Simultaneous quantification of six main active constituents in Chinese Angelica by high-performance liquid chromatography with photodiode array detector

被引:23
|
作者
Li Ying [1 ]
Wang Si-Wang [1 ]
Tu Hong-Hai [2 ]
Cao Wei [1 ]
机构
[1] Fourth Mil Med Univ, Inst Mat Med, Sch Pharm, Xian 710032, Peoples R China
[2] Xinjiang Mil Area Command, Inst Drug & Instrument Control, Urumqi, Xinjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Chinese Angelica; high performance liquid chromatography; photodiode-array detector; quality control; simultaneous determination; COUMARINS; SINENSIS; GIGAS; ROOTS;
D O I
10.4103/0973-1296.111255
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Background: Angelica sinensis is a famous traditional Chinese medicinalherb, which is predominantly used in the treatment of gynecological conditions.It is the first report for the simultaneous determination of six major active components in Chinese Angelica, which is important for quality control. Objective: A validated HPLC-PAD method was first developed to evaluate the quality of crude and processed Radix Angelica through simultaneous determination of six bioactive compounds, namely ferulic acid, senkyunolide I, senkyunolide H, coniferyl ferulate, Z/E-ligustilide and Z/E-butylidenephthalide. Materials and Methods: Samples were separated on a XtimateC 18 column (250 x 4.6 mm, 5 m) and detected by PAD. Mobile phase was composed of (A) aqueous phosphoric acid (0.02%, v/v) and (B) acetonitrile (MeCN) (including 10% tetrahydrofuran, v/v) using a gradient elution. Analytes were performed at 30 degrees C with a flow rate of 1.0 mL/min. Results: All calibration curves showed good linear regression (r (2) >= 0.9963) within the tested ranges, and the recovery of the method was in the range of 91.927-105.859%. Conclusion: The results demonstrate that the developed method is accurate and reproducible and could be readily utilized as a suitable quality control method for the quantification of Radix Angelica.
引用
收藏
页码:114 / 119
页数:6
相关论文
共 50 条
  • [41] Development and validation of an high-performance liquid chromatography-diode array detector method for the simultaneous determination of six phenolic compounds in abnormal savda munziq decoction
    Tian, Shuge
    Liu, Wenxian
    Liu, Feng
    Zhang, Xuejia
    Upur, Halmuart
    PHARMACOGNOSY MAGAZINE, 2015, 11 (41) : 157 - 162
  • [42] Quality control of tuirejieduling granules using high-performance liquid chromatography fingerprint method and simultaneous determination of four main active ingredients
    Yang, Aixia
    Wang, Xiaoxian
    Xiong, Chaomei
    Chen, Jing
    Ruan, Jinlan
    PHARMACOGNOSY MAGAZINE, 2013, 9 (34) : 162 - 166
  • [43] Quantitative Analysis of 18 Marker Components in the Traditional Korean Medicine, Cheongsangbangpung-Tang, Using High-Performance Liquid Chromatography Combined with Photodiode Array Detector
    Seo, Chang-Seob
    Shin, Hyeun-Kyoo
    APPLIED SCIENCES-BASEL, 2021, 11 (01): : 1 - 11
  • [44] High-performance liquid chromatography with photodiode array detection and chemometrics method for the analysis of multiple components in the traditional Chinese medicine Shuanghuanglian oral liquid
    Li, Bao Qiong
    Chen, Jing
    Li, Jiao Jiao
    Wang, Xue
    Zhai, Hong Lin
    Zhang, Xiao Yun
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (24) : 4187 - 4195
  • [45] RAPID DETERMINATION OF OSELTAMIVIR IN CAPSULES BY ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY WITH PHOTODIODE ARRAY DETECTOR
    Antunes, Marina Venzon
    Fraga Griebeler, Barbara Estefania
    Linden, Rafael
    QUIMICA NOVA, 2011, 34 (07): : 1271 - 1274
  • [46] Simultaneous characterization and quantification of 17 main compounds in Rabdosia rubescens by high performance liquid chromatography
    Guo, Sen
    Cui, Xueqin
    Jiang, Mi
    Bai, Lu
    Tian, Xiao
    Guo, Tiantian
    Liu, Qingchao
    Zhang, Li
    Ho, Chi-Tang
    Bai, Naisheng
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2017, 25 (02) : 417 - 424
  • [47] Simultaneous determination of six herbal components in intestinal perfusate by high-performance liquid chromatography
    Wang, Zhanguo
    Du, Qingqing
    Qiu, Xuelan
    Liu, Fang
    Tan, Fei
    Lan, Ke
    Jiang, Xuehua
    Jiang, Qian
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (08) : 798 - 803
  • [48] Determination of Phenylethanolamine A in Animal Feeds Using Ultra High Performance Liquid Chromatography-Photodiode Array Detector
    Wang Rui-Guo
    Su Xiao-Ou
    Wang Pei-Long
    Li Yang
    Fan Yu-Fei
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (03) : 389 - 393
  • [49] Smartphone as a fluorescence detector for high-performance liquid chromatography
    Shamsaei, Danial
    Hsieh, Shu-An
    Ocana-Rios, Iran
    Ryan, Saxon J.
    Anderson, Jared L.
    ANALYTICA CHIMICA ACTA, 2023, 1280
  • [50] Simultaneous Determination of Nine Dyestuffs and Dyes Intermediates in Cosmetics by High Performance Liquid Chromatography/Photodiode Array Detection
    Chen Juan
    Wang Chao
    Wang Xing
    Ma Qiang
    Li Nan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2007, 25 (06) : 867 - 870