Effect of simulated brushing and disinfection on the surface roughness and color stability of CAD-CAM denture base materials

被引:8
作者
Cakmak, Guelce [1 ]
Donmez, Mustafa Borga [1 ,2 ,8 ]
Akay, Canan [3 ]
Atalay, Sevda
de Paula, Marcella Silva [1 ,4 ]
Schimmel, Martin [1 ,5 ]
Yilmaz, Burak [1 ,6 ,7 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[2] Istinye Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey
[3] Osmangazi Univ, Fac Dent, Dept Prosthodont, Eskisehir, Turkey
[4] Univ Fed Goias, Dept Prevent & Oral Rehabil, Goiania, GO, Brazil
[5] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[6] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[7] Ohio State Univ, Div Restorat & Prosthet Dent, Coll Dent, Columbus, OH USA
[8] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
关键词
CAD-CAM; Color stability; Denture base; Disinfection; Simulated brushing; Surface roughness; MICROWAVE; HARDNESS; RESIN;
D O I
10.1016/j.jmbbm.2022.105390
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: To evaluate the effect of simulated brushing and chemical disinfection on the surface roughness and color stability of CAD-CAM denture base materials and to compare with those of a heat-cured denture base material.Material and methods: Disk-shaped specimens (O 10mm x 2 mm) were prepared from 3 CAD-CAM denture base resins (AvaDent, Ava; Merz M-PM, Merz; Polident d.o.o, Poli) and a heat-cured polymethylmethacrylate resin (Promolux, Conv) (n = 30). After polishing, baseline surface roughness (Ra) and color coordinates were measured. The measurements were repeated after 20000 cycles of simulated brushing, and the specimens were divided into 3 groups according to disinfection protocol (distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet) (n = 10). After 9 cleaning cycles over a period of 20 days, Ra and color coordinates were remeasured. Color differences (Delta E00) were calculated by using CIEDE2000 formula. One-way analysis of vari-ance (ANOVA) and pairwise t-tests were used to analyze Ra and Delta E00 data, while repeated measures ANOVA test was used to compare baseline, after brush, and after disinfection Ra values (alpha = 0.05).Results: Brushing did not affect the Ra values of tested materials (P >= .08). Both before and after brushing, Merz and Conv had higher Ra values than Poli and Ava (P < .001). Among disinfectants, effervescent tablet led to the lowest Ra for Merz (P = .003) and the highest Ra for Poli (P < .039). Only NaOCl resulted in significant dif-ferences among the Ra of materials (P < .001), as Merz and Conv had higher Ra values than Poli (P < .002). Repeated measures ANOVA revealed that effervescent tablet disinfection of Merz led to lower Ra values than those of baseline and after brushing (P < .042). After brushing, Ava and Conv had higher Delta E00 values compared with Merz and Poli (P < .015). When compared with other disinfection protocols, effervescent tablet led to higher Delta E00 values for Merz and Poli (P < .001). Significant differences were observed among materials when NaOCl was used; Conv had higher Delta E00 values than Ava and Merz (P = .004).Conclusions: Brushing did not increase the surface roughness of materials. Disinfection protocol's effect on the surface roughness varied. The effect of brushing on the color of materials varied; color of Ava and Conv was affected from brushing more than the other materials. Color stability of materials varied depending on the disinfection protocol. Effervescent tablet caused higher color change with Merz and Poli compared with other disinfectants. NaOCl led to small color change for Poli, Ava, and Merz materials.
引用
收藏
页数:7
相关论文
共 37 条
[21]   Effect of toothbrushing, chemical disinfection and thermocycling procedures on the surface microroughness of denture base acrylic resins [J].
Lira, Andrea F. ;
Consani, Rafael L. X. ;
Mesquita, Marcelo F. ;
Nobilo, Mauro A. A. ;
Henriques, Guilherme E. P. .
GERODONTOLOGY, 2012, 29 (02) :E891-E897
[22]   Activated charcoal toothpastes do not increase erosive tooth wear [J].
Lira Viana, Itallo Emidio ;
Weiss, Guilherme Stangler ;
Sakae, Leticia Oba ;
Niemeyer, Samira Helena ;
Borges, Alessandra Buhler ;
Scaramucci, Tais .
JOURNAL OF DENTISTRY, 2021, 109 :103677
[23]  
Livas C, 2020, J OROFAC ORTHOP, V81, P22, DOI 10.1007/s00056-019-00200-x
[24]  
Masetti P, 2018, J PROSTHET DENT, V120
[25]   Effect of cleansers on denture base resins' structural properties [J].
Ozyilmaz, Ozgun Yusuf ;
Akin, Ceyda .
JOURNAL OF APPLIED BIOMATERIALS & FUNCTIONAL MATERIALS, 2019, 17 (01)
[26]  
Paranhos Helena de Freitas Oliveira, 2013, Braz. Dent. J., V24, P152, DOI 10.1590/0103-6440201302151
[27]   Long-term microwaving of denture base materials: effects on dimensional, color and translucency stability [J].
Polychronakis, Nick ;
Polyzois, Gregory ;
Lagouvardos, Panagiotis ;
Andreopoulos, Andreas ;
Ngo, Hien Chi .
JOURNAL OF APPLIED ORAL SCIENCE, 2018, 26
[28]  
Porwal Anand, 2017, J Indian Prosthodont Soc, V17, P61, DOI 10.4103/0972-4052.197940
[29]   Acrylic resins in the CAD/CAM technology: A systematic literature review [J].
Raszewski, Zbigniew .
DENTAL AND MEDICAL PROBLEMS, 2020, 57 (04)
[30]   Determining color difference thresholds in denture base acrylic resin [J].
Ren, Jiabao ;
Lin, Hong ;
Huang, Qingmei ;
Zheng, Gang .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (05) :702-708