Optimization of the arthroscopic indentation instrument for the measurement of thin cartilage stiffness

被引:42
作者
Lyyra-Laitinen, T
Niinimäki, M
Töyräs, J
Lindgren, R
Kiviranta, I
Jurvelin, JS
机构
[1] Univ Kuopio, Dept Anat, FIN-70211 Kuopio, Finland
[2] Kuopio Univ Hosp, Dept Clin Physiol & Nucl Med, SF-70210 Kuopio, Finland
[3] CSC Ctr Sci Comp, Espoo, Finland
[4] Jyvaskyla Cent Hosp, Dept Surg, Jyvaskyla, Finland
关键词
D O I
10.1088/0031-9155/44/10/310
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Structural alterations associated with early, mostly reversible, degeneration of articular cartilage induce tissue softening, generally preceding fibrillation and, thus, visible changes of the cartilage surface. We have already developed an indentation instrument for measuring arthroscopic stiffness of cartilage with typical thickness >2 mm. The aim of this study was to extend the applicability of the instrument for the measurement of thin (>2 mm) cartilage stiffness. Variations in cartilage thickness, which will nor be known during arthroscopy, can nonetheless affect the indentation measurement, and therefore optimization of the indenter dimensions is necessary. First, we used theoretical and finite element models to compare plane-ended and spherical-ended indenters and, then, altered the dimensions to determine the optimal indenter for thin cartilage measurements. Finally, we experimentally validated the optimized indenter using bovine humeral head cartilage. Reference unconfined compression measurements were carried out with a material testing device. The spherical-ended indenter was more insensitive to the alterations in cartilage thickness (20% versus 39% in the thickness range 1.5-5 mm) than the plane-ended indenter. For thin cartilage, the optimal dimensions for the spherical-ended indenter were 0.5 mm for diameter and 0.1 mm for height. The experimental stiffness measurements with this indenter correlated well with the reference measurements (r = 0.811, n = 31, p < 0.0001) in the cartilage thickness range 0.7-1.8 mm, We conclude that the optimized indenter is reliable and well suited for the measurement of thin cartilage stiffness.
引用
收藏
页码:2511 / 2524
页数:14
相关论文
共 32 条
[1]  
ATHANASIOU KA, 1995, Patent No. 5673708
[2]   MRI contrast enhanced study of cartilage proteoglycan degradation in the rabbit knee [J].
Bacic, G ;
Liu, KJ ;
Goda, F ;
Hoopes, PJ ;
Rosen, GM ;
Swartz, HM .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) :764-768
[3]   NONDESTRUCTIVE DETECTION OF CARTILAGE DEGENERATION USING ELECTROMECHANICAL SURFACE SPECTROSCOPY [J].
BERKENBLIT, SI ;
FRANK, EH ;
SALANT, EP ;
GRODZINSKY, AJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (04) :384-392
[4]   TREATMENT OF DEEP CARTILAGE DEFECTS IN THE KNEE WITH AUTOLOGOUS CHONDROCYTE TRANSPLANTATION [J].
BRITTBERG, M ;
LINDAHL, A ;
NILSSON, A ;
OHLSSON, C ;
ISAKSSON, O ;
PETERSON, L .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (14) :889-895
[5]  
Chu CR, 1997, CLIN ORTHOP RELAT R, P220
[6]  
Dashefsky J H, 1987, Arthroscopy, V3, P80, DOI 10.1016/S0749-8063(87)80021-X
[7]   T-1 rho-relaxation in articular cartilage: Effects of enzymatic degradation [J].
Duvvuri, U ;
Reddy, R ;
Patel, SD ;
Kaufman, JH ;
Kneeland, JB ;
Leigh, JS .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :863-867
[8]   Chondrocyte transplantation using a collagen bilayer matrix for cartilage repair [J].
Frenkel, SR ;
Toolan, B ;
Menche, D ;
Pitman, MI ;
Pachence, JM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (05) :831-836
[9]  
FU FH, 1998, 2 S INT CART REP SOC
[10]   ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270