Conventional and narrow bore short capillary columns with cyclodextrin derivatives as chiral selectors to speed-up enantioselective gas chromatography and enantioselective gas chromatography-mass spectrometry analyses

被引:21
作者
Bicchi, Carlo [1 ]
Liberto, Erica [1 ]
Cagliero, Cecilia [1 ]
Cordero, Chiara [1 ]
Sgorbini, Barbara [1 ]
Rubiolo, Patrizia [1 ]
机构
[1] Univ Turin, Fac Farm, Dipartimento Sci & Tecnol Farm, I-10125 Turin, Italy
关键词
Fast enantioselective GC-MS; Cyclodextrin derivatives; Linear retention indices; Mass spectra; Flavours; Fragrances;
D O I
10.1016/j.chroma.2008.10.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of complex real-world samples of vegetable origin requires rapid and accurate routine methods, enabling laboratories to increase sample throughput and productivity while reducing analysis costs. This study examines shortening enantioselective-GC (ES-GC) analysis time following the approaches used in fast GC. ES-GC separations are due to a weak enantiomer-CD host-guest interaction and the separation is thermodynamically driven and strongly influenced by temperature. As a consequence, fast temperature rates can interfere with enantiomeric discrimination: thus the use of short and/or narrow bore columns is a possible approach to speeding-up ES-GC analyses. The performance of ES-GC with a conventional inner diameter (I.D.) column (25 m length x 0.25 mm I.D., 0.15 mu m and 0.25 mu m d(f)) coated with 30% of 2,3-di-O-ethyl-6-O-tert-butyldimethylsilyl-beta-cyclodextrin in PS-086 is compared to those of conventional I.D. short column (5 m length x 0.25 mm I.D., 0.15 mu m d(f)) and of different length narrow bore columns (1, 2, 5 and 10 m long x 0.10 mm I.D., 0.10 mu m d(f)) in analysing racemate standards of pesticides and in the flavour and fragrance field and real-world-samples. Short conventional I.D. columns gave shorter analysis time and comparable or lower resolutions with the racemate standards, depending mainly on analyte volatility. Narrow-bore columns were tested under different analysis conditions; they provided shorter analysis time and resolutions comparable to those of conventional I.D. ES columns. The narrow-bore columns offering the most effective compromise between separation efficiency and analysis time are the 5 and 2 m columns; in combination with mass spectrometry as detector, applied to lavender and bergamot essential oil analyses. these reduced analysis time by a factor of at least three while separation of chiral markers remained unaltered. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 123
页数:10
相关论文
共 31 条
[1]   DETERMINATION OF THE ENANTIOMERIC COMPOSITION OF GAMMA-LACTONES IN COMPLEX NATURAL MATRICES USING MULTIDIMENSIONAL CAPILLARY GAS-CHROMATOGRAPHY [J].
BERNREUTHER, A ;
CHRISTOPH, N ;
SCHREIER, P .
JOURNAL OF CHROMATOGRAPHY, 1989, 481 :363-367
[2]   CYCLODEXTRIN DERIVATIVES IN GC SEPARATION OF RACEMIC MIXTURES OF VOLATILES .3. [J].
BICCHI, C ;
ARTUFFO, G ;
DAMATO, A ;
GALLI, A ;
GALLI, M .
CHIRALITY, 1992, 4 (02) :125-131
[3]   Cyclodextrin derivatives in the gas chromatographic separation of racemic mixtures of volatile compounds .10. 2,3-Di-O-ethyl-6-O-tert-butyldimethylsilyl-beta- and -gamma-cyclodextrins [J].
Bicchi, C ;
DAmato, A ;
Manzin, V ;
Galli, A ;
Galli, M .
JOURNAL OF CHROMATOGRAPHY A, 1996, 742 (1-2) :161-173
[4]  
BICCHI C, 1992, HRC-J HIGH RES CHROM, V15, P710
[5]  
BICCHI C, 1991, 2 INT S CHIR DISCR R
[6]   Metrics of separation in chromatography [J].
Blumberg, LM ;
Klee, MS .
JOURNAL OF CHROMATOGRAPHY A, 2001, 933 (1-2) :1-11
[7]   High-speed gas chromatography: an overview of various concepts [J].
Cramers, CA ;
Janssen, HG ;
van Deursen, MM ;
Leclercq, PA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :315-329
[8]   Instrumentation and applications of fast high-resolution capillary gas chromatography [J].
David, F ;
Gere, DR ;
Scanlan, F ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :309-319
[9]   Possibilities and limitations of fast GC with narrow-bore columns [J].
Domotorova, Milena ;
Kirchner, Michal ;
Matisova, Eva ;
de Zeeuw, Jaap .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (08) :1051-1063
[10]   GAS-CHROMATOGRAPHIC ENANTIOMER SEPARATION OF BROMOCHLOROFLUOROMETHANE [J].
GROSENICK, H ;
SCHURIG, V ;
COSTANTE, J ;
COLLET, A .
TETRAHEDRON-ASYMMETRY, 1995, 6 (01) :87-88