MPPC Array in the Readout of CsI:Tl, LSO:Ce:Ca, LaBr3:Ce, and BGO Scintillators

被引:31
作者
Grodzicka, M. [1 ]
Moszynski, M. [1 ]
Szczesniak, T. [1 ]
Szawlowski, M. [1 ]
Wolski, D. [1 ]
Baszak, J.
机构
[1] Natl Ctr Nucl Res, PL-05400 Otwock, Poland
关键词
Energy resolution; MPPC; photodetectors; scintillation detectors; SiPMs; ENERGY RESOLUTION; PHOTOMULTIPLIERS;
D O I
10.1109/TNS.2012.2215343
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The aim of this work is to provide the characteristics of MPPC arrays with an active area of 6 x 6 mm(2) in gamma-ray spectrometry with CsI:Tl, LSO:Ce:Ca, LaBr3:Ce and BGO scintillators. The chosen scintillators have significantly different decay times of the scintillation pulses and different wavelengths of emission peaks. This allowed an investigation into the dependence of MPPC readout features on the MPPC and scintillator characteristics. The study of influence of effective dead time and the number of MPPC pixels on a readout response in relation to the brightness and speed of the scintillator were performed. The measurements covered a selection of MPPC optimum operating voltage, verification of the linearity range for a given decay time of the crystals, verification of the excess noise factor for the optimal voltage and evaluation of the Photon Detection Efficiency (PDE). The results of energy resolution and non-proportionality obtained with the MPPC array readout of CsI: Tl and BGO were compared to those obtained for the same crystals with the XP2020Q PMT readout. The results show that an MPPC can be used as effectively as a PMT for gamma spectrometry measurements in the whole tested energy ranges (up to 1.3 MeV) and for many types of scintillation crystals (BGO, CsI:Tl).
引用
收藏
页码:3294 / 3303
页数:10
相关论文
共 15 条
[1]   YSO, LSO, GSO and LGSO. A study of energy resolution and nonproportionality. [J].
Balcerzyk, M ;
Moszynski, M ;
Kapusta, M ;
Wolski, D ;
Pawelke, J ;
Melcher, CL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1319-1323
[2]  
Bertolaccini M., 1968, Nucl. Electr. Symp., V1, P1
[3]   Characterisation studies of silicon photomultipliers [J].
Eckert, Patrick ;
Schultz-Coulon, Hans-Christian ;
Shen, Wei ;
Stamen, Rainer ;
Tadday, Alexander .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 620 (2-3) :217-226
[4]  
Grodzicka M., 2010, IEEE NUCL SCI S C KN
[5]  
Grodzicka M., 2011, IEEE NUCL SCI S C VA
[6]   TUKAN - An 8K pulse height analyzer and multi-channel scaler with a PCI or a USB interface [J].
Guzik, Z ;
Borsuk, S ;
Traczyk, K ;
Plominski, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :231-235
[7]   Study of LaBr3 crystals coupled to photomultipliers and avalanche photodiodes [J].
Moszynski, M. ;
Swiderski, L. ;
Szczesniak, T. ;
Nassalski, A. ;
Syntfeld-Kazuch, A. ;
Czarnacki, W. ;
Pausch, G. ;
Stein, J. ;
Lavoute, P. ;
Lherbert, F. ;
Kniest, F. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) :1774-1780
[8]  
Moszynski M., 2005, Proceedings of the SPIE - The International Society for Optical Engineering, V5922, P592205, DOI 10.1117/12.622316
[9]   Intrinsic energy resolution and light yield nonproportionality of BGO [J].
Moszynski, M ;
Balcerzyk, M ;
Czarnacki, W ;
Kapusta, M ;
Klamra, W ;
Syntfeld, A ;
Szawlowski, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) :1074-1079
[10]   Absolute light output of scintillators [J].
Moszynski, M ;
Kapusta, M ;
Mayhugh, M ;
Wolski, D ;
Flyckt, SO .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1052-1061