Optical Fibre Pressure Sensors in Medical Applications

被引:161
作者
Poeggel, Sven [1 ]
Tosi, Daniele [2 ]
Duraibabu, DineshBabu [1 ]
Leen, Gabriel [1 ]
McGrath, Deirdre [3 ]
Lewis, Elfed [1 ]
机构
[1] Univ Limerick, Opt Fibre Sensors Res Ctr, Limerick, Ireland
[2] Nazarbayev Univ, Sch Engn, Astana 010000, Kazakhstan
[3] Univ Limerick, Grad Entry Med Sch, Limerick, Ireland
基金
爱尔兰科学基金会;
关键词
optical fibre sensors; Fabry; Perot interferometer; pressure sensors; URINARY-TRACT FUNCTION; INTRAAORTIC-BALLOON; INTRAARTICULAR PRESSURE; MANOMETRY CATHETER; CLINICAL-PRACTICE; RECENT PROGRESS; SYSTEM; TRANSDUCER; FORCE; ABLATION;
D O I
10.3390/s150717115
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article is focused on reviewing the current state-of-the-art of optical fibre pressure sensors for medical applications. Optical fibres have inherent advantages due to their small size, immunity to electromagnetic interferences and their suitability for remote monitoring and multiplexing. The small dimensions of optical fibre-based pressure sensors, together with being lightweight and flexible, mean that they are minimally invasive for many medical applications and, thus, particularly suited to in vivo measurement. This means that the sensor can be placed directly inside a patient, e.g., for urodynamic and cardiovascular assessment. This paper presents an overview of the recent developments in optical fibre-based pressure measurements with particular reference to these application areas.
引用
收藏
页码:17115 / 17148
页数:34
相关论文
共 201 条
[31]   Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure [J].
Chobanian, AV ;
Bakris, GL ;
Black, HR ;
Cushman, WC ;
Green, LA ;
Izzo, JL ;
Jones, DW ;
Materson, BJ ;
Oparil, S ;
Wright, JT ;
Roccella, EJ .
HYPERTENSION, 2003, 42 (06) :1206-1252
[32]   Development of Clinically Relevant Implantable Pressure Sensors: Perspectives and Challenges [J].
Clausen, Ingelin ;
Glott, Thomas .
SENSORS, 2014, 14 (09) :17686-17702
[33]  
Components J.M.M, 2015, TECHNICAL REPORT
[34]   Comparison of Air-Charged and Water-Filled Urodynamic Pressure Measurement Catheters [J].
Cooper, M. A. ;
Fletter, P. C. ;
Zaszczurynski, P. J. ;
Damaser, M. S. .
NEUROUROLOGY AND URODYNAMICS, 2011, 30 (03) :329-334
[35]   Accuracy and Reproducibility of High-definition Anorectal Manometry and Pressure Topography Analyses in Healthy Subjects [J].
Coss-Adame, Enrique ;
Rao, Satish S. C. ;
Valestin, Jessica ;
Ali-Azamar, Amyra ;
Remes-Troche, Jose M. .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2015, 13 (06) :1143-+
[36]   Miniature optical fiber pressure microsensors for in vivo measurement of intramuscular pressure [J].
Cottler, P. S. ;
Blevins, D. ;
Averett, J. ;
Wavering, T. A. ;
Morrow, D. A. ;
Shin, A. Y. ;
Kaufman, K. R. .
OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS VII, 2007, 6433
[37]   Performance Characteristics of a New Generation Pressure Microsensor for Physiologic Applications [J].
Cottler, Patrick S. ;
Karpen, Whitney R. ;
Morrow, Duane A. ;
Kaufman, Kenton R. .
ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (08) :1638-1645
[38]   A NEW TRANSDUCER-TIPPED FIBER OPTIC CATHETER FOR MEASURING INTRAMUSCULAR PRESSURES [J].
CRENSHAW, AG ;
STYF, JR ;
MUBARAK, SJ ;
HARGENS, AR .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (03) :464-468
[39]   INTRAMUSCULAR PRESSURES DURING EXERCISE - AN EVALUATION OF A FIBER OPTIC TRANSDUCER-TIPPED CATHETER SYSTEM [J].
CRENSHAW, AG ;
STYF, JR ;
HARGENS, AR .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1992, 65 (02) :178-182
[40]  
Date P., 2015, APPROVED AM NATL STA