Flow injection-assisted optical sensor for determination of iron(II) and iron(III) in natural water

被引:15
作者
daConceicao, ACL [1 ]
Tena, MT [1 ]
dosSantos, MMC [1 ]
Goncalves, MLS [1 ]
deCastro, MDL [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
flow injection; sensors; iron; waters;
D O I
10.1016/S0003-2670(96)00595-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An approach for speciation of iron (as Fe(II) and Fe(III)) based on integration of retention of the Fe(III)-SCN complex with detection using a conventional spectrophotometer is proposed here. The device (namely, a flow-cell packed with an exchange resin) has been coupled to a flow-injection manifold with inner-coupled injection valves which enables discrimination between Fe(III) and Fe(II) taking advantage of a redox minicolumn housed in the loop of one of the valves. The method thus proposed has good selectivity with a determination limit of 80 mu gl(-1) and affords a determination range of 80-500 mu gl(-1) for Fe(II) plus Fe(III). Application to synthetic and real samples containing both the oxidation states of iron lead to average recoveries of 103% and 101% for Fe(II) and total iron (Fe(II)+ Fe(III)), respectively, thus showing the usefulness of the overall approach.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 20 条
[1]   SANDWICH TECHNIQUES IN FLOW-INJECTION ANALYSIS .2. SIMULTANEOUS DETERMINATION OF IRON(II) AND TOTAL IRON [J].
ALONSO, J ;
BARTROLI, J ;
DELVALLE, M ;
BARBER, R .
ANALYTICA CHIMICA ACTA, 1989, 219 (02) :345-350
[2]   METAL SPECIATION BY FLOW-INJECTION ANALYSIS [J].
BUBNIS, BP ;
STRAKA, MR ;
PACEY, GE .
TALANTA, 1983, 30 (11) :841-844
[3]   FLOW-INJECTION SPECTROPHOTOMETRY FOLLOWED BY ATOMIC-ABSORPTION SPECTROMETRY FOR THE DETERMINATION OF IRON(II) AND TOTAL IRON [J].
BURGUERA, JL ;
BURGUERA, M .
ANALYTICA CHIMICA ACTA, 1984, 161 (JUL) :375-379
[4]  
CANIZARES P, 1996, ANAL CHIM ACTA, V323, P55
[5]  
COSANO JS, 1988, TECN LAB, V147, P32
[6]   SPECIATION WITH UNSEGMENTED CONTINUOUS SYSTEMS [J].
DECASTRO, MDL ;
BRYCE, DW ;
IZQUIERDO, A .
TALANTA, 1995, 42 (09) :1215-1227
[7]   SPECIATION STUDIES BY FLOW-INJECTION ANALYSIS [J].
DECASTRO, MDL .
TALANTA, 1986, 33 (01) :45-50
[8]   DETERMINATION OF IRON(II) AND IRON(III) BY FLOW-INJECTION AND AMPEROMETRIC DETECTION WITH A GLASSY-CARBON ELECTRODE [J].
DIEKER, JW ;
VANDERLINDEN, WE .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :267-274
[9]   APPLICATION OF A REDUCING COLUMN FOR METAL SPECIATION BY FLOW-INJECTION ANALYSIS - SPECTROPHOTOMETRIC DETERMINATION OF IRON(III) AND SIMULTANEOUS DETERMINATION OF IRON(II) AND TOTAL IRON [J].
FAIZULLAH, AT ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1985, 167 (JAN) :225-231
[10]   INTEGRATED RETENTION SPECTROPHOTOMETRIC DETECTION IN FLOW-INJECTION ANALYSIS - DETERMINATION OF IRON IN WATER AND WINE [J].
LAZARO, F ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1989, 219 (02) :231-238