Blood cell adhesion on sensor materials studied by light, scanning electron, and atomic-force microscopy

被引:3
作者
Hildebrand, G [1 ]
Kunze, S
Driver, M
机构
[1] Inst Bioproc & Analyt Measurement Tech EV, D-37308 Heilbad, Heiligenstadt, Germany
[2] Biocompatibles Ltd, Farnham GU9 8QL, Surrey, England
关键词
haemocompatibility; cell substrate interaction; bioreactor; flow through chamber; on-line adhesion kinetic; PC-polymer coatings;
D O I
10.1114/1.1424919
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Unwanted interactions of biomedical sensors with surrounding tissues, body fluids, and cells are one of the most crucial problems affecting their long-term stability. In vivo processes were simulated in a computer-controlled bioreactor connected to a flow chamber system. Optical sensor materials were inserted into a parallel-plate chamber and monitored by light microscopy in order to get information about the number of adhered cells. Tests with thrombocyte-enriched plasma show that novel phosphorylcholine (PC)-polymer-coated sensors appear to be more bioinert, and thus demonstrate better haemo-copatibility in comparison with untreated ass sensors. The influence of different materials on the morphology of adhered cells was investigated by off-line methods such as scanning electron microscopy (SEM) and atomic-force microscopy (AFM). SEM showed a reduction in the number of adhered thrombocytes and the lack of any fibrin network on the PC-polymer-modified glass surface, in contrast to the pure glass surface. AFM gives topographical information, and the calculated contact areas and cell volumes indicate smaller interactions between cells and sensor material in the case of PC-polymer-coated sensors. (C) 2001 Biomedical Engineering Society.
引用
收藏
页码:1100 / 1105
页数:6
相关论文
共 17 条
[1]   Classification of scanning probe microscopies - (Technical report) [J].
Friedbacher, G ;
Fuchs, H .
PURE AND APPLIED CHEMISTRY, 1999, 71 (07) :1337-1357
[2]   BIOMEMBRANE SURFACES AS MODELS FOR POLYMER DESIGN - THE POTENTIAL FOR HEMOCOMPATIBILITY [J].
HAYWARD, JA ;
CHAPMAN, D .
BIOMATERIALS, 1984, 5 (03) :135-142
[3]  
HILDEBRAND G, 2000, OPTO 2000 P WUNST GE, P199
[4]   PARALLEL FLOW ARTERIOVENOUS SHUNT FOR THE EXVIVO EVALUATION OF HEPARINIZED MATERIALS [J].
IP, WF ;
ZINGG, W ;
SEFTON, MV .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (02) :161-178
[5]   Inhibition of fibroblast cell adhesion on substrate by coating with 2-methacryloyloxyethyl phosphorylcholine polymers [J].
Ishihara, K ;
Ishikawa, E ;
Iwasaki, Y ;
Nakabayashi, N .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1999, 10 (10) :1047-1061
[6]  
ISHIHARA K, 1990, POLYM J, V22, P255
[7]   Platelet adhesion on the gradient surfaces grafted with phospholipid polymer [J].
Iwasaki, Y ;
Ishihara, K ;
Nakabayashi, N ;
Khang, G ;
Jeon, JH ;
Lee, JW ;
Lee, HB .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1998, 9 (08) :801-816
[8]   Surface characterization and in vitro blood compatibility of poly(ethylene terephthalate) immobilized with insulin and/or heparin using plasma glow discharge [J].
Kim, YJ ;
Kang, IK ;
Huh, MW ;
Yoon, SC .
BIOMATERIALS, 2000, 21 (02) :121-130
[9]  
LIEFEITH K, 2000, UNPUB P 10 HEIL KOLL
[10]  
LIEFEITH K, 1995, MATER CORROS, V46, P157