .
JOURNAL OF IMMUNOLOGICAL METHODS, 2006, 314 (1-2) :21-29
[2]   Simple, distance-based measurement for paper analytical devices [J].
Cate, David M. ;
Dungchai, Wijitar ;
Cunningham, Josephine C. ;
Volckens, John ;
Henry, Charles S. .
LAB ON A CHIP, 2013, 13 (12) :2397-2404
[3]   Human influenza A H5N1 virus related to a highly pathogenic avian influenza virus [J].
Claas, ECJ ;
Osterhaus, ADME ;
van Beek, R ;
De Jong, JC ;
Rimmelzwaan, GF ;
Senne, DA ;
Krauss, S ;
Shortridge, KF ;
Webster, RG .
LANCET, 1998, 351 (9101) :472-477
[4]   Diagnostic point-of-care tests in resource-limited settings [J].
Drain, Paul K. ;
Hyle, Emily P. ;
Noubary, Farzad ;
Freedberg, Kenneth A. ;
Wilson, Douglas ;
Bishai, William R. ;
Rodriguez, William ;
Bassett, Ingrid V. .
LANCET INFECTIOUS DISEASES, 2014, 14 (03) :239-249
[5]   REACTION BETWEEN CATALASE AND HYDROGEN PEROXIDE [J].
GEORGE, P .
NATURE, 1947, 160 (4054) :41-43
[6]   Drivers of biodiagnostic development [J].
Giljohann, David A. ;
Mirkin, Chad A. .
NATURE, 2009, 462 (7272) :461-464
[7]   Kinetic analysis of superoxide anion radical-scavenging and hydroxyl radical-scavenging activities of platinum nanoparticles [J].
Hamasaki, Takeki ;
Kashiwagi, Taichi ;
Imada, Toshifumi ;
Nakamichi, Noboru ;
Aramaki, Shinsuke ;
Toh, Kazuko ;
Morisawa, Shinkatsu ;
Shimakoshi, Hisashi ;
Hisaeda, Yoshio ;
Shirahata, Sanetaka .
LANGMUIR, 2008, 24 (14) :7354-7364
[8]  
Lewis G.G., 2012, Angewandte Chemie, V124, P12879, DOI DOI 10.1002/ange.201207239
[9]   Quantifying Analytes in Paper-Based Microfluidic Devices Without Using External Electronic Readers [J].
Lewis, Gregory G. ;
DiTucci, Matthew J. ;
Phillips, Scott T. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (51) :12707-12710
[10]   Magnetic Relaxation Detector for Microbead Labels [J].
Liu, Paul Peng ;
Skucha, Karl ;
Duan, Yida ;
Megens, Mischa ;
Kim, Jungkyu ;
Izyumin, Igor I. ;
Gambini, Simone ;
Boser, Bernhard .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2012, 47 (04) :1056-1064