Effect of simulated brushing and disinfection on the surface roughness and color stability of CAD-CAM denture base materials

被引:8
作者
Cakmak, Guelce [1 ]
Donmez, Mustafa Borga [1 ,2 ,8 ]
Akay, Canan [3 ]
Atalay, Sevda
de Paula, Marcella Silva [1 ,4 ]
Schimmel, Martin [1 ,5 ]
Yilmaz, Burak [1 ,6 ,7 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[2] Istinye Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey
[3] Osmangazi Univ, Fac Dent, Dept Prosthodont, Eskisehir, Turkey
[4] Univ Fed Goias, Dept Prevent & Oral Rehabil, Goiania, GO, Brazil
[5] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[6] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[7] Ohio State Univ, Div Restorat & Prosthet Dent, Coll Dent, Columbus, OH USA
[8] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
关键词
CAD-CAM; Color stability; Denture base; Disinfection; Simulated brushing; Surface roughness; MICROWAVE; HARDNESS; RESIN;
D O I
10.1016/j.jmbbm.2022.105390
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: To evaluate the effect of simulated brushing and chemical disinfection on the surface roughness and color stability of CAD-CAM denture base materials and to compare with those of a heat-cured denture base material.Material and methods: Disk-shaped specimens (O 10mm x 2 mm) were prepared from 3 CAD-CAM denture base resins (AvaDent, Ava; Merz M-PM, Merz; Polident d.o.o, Poli) and a heat-cured polymethylmethacrylate resin (Promolux, Conv) (n = 30). After polishing, baseline surface roughness (Ra) and color coordinates were measured. The measurements were repeated after 20000 cycles of simulated brushing, and the specimens were divided into 3 groups according to disinfection protocol (distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet) (n = 10). After 9 cleaning cycles over a period of 20 days, Ra and color coordinates were remeasured. Color differences (Delta E00) were calculated by using CIEDE2000 formula. One-way analysis of vari-ance (ANOVA) and pairwise t-tests were used to analyze Ra and Delta E00 data, while repeated measures ANOVA test was used to compare baseline, after brush, and after disinfection Ra values (alpha = 0.05).Results: Brushing did not affect the Ra values of tested materials (P >= .08). Both before and after brushing, Merz and Conv had higher Ra values than Poli and Ava (P < .001). Among disinfectants, effervescent tablet led to the lowest Ra for Merz (P = .003) and the highest Ra for Poli (P < .039). Only NaOCl resulted in significant dif-ferences among the Ra of materials (P < .001), as Merz and Conv had higher Ra values than Poli (P < .002). Repeated measures ANOVA revealed that effervescent tablet disinfection of Merz led to lower Ra values than those of baseline and after brushing (P < .042). After brushing, Ava and Conv had higher Delta E00 values compared with Merz and Poli (P < .015). When compared with other disinfection protocols, effervescent tablet led to higher Delta E00 values for Merz and Poli (P < .001). Significant differences were observed among materials when NaOCl was used; Conv had higher Delta E00 values than Ava and Merz (P = .004).Conclusions: Brushing did not increase the surface roughness of materials. Disinfection protocol's effect on the surface roughness varied. The effect of brushing on the color of materials varied; color of Ava and Conv was affected from brushing more than the other materials. Color stability of materials varied depending on the disinfection protocol. Effervescent tablet caused higher color change with Merz and Poli compared with other disinfectants. NaOCl led to small color change for Poli, Ava, and Merz materials.
引用
收藏
页数:7
相关论文
共 37 条
[1]   A Comparison of the Surface Properties of CAD/CAM and Conventional Polymethylmethacrylate (PMMA) [J].
Al-Dwairi, Ziad N. ;
Tahboub, Kawkab Y. ;
Baba, Nadim Z. ;
Goodacre, Charles J. ;
Ozcan, Mutlu .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (04) :452-457
[2]   Stainability of acrylic resin materials used in CAD-CAM and conventional complete dentures [J].
al-Qarni, Faisal D. ;
Goodacre, Charles J. ;
Kattadiyil, Mathew T. ;
Baba, Nadim Z. ;
Paravina, Rade D. .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (06) :880-887
[3]   Surface roughness analysis of prepolymerized CAD/CAM dental acrylic resins following combined surface treatments [J].
Alfouzan, Afnan ;
Alnouwaisar, Alhanouf ;
Alazzam, Njood ;
AL-Otaibi, Hanan ;
Labban, Nawaf ;
Alswaidan, Mashaal ;
Al-Taweel, Sara ;
Alshehri, Huda .
MATERIALS SCIENCE-POLAND, 2021, 39 (02) :209-218
[4]   Power brushing and chemical denture cleansers induced color changes of pre-polymerized CAD/CAM denture acrylic resins [J].
Alfouzan, Afnan F. ;
AlNouwaisar, Alhanouf N. ;
AlAzzam, Njood F. ;
Al-Otaibi, Hanan N. ;
Labban, Nawaf ;
Alswaidan, Mashaal H. ;
Al Taweel, Sara M. ;
Alshehri, Huda A. .
MATERIALS RESEARCH EXPRESS, 2021, 8 (08)
[5]   Effect of aging and mechanical brushing on surface roughness of 3D printed denture resins: A profilometer and scanning electron microscopy analysis [J].
Alfouzan, Afnan F. ;
Alotiabi, Hadeel M. ;
Labban, Nawaf ;
Al-Otaibi, Hanan N. ;
Al Taweel, Sara Mohammad ;
AlShehri, Huda A. .
TECHNOLOGY AND HEALTH CARE, 2022, 30 (01) :161-173
[6]   Color stability of 3D-printed denture resins: effect of aging, mechanical brushing and immersion in staining medium [J].
Alfouzan, Afnan Fouzan ;
Alotiabi, Hadeel Minife ;
Labban, Nawaf ;
Al-Otaibi, Hanan Nejer ;
Al Taweel, Sara Mohammad ;
AlShehri, Huda Ahmed .
JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (03) :160-171
[7]   Optical properties and surface roughness of prepolymerized poly(methyl methacrylate) denture base materials [J].
Alp, Gulce ;
Johnston, William M. ;
Yilmaz, Burak .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (02) :347-352
[8]  
Arruda Carolina Noronha Ferraz, 2015, Braz. Dent. J., V26, P404, DOI 10.1590/0103-6440201300120
[9]  
Arslan M, 2018, INT J COMPUT DENT, V21, P31
[10]   Effect of different disinfection protocols on the surface properties of CAD-CAM denture base materials [J].
Atalay, Sevda ;
Cakmak, Gulce ;
Fonseca, Manrique ;
Schimmel, Martin ;
Yilmaz, Burak .
JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (05) :787-795