The distribution of strain in the human cornea

被引:83
作者
Shin, TJ
Vito, RP
Johnson, LW
McCarey, BE
机构
[1] GEORGIA INST TECHNOL,SCH MECH ENGN,ATLANTA,GA 30332
[2] INJE UNIV,DEPT MED ENGN,KYUNGNAM 621749,SOUTH KOREA
[3] EMORY UNIV,DEPT OPHTHALMOL,ATLANTA,GA 30305
关键词
human cornea; mechanical properties; strain; microstructure; model; finite element;
D O I
10.1016/S0021-9290(97)84433-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Experimental data on the mechanics of human cornea is meager and sometimes flawed. Moreover, questions regarding the correct material symmetry and the role of the fibrous microstructure are usually glossed over when mechanical models of the cornea and corneal shape changing procedures are presented. Accordingly, the deformation of 14 intact human corneas was measured for five pressures in the physiologic range (0, 5, 10, 25 and 45 cmH(2)O) by tracking small, self-adherent particles placed on their anterior surfaces. The meridional strains: calculated in five regions assuming axisymmetric deformation, are small, the average strain in the apical region being 1.14% at 45 cmH(2)O. Results also indicate that the strain distribution is unexpectedly nonuniform with statistically significant (p < 0.01, typical) variations between regions and a minimum occurring approximately half-way between apex and limbus. To better understand these results, a finite-element moder (FEM) of the cornea was constructed and used to simulate the experiment. The heterogeneous model shows that our data may reflect the changing fiber orientation along a meridian suggested in the literature. The implications of a link between microstructure and mechanics are discussed in light of clinical procedures, such as radial keratotomy, the outcomes of which are dependent on corneal mechanical properties. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:497 / 503
页数:7
相关论文
共 31 条
[1]  
[Anonymous], REFRACTIVE KERATOTOM
[2]  
BEATTIE DK, 1996, P 4 ANN PRE ORS COMP
[3]   A MODEL FOR ESTIMATING CORNEAL STIFFNESS USING AN INDENTER [J].
CARNELL, PH ;
VITO, RP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (04) :549-552
[4]  
DOHLMAN CH, 1957, ACTA OPHTHALMOL, V35, P79
[5]  
Fan I, 1978, PHYSL EYE INTRO ITS
[6]  
Fung YC., 1981, BIOMECHANICS
[7]  
Hanna K D, 1992, Refract Corneal Surg, V8, P152
[8]   STRIP EXTENSIOMETRY FOR COMPARISON OF THE MECHANICAL RESPONSE OF BOVINE, RABBIT, AND HUMAN CORNEAS [J].
HOELTZEL, DA ;
ALTMAN, P ;
BUZARD, K ;
CHOE, KI .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (02) :202-215
[9]  
HOFFMAN JD, 1984, J BIOMECH, V17, P785
[10]  
Howland H C, 1992, Refract Corneal Surg, V8, P183