Analysis and implementation of a three-phase power factor correction scheme using modular Cuk rectifier for balanced and unbalanced supply conditions

被引:3
作者
Umamaheswari, Mallapu Gopinath [1 ,2 ]
Uma, Govindarajan [1 ]
Viswanathan, Sangeetha [3 ]
机构
[1] Anna Univ, Dept Elect & Elect Engn, Coll Engn, Madras 600025, Tamil Nadu, India
[2] RMK Engn Coll, Dept Elect & Instrumentat Engn, Kavaraipettai 601206, Tamil Nadu, India
[3] Amrita Univ, Dept Elect & Elect Engn, Coimbatore 641112, Tamil Nadu, India
关键词
AC-DC power convertors; DC-DC power convertors; electric current control; load regulation; PI control; power factor correction; voltage control; three-phase power factor correction; modular Cuk rectifier; balanced supply conditions; unbalanced supply conditions; three-phase ACaEuro"DC converter; DCaEuro"DC Cuk converter modules; unity power factor; reference current generation techniques; symmetrical component theory; extended synchronous detection methods; equal power criterion; equal current criterion; impedance criterion; reference current generation; control strategy; three hysteresis current controllers; source current shaping; outer voltage loop; proportional-integral controller; load voltage regulation; dSPACE signal processor; wide load variations; regulated output voltage; PWM BOOST RECTIFIERS; INPUT; VOLTAGE; DESIGN; SYSTEMS; AC;
D O I
10.1049/iet-pel.2012.0243
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, the analysis and design of a three-phase AC-DC converter followed by DC-DC Cuk converter modules to achieve unity power factor is presented. Two methods of reference current generation techniques are employed. In the first scheme, reference current is generated using instantaneous symmetrical component theory under balanced supply conditions. In the second scheme, extended synchronous detection methods such as equal current criterion, equal power criterion and equal impedance criterion are used for reference current generation under unbalanced supply conditions. The control strategy uses three hysteresis current controllers for source current shaping and an outer voltage loop with proportional-integral controller for load voltage regulation. To validate the proposed method, a prototype controlled by dSPACE signal processor is set up. Simulation and experimental results indicate that the proposed system offers regulated output voltage for wide load variations and provides power factor close to unity.
引用
收藏
页码:1892 / 1908
页数:17
相关论文
共 50 条
  • [31] Real-time emulation of a three-phase Vienna rectifier with DC voltage control and power factor correction
    Aiello, G.
    Cacciato, M.
    Scarcella, G.
    Scelba, G.
    Gennaro, F.
    Aiello, N.
    ELECTRICAL ENGINEERING, 2020, 102 (01) : 97 - 106
  • [32] Modeling and Simulation of a Novel Active Three-Phase Multilevel Power Factor Correction Front End - The "Negev" Rectifier
    Barbie, Eli
    Rabinovici, Raul
    Kuperman, Alon
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2020, 35 (01) : 462 - 473
  • [33] Real-time emulation of a three-phase Vienna rectifier with DC voltage control and power factor correction
    G. Aiello
    M. Cacciato
    G. Scarcella
    G. Scelba
    F. Gennaro
    N. Aiello
    Electrical Engineering, 2020, 102 : 97 - 106
  • [34] Computationally Efficient Optimal Switching Sequence Model Predictive Control for Three-Phase Vienna Rectifier Under Balanced and Unbalanced DC Links
    Xu, Bo
    Liu, Kaipei
    Ran, Xiaohong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (11) : 12268 - 12280
  • [35] Predictive Direct Power Control of Three-Phase Pulsewidth Modulation (PWM) Rectifier Using Space-Vector Modulation (SVM)
    Bouafia, Abdelouahab
    Gaubert, Jean-Paul
    Krim, Fateh
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (01) : 228 - 236
  • [36] RealTime Emulation of a Three-Phase Vienna Rectifier with Unity Power Factor Operations
    Aiello, G.
    Cacciato, M.
    Scarcella, G.
    Scelba, G.
    Gennaro, F.
    Aiello, N.
    12TH INTERNATIONAL CONFERENCE ELEKTRO 2018, 2018,
  • [37] Towards a 30 kW/liter, three-phase unity power factor rectifier
    Round, S. D.
    Karutz, P.
    Heldwein, M. L.
    Kolar, J. W.
    2007 POWER CONVERSION CONFERENCE - NAGOYA, VOLS 1-3, 2007, : 1218 - +
  • [38] Design and Implementation of Power Converters for Wind Generator with Three Phase Power Factor Correction
    Hua, Chih-Chiang
    Fang, Yi-Hsiung
    Chen, Wei-Tze
    Wang, Lyu-Jhih
    2013 IEEE 10TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS (IEEE PEDS 2013), 2013, : 1090 - 1095
  • [39] A Novel Voltage Judgment Component Injection Scheme for Balanced and Unbalanced DC-link Voltages in Three-Phase Vienna Rectifiers
    Liao, Yi-Hung
    Xie, Bing-Rong
    Liu, Jia-Sheng
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (11) : 13567 - 13577
  • [40] Robust cascade controller for the power factor of the three-phase supply and the induction motor velocity
    Morfin, Onofre A.
    Ruiz-Cruz, Riemann
    Valenzuela, Fredy A.
    Ramirez-Betancour, Reymundo
    Castaneda, Carlos E.
    Ornelas-Tellez, Fernando
    ISA TRANSACTIONS, 2023, 140 : 472 - 482