Radiographic endodontic working length estimation: comparison of three digital image receptors

被引:10
作者
Athar, Anas [1 ]
Angelopoulos, Christos [1 ]
Katz, Jerald O. [1 ]
Williams, Karen B. [1 ]
Spencer, Paulette [1 ]
机构
[1] Univ Missouri, Sch Dent, Kansas City, MO USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2008年 / 106卷 / 04期
关键词
D O I
10.1016/j.tripleo.2008.04.031
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. This in vitro study was conducted to evaluate the accuracy of the Schick wireless image receptor compared with 2 other types of digital image receptors for measuring the radiographic landmarks pertinent to endodontic treatment. Study design. Fourteen human cadaver mandibles with retained molars were selected. A fine endodontic file (#10) was introduced into the canal at random distances from the apex and at the apex of the tooth; images were made with 3 different #2-size image receptors: DenOptix storage phosphor plates, Gendex CCD sensor ( wired), and Schick CDR sensor (wireless). Six raters viewed the images for identification of the radiographic apex of the tooth and the tip of a fine (#10) endodontic file. Inter-rater reliability was also assessed. Results. Repeated-measures analysis of variance revealed a significant main effect for the type of image receptor. Raters' error in identifying structures of interest was significantly higher for Denoptix storage phosphor plates, whereas the least error was noted with the Schick CDR sensor. A significant interaction effect was observed for rater and type of image receptor used, but this effect contributed only 6% (P < .01; n(2) = 0.06) toward the outcome of the results. Conclusions. Schick CDR wireless sensor may be preferable to other solid-state sensors, because there is no cable connecting the sensor to the computer. Further testing of this sensor for other diagnostic tasks is recommended, as well as evaluation of patient acceptance. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;106:604-8)
引用
收藏
页码:604 / 608
页数:5
相关论文
共 17 条
[1]   CRITICAL EVALUATION OF SOME METHODS OF DETERMINING TOOTH LENGTH [J].
BRAMANTE, CM ;
BERBERT, A .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1974, 37 (03) :463-473
[2]  
Bridgman J. B., 1995, New Zealand Dental Journal, V91, P62
[3]   Direct digital radiography versus conventional radiography for estimation of canal length in curved canals [J].
Burger, CL ;
Mork, TO ;
Hutter, JW ;
Nicoll, B .
JOURNAL OF ENDODONTICS, 1999, 25 (04) :260-263
[4]  
Caplan DJ, 2002, J DENT RES, V81, pA30
[5]  
Cohen S., 2002, PATHWAYS PULP
[6]   A comparison of 18 different x-ray detectors currently used in dentistry [J].
Farman, AG ;
Farman, TT .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 99 (04) :485-489
[7]  
FORD TRP, 1999, ENDODONTICS CLIN PRA
[8]   RADIOGRAPHIC DETERMINATION OF CANAL LENGTH - DIRECT DIGITAL RADIOGRAPHY VERSUS CONVENTIONAL RADIOGRAPHY [J].
HEDRICK, RT ;
DOVE, SB ;
PETERS, DD ;
MCDAVID, WD .
JOURNAL OF ENDODONTICS, 1994, 20 (07) :320-326
[9]   A SIMPLE AND ACCURATE WAY OF MEASURING ROOT-CANAL LENGTH [J].
INOUE, N ;
SKINNER, DH .
JOURNAL OF ENDODONTICS, 1985, 11 (10) :421-427
[10]   INTERPRETATION OF ENDODONTIC FILE LENGTHS USING RADIO VISIOGRAPHY [J].
LEDDY, BJ ;
MILES, DA ;
NEWTON, CW ;
BROWN, CE .
JOURNAL OF ENDODONTICS, 1994, 20 (11) :542-545