Advantages of the Biomimetic Nanostructured Films as an Immobilization Method vs. the Carbon Paste Classical Method

被引:13
作者
Apetrei, Constantin [1 ]
Antonio de Saja, Jose [2 ]
Zurro, Javier [3 ]
Luz Rodriguez-Mendez, Maria [4 ]
机构
[1] Dunarea de Jos Univ Galati, Dept Chem Phys & Environm, Fac Sci & Environm, Galati 800008, Romania
[2] Univ Valladolid, Fac Sci, Dept Condensed Matter Phys, E-47011 Valladolid, Spain
[3] Univ Valladolid, Infirm Sch Palencia, Palencia 34004, Spain
[4] Univ Valladolid, Sch Ind Engn, Dept Phys Chem & Inorgan Chem, E-47011 Valladolid, Spain
关键词
bisphthalocyanine; Langmuir-Blodgett; carbon paste; biosensor; tyrosinase; PHENOLIC-COMPOUNDS; LUTETIUM BISPHTHALOCYANINE; ANTIOXIDANT CAPACITY; ALTERNATIVE METHOD; POLYPHENOL CONTENT; RED WINE; SOL-GEL; TYROSINASE; ELECTRODES;
D O I
10.3390/catal2040517
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Tyrosinase-based biosensors containing a phthalocyanine as electron mediator have been prepared by two different methods. In the first approach, the enzyme and the electron mediator have been immobilized in carbon paste electrodes. In the second method, they have been introduced in an arachidic acid Langmuir-Blodgett nanostructured film that provides a biomimetic environment. The sensing properties of non-nanostructured and nanostructured biosensors towards catechol, catechin and phenol have been analyzed and compared. The enzyme retains the biocatalytic properties in both matrixes. However, the nanostructured biomimetic films show higher values of maximum reaction rates and lowest apparent Michaelis-Menten constants. In both types of sensors, the sensitivity follows the decreasing order catechol > catechin > phenol. The detection limits observed are in the range of 1.8-5.4 mu M for Langmuir-Blodgett biosensors and 8.19-8.57 mu M for carbon paste biosensors. In summary, it has been demonstrated that the Langmuir-Blodgett films provide a biomimetic environment and nanostructured biosensors show better performances in terms of kinetic, detection limit and stability.
引用
收藏
页码:517 / 531
页数:15
相关论文
共 45 条
[1]  
Albery WJ., 1987, BIOSENSORS FUNDAMENT, P180
[2]   Total polyphenol content and antioxidant capacity of commercially available tea (Camellia sinensis) in Argentina [J].
Anesini, Claudia ;
Ferraro, Graciela E. ;
Filip, Rosana .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (19) :9225-9229
[3]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[4]   Spectroelectrochemical characterisation of Langmuir-Schaefer films of heteroleptic phthalocyanine complexes.: Potential applications [J].
Apetrei, C. ;
Casilli, S. ;
De Luca, M. ;
Valli, L. ;
Jiang, J. ;
Rodriguez-Mendez, M. L. ;
De Saja, J. A. .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2006, 284 :574-582
[5]   Amperometric tyrosinase based biosensor using an electropolymerized phosphate-doped polypyrrole film as an immobilization support. Application for detection of phenolic compounds [J].
Apetrei, C. ;
Rodriguez-Mendez, M. L. ;
De Saja, J. A. .
ELECTROCHIMICA ACTA, 2011, 56 (24) :8919-8925
[6]   Biomimetic biosensor based on lipidic layers containing tyrosinase and lutetium bisphthalocyanine for the detection of antioxidants [J].
Apetrei, C. ;
Alessio, P. ;
Constantino, C. J. L. ;
de Saja, J. A. ;
Rodriguez-Mendez, M. L. ;
Pavinatto, F. J. ;
Ramos Fernandes, E. Giuliani ;
Zucolotto, V. ;
Oliveira, O. N., Jr. .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (05) :2513-2519
[7]   Monitoring of evolution during red wine aging in oak barrels and alternative method by means of an electronic panel test [J].
Apetrei, I. M. ;
Rodriguez-Mendez, M. L. ;
Apetrei, C. ;
Nevares, I. ;
del Alamo, M. ;
de Saja, J. A. .
FOOD RESEARCH INTERNATIONAL, 2012, 45 (01) :244-249
[8]   Sensitive gas chromatographic-mass spectrometric method for the determination of phthalate esters, alkylphenols, bisphenol A and their chlorinated derivatives in wastewater samples [J].
Ballesteros, Oscar ;
Zafra, Alberto ;
Navalon, Alberto ;
Vilchez, Jose Luis .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1121 (02) :154-162
[9]  
Baruah J.B, 2011, CHEM PHENOLIC COMPUN
[10]   Langmuir-Blodgett film based biosensor for estimation of phenol derivatives [J].
Cabaj, Joanna ;
Soloducho, Jadwiga ;
Nowakowska-Oleksy, Anna .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 143 (02) :508-515