Calibrated 2D Angular Kinematics by Single-Axis Accelerometers: From Inverted Pendulum to N-Link Chain

被引:14
作者
Bagala, Fabio [1 ]
Fuschillo, Valeria Lucia [1 ]
Chiari, Lorenzo [1 ]
Cappello, Angelo [1 ]
机构
[1] Univ Bologna, DEIS, Dept Elect Comp Sci & Syst, I-40136 Bologna, Italy
关键词
Calibration; joint angle; movement analysis; multi-link; single-axis accelerometer; MINIATURE ACCELEROMETERS; MOTION ANALYSIS; JOINT ANGLE; GYROSCOPE; POSITION; SENSORS; BALANCE; GAIT;
D O I
10.1109/JSEN.2011.2107897
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new method for the estimation of multi-link angular kinematics in the sagittal plane, using one single-axis accelerometer (SAA) per segment, is presented in this paper. A preliminary calibration, using SAAs and a reference system (encoder or stereo-photogrammetry), allows the estimation of sensors position and orientation and segment lengths. These parameters are then used to predict the chain kinematics using the SAAs only. To evaluate the method, the algorithm is first tested on a mechanical arm equipped with a reference encoder. A general method for estimating the kinematics of an N-link chain is also provided. Finally, a three-link biomechanical model is applied to a human subject to estimate the joint angles during squat tasks; a stereo-photogrammetric system is used for validation. The results are very close to the reference values. Mean descriptive (predictive) root mean squared error (RMSE) is 0.15 degrees (0.16 degrees) for the inverted pendulum, and 0.39 degrees (0.59 degrees) for the shank, 0.82 degrees (1.06 degrees) for the thigh, 0.87 degrees (1.09 degrees) for the HAT (head-arm-trunk) in the three-link model. The mean value of RMSE without calibration is 1.02 degrees for the inverted pendulum, and 11.01 degrees (shank), 11.39 degrees (thigh) and 12.21 degrees (HAT) in the three-link model. These results suggest that, after the calibration procedure, one SAA per segment is enough to estimate 2D joint angles accurately in a kinematic chain of any number of links.
引用
收藏
页码:479 / 486
页数:8
相关论文
共 21 条
[1]   LEAST-SQUARES FITTING OF 2 3-D POINT SETS [J].
ARUN, KS ;
HUANG, TS ;
BLOSTEIN, SD .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) :699-700
[2]   Inertial sensor-based knee flexion/extension angle estimation [J].
Cooper, Glen ;
Sheret, Ian ;
McMillian, Louise ;
Siliverdis, Konstantinos ;
Sha, Ning ;
Hodgins, Diana ;
Kenney, Laurence ;
Howard, David .
JOURNAL OF BIOMECHANICS, 2009, 42 (16) :2678-2685
[3]   Estimation and visualization of sagittal kinematics of lower limbs orientation using body-fixed sensors [J].
Dejnabadi, Hooman ;
Jolles, Brigitte M. ;
Casanova, Emilio ;
Fua, Pascal ;
Aminian, Kamiar .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (07) :1385-1393
[4]   Gravitational artifact in accelerometric measurements of tremor [J].
Elble, RJ .
CLINICAL NEUROPHYSIOLOGY, 2005, 116 (07) :1638-1643
[5]   Ambulatory measurement of 3D knee joint angle [J].
Favre, J. ;
Jolles, B. M. ;
Aissaoui, R. ;
Aminian, K. .
JOURNAL OF BIOMECHANICS, 2008, 41 (05) :1029-1035
[6]   ANALYSIS OF MEASUREMENTS BASED ON THE SINGULAR VALUE DECOMPOSITION [J].
HANSON, RJ ;
NORRIS, MJ .
SIAM JOURNAL ON SCIENTIFIC AND STATISTICAL COMPUTING, 1981, 2 (03) :363-373
[7]   LEG MOTION ANALYSIS DURING GAIT BY MULTIAXIAL ACCELEROMETRY - THEORETICAL FOUNDATIONS AND PRELIMINARY VALIDATIONS [J].
HAYES, WC ;
GRAN, JD ;
NAGURKA, ML ;
FELDMAN, JM ;
OATIS, C .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :283-289
[8]   An accelerometry-based system for the assessment of balance and postural sway [J].
Kamen, G ;
Patten, C ;
Du, CD ;
Sison, S .
GERONTOLOGY, 1998, 44 (01) :40-45
[9]   Body position can be monitored in 3D using miniature accelerometers and earth-magnetic field sensors [J].
Kemp, B ;
Janssen, AJMW ;
van der Kamp, B .
ELECTROMYOGRAPHY AND MOTOR CONTROL-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 109 (06) :484-488
[10]   Novel approach to ambulatory assessment of human segmental orientation on a wearable sensor system [J].
Liu, Kun ;
Liu, Tao ;
Shibata, Kyoko ;
Inoue, Yoshio ;
Zheng, Rencheng .
JOURNAL OF BIOMECHANICS, 2009, 42 (16) :2747-2752