Clinical Decision Support and Closed-Loop Control for Intensive Care Unit Sedation

被引:15
作者
Haddad, Wassim M. [1 ]
Bailey, James M. [2 ]
Gholami, Behnood [3 ,4 ]
Tannenbaum, Allen R. [5 ,6 ]
机构
[1] Georgia Inst Technol, Sch Aerosp Engn, Atlanta, GA 30332 USA
[2] Northeast Georgia Med Ctr, Dept Anesthesiol, Gainesville, GA 30503 USA
[3] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Neurosurg, Boston, MA 02115 USA
[4] Broad Inst MIT & Harvard, Cambridge, MA USA
[5] Boston Univ, Dept Elect & Comp Engn, Boston, MA 02215 USA
[6] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
关键词
Automated sedation; adaptive control; mechanical ventilation; optimal control; expert systems; clinical decision support; COMPARTMENTAL DYNAMICAL-SYSTEMS; PROPORTIONAL ASSIST VENTILATION; LUNG-PROTECTIVE VENTILATION; QUANTITATIVE EEG-ANALYSIS; OUTPUT-FEEDBACK CONTROL; CRITICALLY-ILL PATIENTS; DRUG DOSING CONTROL; ADAPTIVE-CONTROL; BISPECTRAL INDEX; MECHANICAL VENTILATION;
D O I
10.1002/asjc.701
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Critical care patients undergoing surgery require drug administration to regulate physiological variables such as blood pressure, cardiac output, heart rate, and degree of consciousness. The rate of infusion of each administered drug is critical, requiring constant monitoring and frequent adjustments. Patients in the intensive care unit who require mechanical ventilation due to acute respiratory failure also frequently require the administration of sedative agents. Open-loop control (manual control) by clinical personnel can be tedious, imprecise, time-consuming, and sometimes of poor quality, depending on the skills and judgment of the clinician. Dynamical system pharmacokinetic and pharmacodynamic modeling and closed-loop control system design methodologies can significantly advance our understanding of the wide effects of pharmacological agents and anesthetics, as well as advance the state-of-the-art in active control of drug delivery systems for clinical pharmacology. In this paper, we discuss the challenges and opportunities of clinical decision support and closed-loop control for intensive care unit sedation.
引用
收藏
页码:317 / 339
页数:23
相关论文
共 138 条
[81]  
Li HC, 2011, P AMER CONTR CONF, P3524
[82]   Clinical implementation of advanced control in anaesthesia [J].
Linkens, DA ;
Abbod, MF ;
Peacock, JE .
TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2000, 22 (04) :303-330
[83]   A GENERAL MATHEMATICAL-MODEL FOR RESPIRATORY DYNAMICS RELEVANT TO THE CLINICAL SETTING [J].
MARINI, JJ ;
CROOKE, PS .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (01) :14-24
[84]  
Martin L., 1987, PULMONARY PHYSL CLIN
[85]   SEDATION FOR THE MECHANICALLY VENTILATED PATIENT [J].
MAZZEO, AJ .
CRITICAL CARE CLINICS, 1995, 11 (04) :937-&
[86]  
Mitchell H. B., 2007, Multi-Sensor Data Fusion: an Introduction
[87]   Subject-ventilator synchrony during neural versus pneumatically triggered non-invasive helmet ventilation [J].
Moerer, Onnen ;
Beck, Jennifer ;
Brander, Lukas ;
Costa, Roberta ;
Quintel, Michael ;
Slutsky, Arthur S. ;
Brunet, Fabrice ;
Sinderby, Christer .
INTENSIVE CARE MEDICINE, 2008, 34 (09) :1615-1623
[88]  
Monwar M.M., 2007, International Journal of Applied Mathematics, V36
[89]   The Bispectral Index: Expanded performance for everyday use in the intensive care unit? [J].
Nasraway, SA .
CRITICAL CARE MEDICINE, 2005, 33 (03) :685-687
[90]   How reliable is the Bispectral Index in critically ill patients? A prospective, comparative, single-blinded observer study [J].
Nasraway, SA ;
Wu, EC ;
Kelleher, RM ;
Yasuda, CM ;
Donnelly, AM .
CRITICAL CARE MEDICINE, 2002, 30 (07) :1483-1487