Oximetry: a new non-invasive method to detect metabolic effects induced by a local application of mechanical vibration

被引:0
作者
Felici, A. [1 ,2 ]
Trombetta, C. [1 ,2 ]
Abundo, P. [1 ]
Foti, C. [3 ]
Rosato, N. [4 ]
机构
[1] Tor Vergata Univ Hosp, Med Engn Serv, Viale Oxford 81, I-00133 Rome, Italy
[2] Tor Vergata Univ, Rehabil Med, Sch Adv Technol, I-00133 Rome, Italy
[3] Tor Vergata Univ, Dept Publ Hlth, Phys & Rehabil Med Chair, I-00133 Rome, Italy
[4] Tor Vergata Univ, Dept Expt Med, I-00133 Rome, Italy
来源
YOUNG RESEARCHER MEETING IN ROME 2012 | 2012年 / 383卷
关键词
SPECTROSCOPY;
D O I
10.1088/1742-6596/383/1/012017
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Mechanical vibrations application is increasingly common in clinical practice due to the effectiveness induced by these stimuli on the human body. Local vibration (LV) application allows to apply and act only where needed, focusing the treatment on the selected body segment. An experimental device for LV application was used to generate the vibrations. The aim of this study was to detect and analyze the metabolic effects induced by LV on the brachial bicep muscle by means of an oximeter. This device monitors tissue and muscle oxygenation using NIRS (Near Infrared Spectroscopy) and is able to determine the concentration of haemoglobin and oxygen saturation in the tissue. In a preliminary stage we also investigated the effects induced by LV application, by measuring blood pressure, heart rate, oxygen saturation and temperature. These data confirmed that the effects induced by LV application are actually localized. The results of the measurements obtained using the oximeter during the vibration application, have shown a variation of the concentrations. In particular an increase of oxygenate haemoglobin was shown, probably caused by an increased muscle activity and/or a rise in local temperature detected during the application.
引用
收藏
页数:6
相关论文
共 10 条
[1]  
Abundo P, 2011, J PHYS C SERIES, V280
[2]   Quantification in tissue near-infrared spectroscopy [J].
Delpy, DT ;
Cope, M .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 1997, 352 (1354) :649-659
[3]   FREQUENCY-DOMAIN MULTICHANNEL OPTICAL-DETECTOR FOR NONINVASIVE TISSUE SPECTROSCOPY AND OXIMETRY [J].
FANTINI, S ;
FRANCESCHINI, MA ;
MAIER, JS ;
WALKER, SA ;
BARBIERI, B ;
GRATTON, E .
OPTICAL ENGINEERING, 1995, 34 (01) :32-42
[4]   Principles, techniques, and limitations of near infrared spectroscopy [J].
Ferrari, M ;
Mottola, L ;
Quaresima, V .
CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 2004, 29 (04) :463-487
[5]  
Goodship AE, 2009, J ORTHOPAEDIC RES
[6]  
Ljoka C, 2006, EURA MEDICOPHYS, V42
[7]   In vivo absorption and scattering spectroscopy of biological tissues [J].
Taroni, P ;
Pifferi, A ;
Torricelli, A ;
Comelli, D ;
Cubeddu, R .
PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2003, 2 (02) :124-129
[8]  
Trombetta C, 2011, J PHYS C SERIES, V280
[9]  
Trombetta C, 2011, CONFERENCE PROCEEDIN, P593
[10]   Transcranial Doppler and near-infrared spectroscopy can evaluate the hemodynamic effect of carotid artery occlusion [J].
Vernieri, F ;
Tibuzzi, F ;
Pasqualetti, P ;
Rosato, N ;
Passarelli, F ;
Rossini, PM ;
Silvestrini, M .
STROKE, 2004, 35 (01) :64-70