Tidal Water Effect on the Hybrid Cathodic Protection Systems for Marine Concrete Structures

被引:12
|
作者
Jeong, Jin-A [1 ]
Jin, Chung-Kuk [2 ]
Chung, Won-Sub [3 ]
机构
[1] Korea Maritime Univ, Sea Training Ctr, Pusan, South Korea
[2] Korea Maritime Univ, Dept Marine Syst Engn, Pusan, South Korea
[3] Pusan Natl Univ, Dept Mat Engn, Pusan, South Korea
关键词
REINFORCED-CONCRETE; SACRIFICIAL ANODES; PREVENTION;
D O I
10.3151/jact.10.389
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper represents the behaviors of hybrid cathodic protection (hybrid CP) system in a reinforced concrete column specimen. Cathodic protection (CP) is widely used as a means of protecting corrosion for marine concrete structures such as harbor and offshore facilities. Specifically, hybrid CP, which is the combination both sacrificial anode cathodic protection (SACP) system and impressed current cathodic protection (ICCP) system, can be an optimum way to protect corrosion. Some complex concrete structures as well as harbor constructions are considered to be protected by both systems. Especially, it becomes more complicated to protect corrosion damage of concrete structures in the tidal and splash zones of marine environment. In case of Yellow Sea of the South Korea, the tidal zone reaches to 6 similar to 8m. On the condition that this system is well applied in the Yellow Sea, it is expected to show a good CP behavior to solve an under-protection problem, especially in tidal and splash zones. In this study, the hybrid system installed both the ICCP with Timesh anode and the SACP with zinc anode has been adopted to verify the current influence through laboratory experiment. CP potential and current have been investigated, in addition, 4-hour depolarization test has been involved to reveal the effectiveness of hybrid CP.
引用
收藏
页码:389 / 394
页数:6
相关论文
共 30 条
  • [21] Dual function carbon fibre fabric strengthening and impressed current cathodic protection (ICCP) anode for reinforced concrete structures
    Paul Lambert
    Chinh Van Nguyen
    Pritpal S. Mangat
    Finbar J. O’Flaherty
    Graeme Jones
    Materials and Structures, 2015, 48 : 2157 - 2167
  • [22] Effect of Wet Curing Duration on Long-Term Performance of Concrete in Tidal Zone of Marine Environment
    Khanzadeh-Moradllo, Mehdi
    Meshkini, Mohammad H.
    Eslamdoost, Ehsan
    Sadati, Seyedhamed
    Shekarchi, Mohammad
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2015, 9 (04) : 487 - 498
  • [23] Development of Conductive Mortar for Efficient Sacrificial Anode Cathodic Protection of Reinforced Concrete Structures-Part 1: Laboratory Experiments
    Ha, Ji-Myung
    Jeong, Jin-A
    Jin, Chungkuk
    APPLIED SCIENCES-BASEL, 2022, 12 (23):
  • [24] STUDY AND APPLICATION OF IMPRESSED CURRENT CATHODIC PROTECTION TECHNIQUE FOR ATMOSPHERICALLY EXPOSED SALT-CONTAMINATED REINFORCED-CONCRETE STRUCTURES
    HONG, DH
    FAN, WG
    LUO, DK
    GE, Y
    ZHU, YX
    ACI MATERIALS JOURNAL, 1993, 90 (01) : 3 - 7
  • [25] Effect of macrocell currents on rebar corrosion in reinforced concrete structures exposed to a marine environment
    Lliso-Ferrando, J. R.
    Gasch, I.
    Martinez-Ibernon, A.
    Valcuende, M.
    OCEAN ENGINEERING, 2022, 257
  • [26] Efficiency of surface protection systems for concrete: water absorption, chloride migration and contact angle
    Farias de Medeiros, Marcelo Henrique
    Pereira, Eduardo
    Figura, Andrielli Scardanzan
    Tissot, Felipe Maues
    Artioli, Karen Alves
    MATERIA-RIO DE JANEIRO, 2015, 20 (01): : 145 - 159
  • [27] A galvanic sensor system for detecting the corrosion damage of the steel embedded in concrete structures: Laboratory tests to determine the cathodic protection and stray-current
    Yoo, Yun-Ha
    Nam, Tae-Heum
    Choi, Yoon-Seok
    Kim, Jung-Gu
    Chung, Lan
    METALS AND MATERIALS INTERNATIONAL, 2011, 17 (04) : 623 - 629
  • [28] A galvanic sensor system for detecting the corrosion damage of the steel embedded in concrete structures: Laboratory tests to determine the cathodic protection and stray-current
    Yun-Ha Yoo
    Tae-Heum Nam
    Yoon-Seok Choi
    Jung-Gu Kim
    Lan Chung
    Metals and Materials International, 2011, 17 : 623 - 629
  • [29] Prediction model of long-term chloride diffusion into plain concrete considering the effect of the heterogeneity of materials exposed to marine tidal zone
    Wang, Yuanzhan
    Wu, Linjian
    Wang, Yuchi
    Li, Qingmei
    Xiao, Zhong
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 159 : 297 - 315
  • [30] Development of Conductive Mortar for Efficient Sacrificial Anode Cathodic Protection of Reinforced Concrete Structures-Part 2: Four-Year Performance Evaluation in Bridges
    Ha, Ji-Myung
    Jeong, Jin-A
    Jin, Chungkuk
    APPLIED SCIENCES-BASEL, 2024, 14 (05):