Risks and benefits of invasive epilepsy surgery workup with implanted subdural and depth electrodes

被引:121
作者
Wellmer, Joerg [1 ]
von der Groeben, Ferdinand [2 ]
Klarmann, Ute [3 ]
Weber, Christian [2 ]
Elger, Christian E. [2 ]
Urbach, Horst [4 ]
Clusmann, Hans [5 ,6 ]
von Lehe, Marec [5 ]
机构
[1] Univ Hosp Knappschaftskrankenhaus, Dept Neurol, D-44892 Bochum, Germany
[2] Univ Hosp Bonn, Dept Epileptol, Bonn, Germany
[3] Univ Hosp Bonn, Inst Med Biometry Informat & Epidemiol, Bonn, Germany
[4] Univ Hosp Bonn, Dept Neuroradiol, Bonn, Germany
[5] Univ Hosp Bonn, Dept Neurosurg, Bonn, Germany
[6] RWTH Aachen Univ Hosp, Dept Neurosurg, Aachen, Germany
关键词
Epilepsy surgery; Invasive workup; Complications; Seizure outcome; FOCAL CORTICAL DYSPLASIA; RESISTANT PARTIAL EPILEPSY; PRESURGICAL EVALUATION; CLINICAL ARTICLE; ELECTRICAL-STIMULATION; GRID ELECTRODES; COMPLICATIONS; EXPERIENCE; RESECTION; OUTCOMES;
D O I
10.1111/j.1528-1167.2012.03545.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose: In patients with pharmacoresistant focal-onset seizures, invasive presurgical workup can identify epilepsy surgery options when noninvasive workup has failed. Yet, the potential benefit must be balanced with procedure-related risks. This study examines risks associated with the implantation of subdural strip and grid, and intracerebral depth electrodes. Benefit of invasive monitoring is measured by seizure outcomes. Diagnostic procedures made possible by electrode implantation are described. Methods: Retrospective evaluation of invasive workups in 242 epilepsy surgery candidates and additional 18 patients with primary brain tumors implanted for mapping only. Complications are scaled in five grades of severity. A regression analysis identifies risk factors for complications. Outcome is classified according to Engel's classification. Key Findings: Complications of any type were documented in 23% of patients, and complications requiring surgical revision in 9%. We did not find permanent morbidity or mortality. Major risk factor for complications was the implantation of grids and the implantation of electrode assemblies comprising strip and grid electrodes. Depth electrodes were significantly correlated with a lower risk. Tumors were not correlated with higher complication rates. Chronic invasive monitoring of 3-40 days allowed seizure detection in 99.2% of patients with epilepsy and additional extensive mapping procedures. Patients with epilepsy with follow-up >24 months (n = 165) had an Engel class 1a outcome in 49.7% if epilepsy surgery was performed, but only 6.3% when surgery was rejected. Significance: The benefit of chronic invasive workup outweighs its risks, but complexity of implantations should be kept to a minimum.
引用
收藏
页码:1322 / 1332
页数:11
相关论文
共 33 条
[1]   SUBDURAL AND DEPTH ELECTRODES IN THE PRESURGICAL EVALUATION OF EPILEPSY [J].
BEHRENS, E ;
ZENTNER, J ;
VANROOST, D ;
HUFNAGEL, A ;
ELGER, CE ;
SCHRAMM, J .
ACTA NEUROCHIRURGICA, 1994, 128 (1-4) :84-87
[2]   Surgical and neurological complications in a series of 708 epilepsy surgery procedures [J].
Behrens, E ;
Schramm, J ;
Zentner, J ;
Konig, R .
NEUROSURGERY, 1997, 41 (01) :1-9
[3]   Morbidity associated with the use of intracranial electrodes for epilepsy surgery [J].
Burneo, JG ;
Steven, DA ;
McLachlan, RS ;
Parrent, AG .
CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2006, 33 (02) :223-227
[4]   Remission and relapse in a drug-resistant epilepsy population followed prospectively [J].
Callaghan, Brian ;
Schlesinger, Malka ;
Rodemer, William ;
Pollard, John ;
Hesdorffer, Dale ;
Hauser, W. Allen ;
French, Jacqueline .
EPILEPSIA, 2011, 52 (03) :619-626
[5]   Likelihood of seizure remission in an adult population with refractory epilepsy [J].
Callaghan, Brian C. ;
Anand, Kishlay ;
Hesdorffer, Dale ;
Hauser, W. Allen ;
French, Jacqueline A. .
ANNALS OF NEUROLOGY, 2007, 62 (04) :382-389
[6]   Seizure control outcomes after resection of dysembryoplastic neuroepithelial tumor in 50 patients Clinical article [J].
Chang, Edward F. ;
Christie, Catherine ;
Sullivan, Joseph E. ;
Garcia, Paul A. ;
Thian, Tarik ;
Gupta, Nalin ;
Berger, Mitchel S. ;
Barbaro, Nicholas M. .
JOURNAL OF NEUROSURGERY-PEDIATRICS, 2010, 5 (01) :123-130
[7]   Stereoelectroencephalography in the presurgical evaluation of focal epilepsy: A retrospective analysis of 215 procedures [J].
Cossu, M ;
Cardinale, F ;
Castana, L ;
Citterio, A ;
Francione, S ;
Tassi, L ;
Benabid, AL ;
Lo Russo, G .
NEUROSURGERY, 2005, 57 (04) :706-718
[8]  
Engel Jerome Jr., 1993, P609
[9]   Safety of intrahippocampal depth electrodes for presurgical evaluation of patients with intractable epilepsy [J].
Fernandez, G ;
Hufnagel, A ;
VanRoost, D ;
Helmstaedter, C ;
Wolf, HK ;
Zentner, J ;
Schramm, J ;
Elger, CE .
EPILEPSIA, 1997, 38 (08) :922-929
[10]   Subdural electrode-associated complications: A 20-year experience [J].
Fountas, Kostas N. ;
Smith, Joseph R. .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2007, 85 (06) :264-272