Freestanding Cu nanowire arrays on Ti/Cr/Si substrate as tough nonenzymatic glucose sensors

被引:16
作者
Zhang, Li [1 ]
Zhang, Junyi [1 ]
Yang, Chunli [1 ]
Zhao, Guangyu [1 ]
Mu, Jianshuai [1 ]
Wang, Yan [1 ]
机构
[1] Harbin Inst Technol, Acad Fundamental & Interdisciplinary Sci, Harbin 150080, Heilongjiang, Peoples R China
来源
RSC ADVANCES | 2015年 / 5卷 / 101期
基金
美国国家科学基金会;
关键词
WALLED CARBON NANOTUBES; ELECTROCHEMICAL DETECTION; IMPROVED SENSITIVITY; COPPER NANOPARTICLES; FACILE FABRICATION; ALKALINE MEDIA; POROUS GOLD; ELECTRODE; PLATINUM; HYBRID;
D O I
10.1039/c5ra10058e
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Exploring a tough, reusable and reproducible nonenzymatic sensor for glucose detection is required. Cu nanowire array electrodes on a Ti/Cr/Si substrate are prepared from an anodic aluminum oxide template film covered Ti/Cr/Si substrate by an electrodeposition method. The scanning electron microscope results indicate that Cu nanowires with a diameter of 50 nm and a length of hundreds of nm freestanding on the Ti/Cr/Si substrate are obtained. Electrochemical measurements indicate the freestanding nanowire array electrodes showing sensitivity of 1067 mu A mM(-1) cm(-2) and detection limit of 1.87 mu M when using the arrays as glucose sensors. The most attractive characteristics of the electrodes are the outstanding reusability and reproducibility, realizing a 1.77% relative standard deviation (RSD) of one electrode in five time tests and a 3.33% RSD of five electrodes for one sample. The application of the electrodes on determining the glucose concentration in human serum samples indicates the array electrode is a promising candidate as a practical sensor.
引用
收藏
页码:82998 / 83003
页数:6
相关论文
共 39 条
  • [1] Single step modification of copper electrode for the highly sensitive and selective non-enzymatic determination of glucose
    Babu, T. G. Satheesh
    Ramachandran, T.
    Nair, Bipin
    [J]. MICROCHIMICA ACTA, 2010, 169 (1-2) : 49 - 55
  • [2] Nonenzymatic glucose detection with good selectivity against ascorbic acid on a highly porous gold electrode subjected to amalgamation treatment
    Cho, Sangeun
    Kang, Chan
    [J]. ELECTROANALYSIS, 2007, 19 (22) : 2315 - 2320
  • [3] Direct electrodeposition of cable-like CuO@Cu nanowires array for non-enzymatic sensing
    Dong, Junping
    Ren, Linxiao
    Zhang, Yuan
    Cui, Xiaoli
    Hu, Pengfei
    Xu, Jiaqiang
    [J]. TALANTA, 2015, 132 : 719 - 726
  • [4] Electrochemical determination of hydrogen peroxide using copper/porous silicon based non-enzymatic sensor
    Ensafi, Ali A.
    Abarghoui, M. Mokhtari
    Rezaei, B.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 398 - 405
  • [5] One-pot hydrothermal synthesis of CuO with tunable morphologies on Ni foam as a hybrid electrode for sensing glucose
    Fan, Zengjie
    Liu, Bin
    Li, Zhangpeng
    Ma, Limin
    Wang, Jinqing
    Yang, Shengrong
    [J]. RSC ADVANCES, 2014, 4 (44) : 23319 - 23326
  • [6] Oxidation and photo-induced oxidation of glucose at a polyaniline film modified by copper particles
    Farrell, ST
    Breslin, CB
    [J]. ELECTROCHIMICA ACTA, 2004, 49 (25) : 4497 - 4503
  • [7] High performance non-enzymatic glucose biosensor based on copper nanowires-carbon nanotubes hybrid for intracellular glucose study
    Huang, Jingwei
    Dong, Zhengping
    Li, Yingdong
    Li, Jing
    Wang, Jia
    Yang, Haidong
    Li, Shuwen
    Guo, Shujing
    Jin, Jun
    Li, Rong
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 182 : 618 - 624
  • [8] Reticular-vein-like Cu@Cu2O/reduced graphene oxide nanocomposites for a non-enzymatic glucose sensor
    Huo, Huanhuan
    Guo, Chunyan
    Li, Guilin
    Han, Xu
    Xu, Cailing
    [J]. RSC ADVANCES, 2014, 4 (39) : 20459 - 20465
  • [9] Enhanced non-enzymatic glucose sensing based on copper nanoparticles decorated nitrogen-doped graphene
    Jiang, Ding
    Liu, Qian
    Wang, Kun
    Qian, Jing
    Dong, Xiaoya
    Yang, Zhenting
    Du, Xiaojiao
    Qiu, Baijing
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 54 : 273 - 278
  • [10] A sensitive nonenzymatic glucose sensor in alkaline media with a copper nanocluster/multiwall carbon nano tube-modified glassy carbon electrode
    Kang, Xinhuang
    Mai, Zhibin
    Zou, Xiaoyong
    Cai, Peixiang
    Mo, Jinyuan
    [J]. ANALYTICAL BIOCHEMISTRY, 2007, 363 (01) : 143 - 150