ANALYSIS OF THE REASONS FOR THE LEAKAGE OF A BOILER WATER-WALL TUBE IN A POWER PLANT

被引:1
作者
Guo, Ruidong [1 ]
Xue, Song [1 ,2 ]
Yang, Tao [1 ]
Liu, Xuedong [1 ]
机构
[1] Southwest Univ Sci & Technol, Coll Mfg Sci & Engn, Mianyang 621010, Sichuan, Peoples R China
[2] Minist Educ, Key Lab Testing Technol Mfg Proc, Mianyang 621010, Sichuan, Peoples R China
来源
MATERIALI IN TEHNOLOGIJE | 2020年 / 54卷 / 02期
关键词
boiler water-wall tube; overheating; deposits; leakage; FAILURE ANALYSIS; CORROSION; SUPERHEATER; STEEL;
D O I
10.17222/mit.2019.205
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the present research, the leakage causes of a boiler water-wall tube, with an outside diameter of 60 mm and a thickness of 6.75 mm, that transmits the water medium have been studied. Leakage occurred on the fire-facing side of the tube and close to the boiler. Various techniques including visual inspection, chemical composition analysis. Vickers hardness test, tube wall thickness measurements, mechanical performance testing, optical microscopy and energy-dispersive spectroscopy were carried out to verify the probable cause of failure. Deposits formed on the inner wall of the tube, which caused local heat-transfer performance of the tube to decrease, formed an overheating characteristic in the microstructure. and softened the tube wall and made the tube wall thinner near the leakage points. The softening of the tube wall reduces the measured hardness at the edge of the leakage point. In addition, due to the localized wall thinning and softening, the tube cannot withstand the stress flowing liquids and gases. with the result that the tube was bulging and deforming. Local overheating caused the degeneration of the initial ferrite-pearlite microstructure. In the microstructure near the leakage point of the water-wall tube, carbides were spheroidized and coalesced. According to the investigation, it was concluded that the local heat-transfer performance of the water-wall tube decreased and the tube performance deteriorated due to the deposits formed on the inner surface. The combination of localized overheating and tube wall thinning led to the tube's premature bulging and failure while running.
引用
收藏
页码:221 / 226
页数:6
相关论文
共 25 条
[1]  
Abou-Elazm A. Saad, 2009, ENG FAIL ANAL, V16, P433, DOI [10.1016/j.eng- failanal.2008.06.024, DOI 10.1016/J.ENG-FAILANAL.2008.06.024]
[2]   Failure Analysis of Stainless Steel Heat Exchanger Tubes in a Petrochemical Plant [J].
Adnyana, D. N. .
JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2018, 18 (02) :413-422
[3]   Hydrogen damage in a rear riser water wall tube of a power plant [J].
Ahmad, J. ;
Purbolaksono, J. .
ENGINEERING FAILURE ANALYSIS, 2010, 17 (05) :1239-1245
[4]   Failure investigation on rear water wall tube of boiler [J].
Ahmad, J. ;
Purbolaksono, J. ;
Beng, L. C. ;
Rashid, A. Z. ;
Khinani, A. ;
Ali, A. A. .
ENGINEERING FAILURE ANALYSIS, 2009, 16 (07) :2325-2332
[5]  
[Anonymous], DLT8842004 STAND EL
[6]  
[Anonymous], 1998, ASM HDB, V11, P628
[7]   The erosion-corrosion performance of SA213-T22 steel in low velocity conditions [J].
Chacón-Nava, JG ;
Stott, FH ;
Martínez-Villafañe, A ;
Almeraya-Calderón, FM ;
González-Rodríguez, JG .
JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2001, 10 (06) :699-704
[8]   Metallurgical investigation of failed boiler water-wall tubes received from a thermal power station [J].
Dhua, S. K. .
ENGINEERING FAILURE ANALYSIS, 2010, 17 (7-8) :1572-1579
[9]   Failure analysis of the wall tubes of a water-tube boiler [J].
Duarte, Camilo A. ;
Espejo, Edgar ;
Carlos Martinez, Juan .
ENGINEERING FAILURE ANALYSIS, 2017, 79 :704-713
[10]   Failure analysis of a superheater tube ruptured in a power plant boiler: Main causes and preventive strategies [J].
Haghighat-Shishavan, Babak ;
Firouzi-Nerbin, Hossein ;
Nazarian-Samani, Masoud ;
Ashtari, Pooria ;
Nasirpouri, Farzad .
ENGINEERING FAILURE ANALYSIS, 2019, 98 :131-140