The effect of the number of iterative restorations on tuned aperture computed tomography for approximal caries detection

被引:8
作者
Abreu, M [1 ]
Tyndall, DA [1 ]
Ludlow, JB [1 ]
Nortjé, CJ [1 ]
机构
[1] Univ Fed Santa Catarina, Sch Dent, Dept Stomatol, Florianopolis, SC, Brazil
关键词
tomography; X-ray computed; image enhancement; computer-assisted; dental caries; diagnosis;
D O I
10.1038/sj.dmfr.4600636
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To determine whether the number of iterative restorations performed on TACT(R) images affects observers' ability to detect dental caries. Methods: Eight TACT(R) basis images of 40 extracted human posterior teeth were acquired using a CCD sensor. TACT(R) slices of each tooth were generated and subsequently submitted to 1, 2 or 3 iterative restorations. Stacks of images from the three experimental conditions were presented to six observers in a balanced order, on a high-resolution 21' color monitor. Observers scored the presence or absence of approximal caries using a 5-point confidence scale. Observers' assessments were compared with the results of histological examination. Receiver operating characteristic (ROC) curves were generated and possible significant differences between observers and between modalities tested by ANOVA. The level of significance was set at alpha =0.05. Interobserver reliability was calculated as intraclass correlation. Results: Mean areas under the ROC curves (A(2)) for the three experimental conditions were 0.791 (one iterative restoration), 0.81 (two iterative restorations), and 0.778 (three iterative restorations). ANOVA did not demonstrate any significant difference between modalities (P=0.25) but did so between observers (P=0.031). Interobserver reliability was similar for all experimental conditions tested. Conclusions: Varying the number of iterative restorations from one to three does not affect observers' ability to detect approximal caries with TACT(R) slices.
引用
收藏
页码:325 / 329
页数:5
相关论文
共 23 条
  • [1] Two- and three-dimensional imaging modalities for the detection of caries.: A comparison between film, digital radiography and tuned aperture computed tomography (TACT™)
    Abreu, M
    Tyndall, DA
    Platin, E
    Ludlow, JB
    Phillips, C
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (03) : 152 - 157
  • [2] ITERATIVE 3-DIMENSIONAL IMAGE-RECONSTRUCTION FROM TOMOGRAPHIC PROJECTIONS
    COLSHER, JG
    [J]. COMPUTER GRAPHICS AND IMAGE PROCESSING, 1977, 6 (06): : 513 - 537
  • [3] DESPLANTES BGZ, 1973, EXCERPTA MED, P129
  • [4] ECTOMOGRAPHY - A NEW RADIOGRAPHIC METHOD FOR REPRODUCING A SELECTED SLICE OF VARYING THICKNESS
    EDHOLM, P
    GRANLUND, G
    KNUTSSON, H
    PETERSSON, C
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1980, 21 (04): : 433 - 442
  • [6] COMPUTERIZED TOMOSYNTHESIS OF DENTAL-TISSUES
    GROENHUIS, RAJ
    WEBBER, RL
    RUTTIMANN, UE
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1983, 56 (02): : 206 - 214
  • [7] GROENHUIS RAJ, 1984, IEEE INT S MED IMAGE, P218
  • [8] TOMOSYNTHESIS AND CODED APERTURE IMAGING - NEW APPROACHES TO 3-DIMENSIONAL IMAGING IN DIAGNOSTIC RADIOGRAPHY
    GROH, G
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1977, 195 (1119): : 299 - +
  • [9] DIGITAL TOMOSYNTHESIS - TECHNIQUE FOR ELECTRONIC RECONSTRUCTIVE TOMOGRAPHY
    MARAVILLA, KR
    MURRY, RC
    HORNER, S
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (03) : 497 - 502
  • [10] TOMOSYNTHESIS-3-D X-RAY IMAGING BY MEANS OF HOLOGRAPHY OR ELECTRONICS
    MEYEREBRECHT, D
    WEISS, H
    [J]. OPTICA ACTA, 1977, 24 (04): : 293 - 303