Six decades of lateral flow immunoassay: from determining metabolic markers to diagnosing COVID-19

被引:122
作者
Andryukov, Boris G. [1 ,2 ]
机构
[1] Somov Res Inst Epidemiol & Microbiol, Vladivostok, Russia
[2] Far Eastern Fed Univ FEFU, Vladivostok, Russia
关键词
lateral flow immunoassays (LFIA); clinical laboratory diagnostics; 'point-of-care testing' concept; RAPID DETECTION; ASSAY; SMARTPHONE; PLATFORM; ANTIBODY; PATIENT; DENGUE; VIRUS; FEVER; STRIP;
D O I
10.3934/microbiol.2020018
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Technologies based on lateral flow immunoassay (LFIA), known in some countries of the world as immunochromatographic tests, have been successfully used for the last six decades in diagnostics of many diseases and conditions as they allow rapid detection of molecular ligands in biosubstrates. The popularity of these diagnostic platforms is constantly increasing in healthcare facilities, particularly those facing limited budgets and time, as well as in household use for individual health monitoring. The advantages of these low-cost devices over modern laboratory-based analyzers come from their availability, opportunity of rapid detection, and ease of use. The attractiveness of these portable diagnostic tools is associated primarily with their high analytical sensitivity and specificity, as well as with the easy visual readout of results. These qualities explain the growing popularity of LFIA in developing countries, when applied at small hospitals, in emergency situations where screening and monitoring health condition is crucially important, and as well as for self-testing of patients. These tools have passed the test of time, and now LFIA test systems are fully consistent with the world's modern concept of 'point-of-care testing', finding a wide range of applications not only in human medicine, but also in ecology, veterinary medicine, and agriculture. The extensive opportunities provided by LFIA contribute to the continuous development and improvement of this technology and to the creation of new-generation formats. This review will highlight the modern principles of design of the most widely used formats of test-systems for clinical laboratory diagnostics, summarize the main advantages and disadvantages of the method, as well as the current achievements and prospects of the LFIA technology. The latest innovations are aimed at improving the analytical performance of LFIA platforms for the diagnosis of bacterial and viral infections, including COVID-19.
引用
收藏
页码:280 / 304
页数:25
相关论文
共 119 条
[1]   Validity of a single antibody-based lateral flow immunoassay depending on graphene oxide for highly sensitive determination of E. coli O157:H7 in minced beef and river water [J].
Abdelazeem Hassan, Abdelrahim Hussein ;
Francisco Bergua, Jose ;
Morales-Narvaez, Eden ;
Mekoci, Arben .
FOOD CHEMISTRY, 2019, 297
[2]   The Detection and Genetic Characterization Based on the S1 Gene Region of BCoVs from Respiratory and Enteric Infections in Turkey [J].
Alkan, F. ;
Ozkul, A. ;
Bilge-Dagalp, S. ;
Karaoglu, T. ;
Oguzoglu, T. C. ;
Caliskan, E. ;
Burgu, I. .
TRANSBOUNDARY AND EMERGING DISEASES, 2011, 58 (02) :179-185
[3]   Multiplex Lateral Flow Immunoassay: An Overview of Strategies towards High-throughput Point-of-Need Testing [J].
Anfossi, Laura ;
Di Nardo, Fabio ;
Cavalera, Simone ;
Giovannoli, Cristina ;
Baggiani, Claudio .
BIOSENSORS-BASEL, 2018, 9 (01)
[4]   Hand-Held Reader for Colorimetric Sensor Arrays [J].
Askim, Jon R. ;
Suslick, Kenneth S. .
ANALYTICAL CHEMISTRY, 2015, 87 (15) :7810-7816
[5]  
Aytu Biosciences/ Orient Gene Biotech official website, 2020, COVID 19 IGG IGM POI
[6]  
Banerjee R, 2018, ANALYST, V143, P1970, DOI [10.1039/c8an00307f, 10.1039/C8AN00307F]
[7]   Pregnancy testing with hCG - future prospects [J].
Berger, Peter ;
Sturgeon, Catharine .
TRENDS IN ENDOCRINOLOGY AND METABOLISM, 2014, 25 (12) :637-648
[8]   Real-Time Sequence-Validated Loop-Mediated Isothermal Amplification Assays for Detection of Middle East Respiratory Syndrome Coronavirus (MERS-CoV) [J].
Bhadra, Sanchita ;
Jiang, Yu Sherry ;
Kumar, Mia R. ;
Johnson, Reed F. ;
Hensley, Lisa E. ;
Ellington, Andrew D. .
PLOS ONE, 2015, 10 (04)
[9]  
Biohit Healthcare (Heifei) Co. Ltd. official website, 2020, BIOH SARS COV 2 IGM
[10]   Development of Prototype Filovirus Recombinant Antigen Immunoassays [J].
Boisen, Matt L. ;
Oottamasathien, Darin ;
Jones, Abigail B. ;
Millett, Molly M. ;
Nelson, Diana S. ;
Bornholdt, Zachary A. ;
Fusco, Marnie L. ;
Abelson, Dafna M. ;
Oda, Shun-ichiro ;
Hartnett, Jessica N. ;
Rowland, Megan M. ;
Heinrich, Megan L. ;
Akdag, Marjan ;
Goba, Augustine ;
Momoh, Mambu ;
Fullah, Mohammed ;
Baimba, Francis ;
Gbakie, Michael ;
Safa, Sadiki ;
Fonnie, Richard ;
Kanneh, Lansana ;
Cross, Robert W. ;
Geisbert, Joan B. ;
Geisbert, Thomas W. ;
Kulakosky, Peter C. ;
Grant, Donald S. ;
Shaffer, Jeffery G. ;
Schieffelin, John S. ;
Wilson, Russell B. ;
Saphire, Erica Ollmann ;
Branco, Luis M. ;
Garry, Robert F. ;
Khan, S. Humarr ;
Pitts, Kelly R. .
JOURNAL OF INFECTIOUS DISEASES, 2015, 212 :S359-S367