Rocking wall-frame structures with supplemental tendon systems

被引:145
作者
Ajrab, JJ
Pekcan, G
Mander, JB
机构
[1] Totten Sims Hubicki Associates, Ottawa, ON K2M 2C4, Canada
[2] Univ Nevada, Reno, NV 89557 USA
[3] Univ Canterbury, Dept Civil Engn, Christchurch 1, New Zealand
关键词
shear walls; tendons; energy dissipation; damping; frames;
D O I
10.1061/(ASCE)0733-9445(2004)130:6(895)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper introduces the implementation of proposed rocking shear walls-as opposed to conventional fixed-based walls-in frame structures following the principles of the damage avoidance design philosophy. For improved seismic response, rocking walls are coupled with a separate nonload bearing nonlinear supplemental damping system. In view of the typical response of rocking systems, it is proposed that an energy dissipation system is configured and devices are strategically placed to exploit the expected large displacements. A performance-based design methodology is introduced and used to design a six-story rocking wall-frame building with various supplemental system configurations which include prestressed tendons and energy dissipation devices. Seismic performance and response evaluation, using nonlinear time-history analyses, suggests that desired performance levels (minor to no damage) can be achieved with added equivalent viscous damping (similar to20%) resulting in reduced floor accelerations interstory drifts. Finally, a sensitivity study on the effect of various system parameters on the performance of the structure showed that the seismic response was not sensitive to the prestress level in tendons and to wall base width. Whereas a draped tendon profile results in a lower and more even distribution of interstory drifts in comparison to those in fixed-based structures.
引用
收藏
页码:895 / 903
页数:9
相关论文
共 19 条
[1]  
AJRAB JJ, 2000, THESIS STATE U NEW Y
[2]  
[Anonymous], 1997, NEHRP GUID SEISM REH
[3]  
ASLAM M, 1980, J STRUCT DIV-ASCE, V106, P377
[4]   Experimental verification of basic analytical assumptions used in the analysis of structural wall buildings [J].
Boroschek, RL ;
Yáñez, FV .
ENGINEERING STRUCTURES, 2000, 22 (06) :657-669
[5]  
Goodsir W.J., 1985, DESIGN COUPLED FRAME
[6]  
Housner G.W., 1963, Bull. Seismol. Soc. Am, V53, P403, DOI [10.1785/BSSA0530020403, DOI 10.1785/BSSA0530020403]
[7]  
KURAMA Y, 1998, 9803 LEH U
[8]  
Mander J. B., 1997, NCEER970014 NAT CTR
[9]  
MANDER JB, 1998, P US IT WORKSH SEISM, P335
[10]  
MEEK JW, 1975, J STRUCT DIV-ASCE, V101, P1297