Enhancing Trigger Point Dry Needling Safety by Ultrasound Skin-to-Rib Measurement: An inter-Rater Reliability Study

被引:6
作者
Folli, Anna [1 ]
Schneebeli, Alessandro [1 ]
Ballerini, Simone [2 ]
Mena, Francesca
Soldini, Emiliano [3 ,4 ]
Fernandez-de-las-Penas, Cesar [5 ,6 ]
Barbero, Marco [1 ]
机构
[1] Univ Appl Sci & Arts Southern Switzerland, Dept Business Econ Hlth & Social Care, Rehabil Res Lab 2rLab, CH-6928 Manno, Switzerland
[2] Univ Appl Sci & Arts Southern Switzerland, Dept Business Econ Hlth & Social Care, CH-6928 Manno, Switzerland
[3] Res Methodol Competence Ctr, Dept Business Econ Hlth & Social Care, CH-6928 Manno, Switzerland
[4] Univ Appl Sci & Arts Southern Switzerland, CH-6928 Manno, Switzerland
[5] Univ Rey Juan Carlos URJC, Dept Phys Therapy Occupat Therapy Phys Med & Reha, Madrid 28922, Spain
[6] Univ Rey Juan Carlos, Catedra Inst Docencia Clin & Invest Fisioterapia, Madrid 28922, Spain
关键词
trigger points; dry needling; adverse events; safety; skin-to-rib; reliability; ultrasound; MUSCLE THICKNESS; LOWER TRAPEZIUS; ACUPUNCTURE; SIZE;
D O I
10.3390/jcm9061958
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dry needling (DN) is a minimally invasive treatment technique widely used by physical therapists to treat myofascial trigger points (MTrP). Even if its safety has been commonly declared and the majority of adverse events are considered mild, serious adverse events cannot be excluded and DN treatments of several trunk muscles can potentially result in pneumothorax. Ultrasound imaging (US) skin-to-rib measurement could ensure the safety of this treatment procedure. Therefore, the aim of this study was to determine the inter-rater reliability of depth measurement of different trunk muscles (i.e., rhomboid, lower trapezius, iliocostalis, and pectoralis major) between an expert and two novice physiotherapists. Skin-to-rib distance of 26 asymptomatic and normal weights subjects was consecutively, independently, and randomly measured for each muscle by the three examiners (1 expert and 2 novice physical therapists) with a handheld US wireless probe. Intraclass correlation coefficient (ICC3,k) and standard error of measurement (SEM) were used to assess inter-rater reliability. Inter-rater reliability of skin-to-rib measurements between the three examiners was good to excellent or excellent for every muscle, with an ICC(3,k)ranging from 0.92 and 0.98 (95% CI 0.86-0.99). The SEM never exceeded 10% of the skin-to-rib distance. In conclusion, skin-to-rib US measurements of the trunk muscles can be reliably performed by novice physical therapists using a handheld US device. These measures could be used as an innovative and reliable technique to improve the safety of some potential dangerous DN treatments.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 37 条
[1]   ADVERSE EVENTS ASSOCIATED WITH THERAPEUTIC DRY NEEDLING [J].
Boyce, David ;
Wempe, Hannah ;
Campbell, Courtney ;
Fuehne, Spencer ;
Zylstra, Edo ;
Smith, Grant ;
Wingard, Christopher ;
Jones, Richard .
INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2020, 15 (01) :103-113
[2]   Adverse events following trigger point dry needling: a prospective survey of chartered physiotherapists [J].
Brady, Sarah ;
McEvoy, Johnson ;
Dommerholt, Jan ;
Doody, Catherine .
JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2014, 22 (03) :134-140
[3]   THE ASSESSMENT OF METHODS OF MEASUREMENT [J].
CHINN, S .
STATISTICS IN MEDICINE, 1990, 9 (04) :351-362
[4]   Intra- and inter-rater reliabilities of measurement of ultrasound imaging for muscle thickness and pennation angle of tibialis anterior muscle in stroke patients [J].
Cho, Ki Hun ;
Lee, Hwang Jae ;
Lee, Wan Hee .
TOPICS IN STROKE REHABILITATION, 2017, 24 (05) :368-373
[5]   Pneumothorax complication of deep dry needling demonstration [J].
Cummings, M. ;
Ross-Marrs, R. ;
Gerwin, R. .
ACUPUNCTURE IN MEDICINE, 2014, 32 (06) :517-519
[6]   ULTRASOUND VERIFICATION OF SAFE NEEDLE EXAMINATION OF THE RHOMBOID MAJOR MUSCLE [J].
Cushman, Daniel ;
Henrie, Michael ;
Scholl, Linda Vernon ;
Ludlow, Monica ;
Teramoto, Masaru .
MUSCLE & NERVE, 2018, 57 (01) :61-64
[7]  
Dommerholt J, 2018, TRIGGER POINT DRY NE
[8]   Trigger Point Dry Needling [J].
Dommerholt, Jan ;
del Moral, Orlando Mayoral ;
Grobli, Christian .
JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2006, 14 (04) :E70-E87
[9]   Dry needling - peripheral and central considerations [J].
Dommerholt, Jan .
JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2011, 19 (04) :223-237
[10]   Dry needling for the management of thoracic spine pain [J].
Fernandez-de-las-Penas, Cesar ;
Layton, Michelle ;
Dommerholt, Jan .
JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2015, 23 (03) :147-153