Identifying poor compliance with CPAP in obstructive sleep apnoea: A simple prediction equation using data after a two week trial

被引:22
作者
Ghosh, Dipansu [1 ]
Allgar, Victoria [2 ]
Elliott, Mark W. [1 ]
机构
[1] St James Univ Hosp, Dept Resp Med, Leeds LS9 7TF, W Yorkshire, England
[2] Univ York, Dept Med Stat, Hull York Med Sch Hlth Sci, York YO10 5DD, N Yorkshire, England
关键词
Sleep apnoea; CPAP; Compliance; POSITIVE AIRWAY PRESSURE; LONG-TERM COMPLIANCE; BLOOD-PRESSURE; ASSOCIATION; THERAPY; ADHERENCE; DETERMINANTS; INDEX;
D O I
10.1016/j.rmed.2012.10.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: It is important to identify those patients with OSA who are likely to benefit from long term CPAP, not only for symptomatic relief, but also potentially to reduce vascular morbidity and mortality, but are unlikely to adhere to treatment. We have validated a model which we developed previously for predicting long term compliance with CPAP using data after a 2 week trial. Methods: The model was applied retrospectively to patients undergoing a trial of CPAP. Predicted outcomes were compared with the actual outcomes. Results: Prediction equation was applied to 448 patients [77% males, Age 53 +/- 11 years, ESS 14 +/- 4, AHI 37 +/- 24]. Of 407 patients included in the study 333 were issued a CPAP and 74 declined long term CPAP. At one year, 81% patients were using CPAP at least 2 h and 70% >4 h. A score >50% from the equation was associated with a high probability of CPAP usage at one year. 295 patients had a probability score of >50% and of them 84% were using CPAP satisfactorily at 1 year. The sensitivity in identifying compliers was 91%. Of the 112 patients with a score <= 50%, 38 opted to accept CPAP and 60% of them were still using it at 1 year. Conclusions: This simple equation has now been validated to be highly sensitive in identifying long term compliers and it also identifies those with worse compliance. This group could be targeted for a more intensive follow up regime with the aim of improving their compliance. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:936 / 942
页数:7
相关论文
共 46 条
[1]   Determinants of continuous positive airway pressure compliance in a group of Greek patients with obstructive sleep apnea [J].
Amfilochiou, Anastasia ;
Tsara, Venetia ;
Kolilekas, Likurgos ;
Gizopoulou, Evangelia ;
Maniou, Chrysoula ;
Bouros, Demosthenes ;
Polychronopoulos, Vlasios .
EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2009, 20 (06) :645-650
[2]   Association of sleep-disordered breathing and the occurrence of stroke [J].
Arzt, M ;
Young, T ;
Finn, L ;
Skatrud, JB ;
Bradley, TD .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2005, 172 (11) :1447-1451
[3]   Type 2 diabetes, glycemic control, and continuous positive airway pressure in obstructive sleep apnea [J].
Babu, AR ;
Herdegen, J ;
Fogelfeld, L ;
Shott, S ;
Mazzone, T .
ARCHIVES OF INTERNAL MEDICINE, 2005, 165 (04) :447-452
[4]   Determinants of compliance with nasal continuous positive airway pressure treatment applied in a community setting [J].
Ball, E. M. ;
Banks, M. B. .
SLEEP MEDICINE, 2001, 2 (03) :195-205
[5]   Long-term Effect of Continuous Positive Airway Pressure in Hypertensive Patients with Sleep Apnea [J].
Barbe, Ferran ;
Duran-Cantolla, Joaquin ;
Capote, Francisco ;
de la Pena, Monica ;
Chiner, Eusebi ;
Masa, Juan F. ;
Gonzalez, Monica ;
Marin, Jose M. ;
Garcia-Rio, Francisco ;
Diaz de Atauri, Josefa ;
Teran, Joaquin ;
Mayos, Mercedes ;
Monasterio, Carmen ;
del Campo, Felix ;
Gomez, Sivia ;
Sanchez de la Torre, Manuel ;
Martinez, Montse ;
Montserrat, Jose M. .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181 (07) :718-726
[6]   Sleep apnea in acute cerebrovascular diseases: Final report on 128 patients [J].
Bassetti, C ;
Aldrich, MS .
SLEEP, 1999, 22 (02) :217-223
[7]   Sleep apnea in pat ischemic attack and stroke: A prospective study of 59 patients [J].
Bassetti, C ;
Aldrich, MS ;
Chervin, RD ;
Quint, D .
NEUROLOGY, 1996, 47 (05) :1167-1173
[8]  
Budhiraja R, 2007, SLEEP, V30, P320
[9]   Compliance with nasal CPAP can be improved by simple interventions [J].
Chervin, RD ;
Theut, S ;
Bassetti, C ;
Aldrich, MS .
SLEEP, 1997, 20 (04) :284-289
[10]   Clinical and Polysomnographic Predictors of Short-Term Continuous Positive Airway Pressure Compliance [J].
Collen, Jacob ;
Lettieri, Christopher ;
Kelly, William ;
Roop, Stuart .
CHEST, 2009, 135 (03) :704-709