A Study of a Three-Phase Four-Wire Shunt Active Power Filter for Harmonics Mitigation

被引:0
作者
Ayala Maciel, Luis Fernando [1 ]
Monroy Morales, Jose Luis [1 ]
Marroquin Pimentel, Juan Gabriel [1 ]
Campos Gaona, David [2 ]
机构
[1] Inst Tecnol Morelia, Tecnol Nacl Mexico, Dept Ingn Elect, Morelia, Michoacan, Mexico
[2] Univ Strathclyde, Wind Energy & Control Ctr, 99 George St, Glasglow G1 1RD, Scotland
来源
2018 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC) | 2018年
关键词
Active Power Filter; Three Phase Four Wire Systems; Harmonic Compensation; COMPENSATION;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The electrical power quality in three phase four wire systems, feeding nonlinear loads, can be improved by using active power filters (APF) in order to mitigate the total harmonic distortion. Harmonic currents and voltages produced by single phase, non-linear loads, which are connected phase to neutral in a three phase, four wire system, are third order, zero sequence harmonics. These third order, zero sequence harmonic currents, unlike positive and negative sequence harmonic currents, do not cancel but add up arithmetically at the neutral bus, and can be greater than the current of each of the phases. The danger that arises is an excessive overheating of the neutral, since there is no circuit breaker in this conductor, which limits the current, as occurs with the phase conductors. An excessive current in the neutral can also cause an excessive voltage difference between the neutral conductor and ground. This paper presents the theory and design of the control system used to mitigate harmonic problems in three-phase four-wire systems based on a split capacitor topology. Due to split capacitor topology has midpoint between the capacitors, this point can be used for the neutral return path, and thus, the entire neutral current flows through the DC bus capacitors reducing the number of switching devices. Simulation results are shown to validate the proposed procedures.
引用
收藏
页数:6
相关论文
共 15 条
[1]  
Akagi H., 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370), P431, DOI 10.1109/IAS.1999.799991
[2]  
Akagi H., 2017, INSTANTANEOUS POWER, P472, DOI [10.1002/9781119307181, DOI 10.1002/9781119307181]
[3]  
[Anonymous], 2005, PROC EUR C POWER ELE
[4]   An universal active power line conditioner [J].
Aredes, M ;
Heumann, K ;
Watanabe, EH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (02) :545-551
[5]  
Benslimane T, 2006, INT POWER ELECT ELEC, P780
[6]   COMPENSATION STRATEGIES FOR SHUNT ACTIVE-FILTER CONTROL [J].
CAVALLINI, A ;
MONTANARI, GC .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1994, 9 (06) :587-593
[7]  
Fang Zheng Peng, 1998, IEEE Industry Applications Magazine, V4, P21, DOI 10.1109/2943.715502
[8]  
Jianping Ying, 1999, Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99. (Cat. No.99TH8475), P905, DOI 10.1109/PEDS.1999.792827
[9]  
Kanaan H.Y., 2006, Power Electronics, Machines and Drives, P252
[10]  
Karbasforooshan MS, 2017, IEEE IND ELEC, P6389, DOI 10.1109/IECON.2017.8217113