Field observations and failure analysis of the Basilica S. Maria di Collemaggio after the 2009 L'Aquila earthquake

被引:59
作者
Gattulli, Vincenzo [1 ]
Antonacci, Elena [1 ]
Vestroni, Fabrizio [2 ]
机构
[1] Univ Aquila, Dipartimento Ingn Civile, I-67040 Laquila, Italy
[2] Univ Roma La Sapienza, Dipartimento Ingn Strutturale & Geotecn, I-00185 Rome, Italy
关键词
Monumental structures; Masonry; Seismic analysis; Dynamic testing; Nonlinear analyses; CHURCH; BEHAVIOR; MODELS;
D O I
10.1016/j.engfailanal.2013.01.020
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
On Monday, the 6th of April, 2009, a devastating earthquake struck L'Aquila causing the partial collapse of the Basilica S. Maria di Collemaggio, an important symbol of the city. The mechanism of the transept structure's failure, which left the external boundary walls almost undamaged, probably due to the sudden collapse of the large multi-lobed pillars at the end of the nave, is discussed in the paper by different points of view. A brief historical review of the monument restorations is followed by the analysis of the damage scenario recorded during the post-earthquake inspections. Finite element models of the Basilica, updated on the basis of available dynamic tests, have been used to perform a seismic assessment by response spectrum analysis according to the current Italian code, showing a high vulnerability, in the transversal direction larger than in the longitudinal one. The AQK earthquake accelerograms, recorded close to the site, have evidenced a prevailing component almost aligned with the longitudinal Basilica axis; the intensity is comparable with the one provided by the code, with exception in the vertical one greater than expected. Static nonlinear analyses have furnished the crack propagation in the masonry walls due to the increase of longitudinal horizontal loads. The presented failure description obtained by structural modeling is coherent with the direction of the registered polarized seismic action and it is compatible with the observed damage and with most of the debris positions coming from the collapse of the transept structures. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:715 / 734
页数:20
相关论文
共 26 条
[1]  
[Anonymous], 2012, MIDAS FEA VERS 1 1 R
[2]  
[Anonymous], 2012, MIDAS GEN VERS 3 1
[3]  
Antonacci E., 2004, P STRUCT AN HIST CON
[4]  
Antonacci E., 2001, P 2 INT C STUD ANC S
[5]  
Antonacci E, 2001, MODELLING SIMULATION, V30, P1
[6]  
BARTOLOMUCCI C., 2004, SANTA MARIA COLLEMAG
[7]   Assessment of seismic resistance of a basilica-type church under earthquake loading: Modelling and analysis [J].
Betti, Michele ;
Vignoli, Andrea .
ADVANCES IN ENGINEERING SOFTWARE, 2008, 39 (04) :258-283
[8]   Numerical assessment of the static and seismic behaviour of the basilica of Santa Maria all'Impruneta (Italy) [J].
Betti, Michele ;
Vignoli, Andrea .
CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (12) :4308-4324
[9]  
BRANDI Cesare., 1963, Teoria del restauro"
[10]  
Brusaporci S., 2006, DISEGNO CONOSCENZA, P75