Induced voltage and current in parallel transmission lines: Causes and concerns

被引:15
|
作者
Horton, Randy [1 ]
Wallace, Keith [1 ]
机构
[1] Alabama Power Co, Birmingham, AL 35203 USA
关键词
electromagnetic induction; grounding; safety;
D O I
10.1109/TPWRD.2008.2002658
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Induced voltage and current in a deenergized transmission line caused by other lines nearby can be caused by electric-field and magnetic-field induction. These voltages and currents present a serious work hazard for line-crew personnel. Proper understanding of the phenomenon involved and identification of the associated hazards are necessary to safely perform deenergized line work. The purpose of this paper is to clarify some of the misconceptions that have been prevalent in the industry for many years as well as to expand on the test data available in literature. This paper discusses, in simple terms, the relevant parameters that affect the magnitude of the induced voltage and current as well as the work hazards they create.
引用
收藏
页码:2339 / 2346
页数:8
相关论文
共 50 条
  • [1] Fault Location for Parallel Transmission Lines with Limited Voltage and Current Measurements
    Xiu, Wanjing
    Liao, Yuan
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2013, 14 (03): : 265 - 274
  • [2] Induced voltage in parallel transmission lines caused by electric field induction
    Horton, Randy
    Halpin, Mark
    Wallace, Keith
    ESMO 2006-2006 IEEE 11th International Conference on Transmission & Distribution Construction, Operation and Live-Line Maintenance, 2006, : 150 - 156
  • [3] Calculation of Induced Voltage and Current on a Crossing Transmission Line under UHV AC Transmission Lines
    Li Yuze
    Kong Xiaofeng
    Zhang Bo
    2019 IEEE ASIA POWER AND ENERGY ENGINEERING CONFERENCE (APEEC 2019), 2019, : 132 - 136
  • [4] Transient voltage and current distributions on transmission lines
    Mamis, MS
    Nacaroglu, A
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2002, 149 (06) : 705 - 712
  • [5] Calculation of induced current in the objects placed in the vicinity of the high voltage transmission lines
    Abdelber, Bendaoud
    Benhamida, F.
    Tilmatine, A.
    Medles, K.
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (12): : 310 - 314
  • [6] Harmonic resonance on parallel high voltage transmission lines
    Harries, JR
    Randall, JL
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (01) : 477 - 482
  • [7] Calculation of an induced voltage on telecommunication lines in parallel distribution lines
    Trans. Korean Inst. Electr. Eng., 2008, 10 (1688-1695):
  • [8] Environmental concerns for high-voltage transmission lines in UNIPEDE countries
    Kalkani, EC
    Boussiakon, LG
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1996, 122 (11): : 1042 - 1045
  • [9] Evaluation of induced voltage and current on low-voltage distribution lines under EHV/UHV AC and DC transmission lines
    He, Yuwei
    Liu, Yakun
    Yan, Nannan
    Li, Shilong
    Wei, Bengang
    Wang, Liming
    Fu, Zhengcai
    Dianwang Jishu/Power System Technology, 2015, 39 (09): : 2640 - 2646
  • [10] CAPACITIVE INDUCED VOLTAGES IN PARALLEL TRANSMISSION LINES
    Costea, Marian
    Baran, Ileana
    Leonida, Tudor
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2014, 76 (04): : 199 - 206