Dosimetric comparison of three different treatment modalities for total scalp irradiation: the conventional lateral photon-electron technique, helical tomotherapy, and volumetric-modulated arc therapy

被引:21
作者
Song, Jin Ho [1 ]
Jung, Ji-Young [2 ]
Park, Hyung-Wook [3 ]
Lee, Gi Woong [4 ]
Chae, Soo-Min [4 ]
Kay, Chul Seung [2 ]
Son, Seok Hyun [2 ]
机构
[1] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Radiat Oncol, Seoul, South Korea
[2] Catholic Univ Korea, Coll Med, Incheon St Marys Hosp, Dept Radiat Oncol, Seoul, South Korea
[3] Catholic Univ Korea, Coll Med, Yeouido St Marys Hosp, Dept Radiat Oncol, Seoul, South Korea
[4] Cheju Halla Gen Hosp, Dept Radiat Oncol, Jeju, South Korea
关键词
total scalp irradiation; lateral photon-electron technique; helical tomotherapy; volumetric-modulated arc therapy; hippocampus; RADIOTHERAPY; CANCER; IMRT; BRACHYTHERAPY; RAPIDARC; SURFACE; BREAST; HEAD; SKIN;
D O I
10.1093/jrr/rru049
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to compare lateral photon-electron (LPE), helical tomotherapy (HT), and volumetric-modulated arc therapy (VMAT) plans for total scalp irradiation. We selected a single adult model case and compared the dosimetric results for the three plans. All plans mainly used 6-MV photon beams, and the prescription dose was 60 Gy in 30 fractions. First, we compared the LPE, HT and VMAT plans, with all plans including a 1-cm bolus. We also compared HT plans with and without the bolus. The conformity indices for LPE, HT and VMAT were 1.73, 1.35 and 1.49, respectively. The HT plan showed the best conformity and the LPE plan showed the worst. However, the plans had similar homogeneity indexes. The dose to the hippocampus was the highest in the VMAT plan, with a mean of 6.7 Gy, compared with 3.5 Gy in the LPE plan and 4.8 Gy in the HT plan. The doses to the optical structures were all within the clinically acceptable range. The beam-on time and monitor units were highest in the HT plan. The HT plans with and without a bolus showed similar target coverage and organ-at-risk (OAR) sparing. The HT plan showed the best target coverage and conformity, with low doses to the brain and hippocampus. This plan also had the advantage of not necessarily requiring a bolus. Although the VMAT plan showed better conformity than the LPE plan and acceptable OAR sparing, the dose to the hippocampus should be considered when high doses are prescribed.
引用
收藏
页码:717 / 726
页数:10
相关论文
共 32 条
[1]   EVALUATION OF A TOTAL SCALP ELECTRON-IRRADIATION TECHNIQUE [J].
ABLE, CM ;
MILLS, MD ;
MCNEESE, MD ;
HOGSTROM, KR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (04) :1063-1072
[2]  
Akazawa C, 1989, Med Dosim, V14, P129
[3]   Dose to the skin in helical tomotherapy: Results of in vivo measurements with radiochromic films [J].
Avanzo, Michele ;
Drigo, Annalisa ;
Kaiser, Stefano Ren ;
Roggio, Antonella ;
Sartor, Giovanna ;
Chiovati, Paola ;
Franchin, Giovanni ;
Mascarin, Maurizio ;
Capra, Elvira .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (03) :304-311
[4]   A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy [J].
Baltas, D ;
Kolotas, C ;
Geramani, K ;
Mould, RF ;
Ioannidis, G ;
Kekchidi, M ;
Zamboglou, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (02) :515-524
[5]   Treatment of extensive scalp lesions with segmental intensity-modulated photon therapy [J].
Bedford, JL ;
Childs, PJ ;
Hansen, VN ;
Warrington, AP ;
Mendes, RL ;
Glees, JP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (05) :1549-1558
[6]   A dosimetric comparison of electronic compensation, conventional intensity modulated radiotherapy, and tomotherapy in patients with early-stage carcinoma of the left breast [J].
Caudell, Jimmy J. ;
De los Santos, Jennifer F. ;
Keene, Kimberly S. ;
Fiveash, John B. ;
Wang, Wenquan ;
Carlisle, Janice D. ;
Popple, Richard .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (05) :1505-1511
[7]   Hippocampal Dosimetry Predicts Neurocognitive Function Impairment After Fractionated Stereotactic Radiotherapy for Benign or Low-Grade Adult Brain Tumors [J].
Gondi, Vinai ;
Hermann, Bruce P. ;
Mehta, Minesh P. ;
Tome, Wolfgang A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02) :348-354
[8]   Why avoid the hippocampus? A comprehensive review [J].
Gondi, Vinai ;
Tome, Wolfgang A. ;
Mehta, Minesh P. .
RADIOTHERAPY AND ONCOLOGY, 2010, 97 (03) :370-376
[9]   HIPPOCAMPAL-SPARING WHOLE-BRAIN RADIOTHERAPY: A "HOW-TO" TECHNIQUE USING HELICAL TOMOTHERAPY AND LINEAR ACCELERATOR-BASED INTENSITY-MODULATED RADIOTHERAPY [J].
Gondi, Vinai ;
Tolakanahalli, Ranjini ;
Mehta, Minesh P. ;
Tewatia, Dinesh ;
Rowley, Howard ;
Kuo, John S. ;
Khuntia, Deepak ;
Tome, Wolfgang A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (04) :1244-1252
[10]   OUTCOMES AFTER DEFINITIVE TREATMENT FOR CUTANEOUS ANGIOSARCOMA OF THE FACE AND SCALP [J].
Guadagnolo, B. Ashleigh ;
Zagars, Gunar K. ;
Araujo, Dejka ;
Ravi, Vinod ;
Shellenberger, Thomas D. ;
Sturgis, Erich M. .
HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2011, 33 (05) :661-667