Linear Energy Transfer-Guided Optimization in Intensity Modulated Proton Therapy: Feasibility Study and Clinical Potential

被引:138
作者
Giantsoudi, Drosoula
Grassberger, Clemens
Craft, David
Niemierko, Andrzej
Trofimov, Alexei
Paganetti, Harald
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2013年 / 87卷 / 01期
关键词
D O I
10.1016/j.ijrobp.2013.05.013
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the feasibility and potential clinical benefit of linear energy transfer (LET) guided plan optimization in intensity modulated proton therapy (IMPT). Methods and Materials: A multicriteria optimization (MCO) module was used to generate a series of Pareto-optimal IMPT base plans (BPs), corresponding to defined objectives, for 5 patients with head-and-neck cancer and 2 with pancreatic cancer. A Monte Carlo platform was used to calculate dose and LET distributions for each BP. A custom-designed MCO navigation module allowed the user to interpolate between BPs to produce deliverable Pareto-optimal solutions. Differences among the BPs were evaluated for each patient, based on dose-volume and LET-volume histograms and 3-dimensional distributions. An LET-based relative biological effectiveness (RBE) model was used to evaluate the potential clinical benefit when navigating the space of Pareto-optimal BPs. Results: The mean LET values for the target varied up to 30% among the BPs for the head-and-neck patients and up to 14% for the pancreatic cancer patients. Variations were more prominent in organs at risk (OARs), where mean LET values differed by a factor of up to 2 among the BPs for the same patient. An inverse relation between dose and LET distributions for the OARs was typically observed. Accounting for LET-dependent variable RBE values, a potential improvement on RBE-weighted dose of up to 40%, averaged over several structures under study, was noticed during MCO navigation. Conclusions: We present a novel strategy for optimizing proton therapy to maximize dose-averaged LET in tumor targets while simultaneously minimizing dose-averaged LET in normal tissue structures. MCO BPs show substantial LET variations, leading to potentially significant differences in RBE-weighted doses. Pareto-surface navigation, using both dose and LET distributions for guidance, provides the means for evaluating a large variety of deliverable plans and aids in identifying the clinically optimal solution. (C) 2013 Elsevier Inc.
引用
收藏
页码:216 / 222
页数:7
相关论文
共 9 条
[1]   Range uncertainty in proton therapy due to variable biological effectiveness [J].
Carabe, Alejandro ;
Moteabbed, Maryam ;
Depauw, Nicolas ;
Schuemann, Jan ;
Paganetti, Harald .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05) :1159-1172
[2]  
Craft D, 2012, INT J RADIAT ONCOL, V69, P1600
[3]   CERR: A computational environment for radiotherapy research [J].
Deasy, JO ;
Blanco, AI ;
Clark, VH .
MEDICAL PHYSICS, 2003, 30 (05) :979-985
[4]   VARIATIONS IN LINEAR ENERGY TRANSFER WITHIN CLINICAL PROTON THERAPY FIELDS AND THE POTENTIAL FOR BIOLOGICAL TREATMENT PLANNING [J].
Grassberger, Clemens ;
Trofimov, Alexei ;
Lomax, Anthony ;
Paganetti, Harald .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (05) :1559-1566
[5]   Physics settings for using the Geant4 toolkit in proton therapy [J].
Jarlskog, Christina Zacharatou ;
Paganetti, Harald .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) :1018-1025
[6]   Relative biological effectiveness (RBE) values for proton beam therapy [J].
Paganetti, H ;
Niemierko, A ;
Ancukiewicz, M ;
Gerweck, LE ;
Goitein, M ;
Loeffler, JS ;
Suit, HD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (02) :407-421
[7]   Dose to water versus dose to medium in proton beam therapy [J].
Paganetti, Harald .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (14) :4399-4421
[8]   TOPAS: An innovative proton Monte Carlo platform for research and clinical applications [J].
Perl, J. ;
Shin, J. ;
Schuemann, J. ;
Faddegon, B. ;
Paganetti, H. .
MEDICAL PHYSICS, 2012, 39 (11) :6818-6837
[9]   A model for the relative biological effectiveness of protons: The tissue specific parameter α/β of photons is a predictor for the sensitivity to LET changes [J].
Wedenberg, Minna ;
Lind, Bengt K. ;
Hardemark, Bjoern .
ACTA ONCOLOGICA, 2013, 52 (03) :580-588