Measurements of ultrasonic pulse distortion produced by human chest wall

被引:46
作者
Hinkelman, LM
Szabo, TL
Waag, RC
机构
[1] UNIV ROCHESTER,DEPT ELECT ENGN,ROCHESTER,NY 14627
[2] HEWLETT PACKARD IMAGING SYST,ANDOVER,MA 01810
[3] UNIV ROCHESTER,DEPT RADIOL,ROCHESTER,NY 14627
关键词
PHASE-ABERRATION CORRECTION; TIME-SHIFT COMPENSATION; WAVE-FRONT DISTORTION; ARRIVAL TIME; INVIVO MEASUREMENTS; DIFFUSE SCATTERERS; MAMMALIAN-TISSUES; POINT REFLECTORS; BASIC PRINCIPLES; BEAM DISTORTION;
D O I
10.1121/1.418248
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasonic wavefront distortion produced by transmission through human chest wall specimens was measured over a two-dimensional aperture. Measured pulse wavefronts were sometimes disrupted by secondary wavefronts produced by interaction between the transmitted pulses and the bone and cartilage structures of the rib cage. The secondary wavefronts produced large distortions in the received waveforms and interfered with the determination of the wavefront distortion caused by soft-tissue inhomogeneities. The effects of secondary wavefronts were minimized by reducing the region of analysis. Differences in arrival time and energy level between these restricted regions and references that account for geometric delay and spreading were computed. Spectral changes were assessed by calculating a waveform similarity factor that is decreased from 1.0 by changes in waveform shape. For 16 different intercostal spaces, the arrival time fluctuations of the measured waveforms had an average (+/-s.d.) rms value of 21.3 (+/-8.4) ns and an average correlation length of 2.50 (+/-0.62) mm. The energy level fluctuations had an average rms value of 1.57 (+/-0.45) dB and an average correlation length of 1.98 (+/-0.33) mm, and the average waveform similarity factor was 0.964 (+/-0.012). For soft-tissue inhomogeneities in chest wall specimens, the average rms arrival time and energy level fluctuations were less than half those measured for the abdominal wall. However, although the average correlation length of the arrival time fluctuations was less than half that found for the abdominal wall, the average correlation length of the energy level fluctuations was similar to that of the abdominal wall. (C) 1997 Acoustical Society of America.
引用
收藏
页码:2365 / 2373
页数:9
相关论文
共 25 条
  • [1] Chan K L, 1991, J Am Soc Echocardiogr, V4, P577
  • [2] SAFETY OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY - A MULTICENTER SURVEY OF 10,419 EXAMINATIONS
    DANIEL, WG
    ERBEL, R
    KASPER, W
    VISSER, CA
    ENGBERDING, R
    SUTHERLAND, GR
    GRUBE, E
    HANRATH, P
    MAISCH, B
    DENNIG, K
    SCHARTL, M
    KREMER, P
    ANGERMANN, C
    ILICETO, S
    CURTIUS, JM
    MUGGE, A
    [J]. CIRCULATION, 1991, 83 (03) : 817 - 821
  • [3] DUCK FA, 1990, PHYSICAL PROPERTIES
  • [4] FEARNSIDE J, 1993, CARDIOVASCULAR IMAGI
  • [5] FEIGENBAUM H, 1994, ECHOCARDIOGRAPHY, pCH2
  • [6] TIME-REVERSAL OF ULTRASONIC FIELDS .1. BASIC PRINCIPLES
    FINK, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (05) : 555 - 566
  • [7] PHASE-ABERRATION CORRECTION USING SIGNALS FROM POINT REFLECTORS AND DIFFUSE SCATTERERS - BASIC PRINCIPLES
    FLAX, SW
    ODONNELL, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (06) : 758 - 767
  • [8] 2-DIMENSIONAL ULTRASONIC BEAM DISTORTION IN THE BREAST - INVIVO MEASUREMENTS AND EFFECTS
    FREIBURGER, PD
    SULLIVAN, DC
    LEBLANC, BH
    SMITH, SW
    TRAHEY, GE
    [J]. ULTRASONIC IMAGING, 1992, 14 (04) : 398 - 414
  • [9] GERLOCK AJ, 1988, APPL NONINVASIVE VAS, P64
  • [10] COMPILATION OF EMPIRICAL ULTRASONIC PROPERTIES OF MAMMALIAN-TISSUES .2.
    GOSS, SA
    JOHNSTON, RL
    DUNN, F
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1980, 68 (01) : 93 - 108