Novel Implant Design for Initial Stability of Dental Implants Inserted in Fresh Extraction Sockets: A Preliminary Study

被引:4
作者
Levin, Liran [1 ,2 ]
Frankenthal, Shai [1 ]
Zigdon, Hadar [1 ,2 ]
Suzuki, Marcelo [3 ]
Coelho, Paulo G. [4 ]
机构
[1] Rambam Hlth Care Campus, Dept Periodontol, Sch Grad Dent, Haifa, Israel
[2] Technion Israel Inst Technol, Fac Med, Haifa, Israel
[3] Tufts Univ, Sch Dent Med, Dept Prosthodont & Operat Dent, Boston, MA 02111 USA
[4] NYU, Dept Biomat & Biomimet, New York, NY USA
关键词
implant failure; immediate implantation; implant success; bone loss; torque; SINGLE-TOOTH IMPLANTS; IMMEDIATE; MOLAR; REPLACEMENT; PLACEMENT; SURVIVAL; OUTCOMES; SUCCESS;
D O I
10.1097/ID.0b013e31825cd43b
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate a novel implant design for immediate implantation. This implant presents a specially designed expanded diameter midcrestal "wing" thread, which is aimed to provide added bone contact for greater insertion torque and primary stability. Methods: Mandibular premolars were extracted in 2 mongrel dogs, and immediate dental implants were inserted into the fresh extraction sockets. Implants were evaluated for stability using a resonance frequency analysis device immediately after insertion and after 4 and 8 weeks. Removal torque of 1 randomly selected implant in each hemimandible was measured as well. At 8 weeks, the remaining 6 implants were processed histologically. Results: Mean implant stability quotient at implant placement was 64.38 (5.03) and 74.5 (3.08) at 8 weeks. Average removal torque immediately after implant placement was 49.65 (20.3) N.cm and 98.33 (12.34) N.cm at 8 weeks. The mean bone-to-implant contact value at 8 weeks was 38.89% (7.65%). Conclusions: The examined implant with the expanded diameter midcrestal "wing" thread showed good results of resonance frequency analysis and removal torque during the initial healing phase, and as such, it might be used for immediate implantation and loading. (Implant Dent 2012;21:302-305)
引用
收藏
页码:302 / 305
页数:4
相关论文
共 26 条
[1]  
Aparicio Carlos, 2003, Clin Implant Dent Relat Res, V5, P57, DOI 10.1111/j.1708-8208.2003.tb00183.x
[2]  
Atieh MA, 2010, INT J ORAL MAX IMPL, V25, P401
[3]   Immediate implant loading: Current status from available literature [J].
Avila, Gustavo ;
Galindo, Pablo ;
Rios, Hector ;
Wang, Hom-Lay .
IMPLANT DENTISTRY, 2007, 16 (03) :235-242
[4]  
Chen ST, 2009, INT J ORAL MAX IMPL, V24, P186
[5]   Immediate Loading in the Maxillary Arch: Evidence-Based Guidelines to Improve Success Rates: A Review [J].
Chung, Sean ;
McCullagh, Anthony ;
Irinakis, Tassos .
JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (05) :610-621
[6]  
Degidi Marco, 2005, J Oral Implantol, V31, P247, DOI 10.1563/1548-1336(2005)31[247:HAOAIL]2.0.CO
[7]  
2
[8]   Immediate Loading of Freestanding Implants Using Cortical Satellite Implants: 3-Year Results of an Ongoing Prospective Study [J].
Engelke, Wilfried ;
Decco, Oscar A. ;
Cura, Andrea C. ;
Ruscio, Mara L. .
IMPLANT DENTISTRY, 2011, 20 (05) :341-344
[9]   RETRACTED: Interventions for replacing missing teeth: different types of dental implants (Retracted Article) [J].
Esposito, M. ;
Murray-Curtis, L. ;
Grusovin, M. G. ;
Coulthard, P. ;
Worthington, H., V .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2007, (04)
[10]  
Esposito M, 2010, EUR J ORAL IMPLANTOL, V3, P3