Sequential detection of Salmonella typhimurium and Bacillus anthracis spores using magnetoelastic biosensors

被引:90
|
作者
Huang, S. [1 ]
Yang, H.
Lakshmanan, R. S.
Johnson, M. L.
Wan, J.
Chen, I. -H. [1 ]
Wikle, H. C., III
Petrenko, V. A. [2 ]
Barbaree, J. M. [1 ]
Chin, B. A.
机构
[1] Auburn Univ, Dept Bot & Microbiol, Auburn, AL 36849 USA
[2] Auburn Univ, Dept Pathobiol, Auburn, AL 36849 USA
来源
BIOSENSORS & BIOELECTRONICS | 2009年 / 24卷 / 06期
关键词
Multiple detection; Magnetoelastic; Biosensor; Phage; Salmonella typhimurium; Bacillus anthracis spores; PHAGE; WIRELESS;
D O I
10.1016/j.bios.2008.09.006
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Multiple phage-based magnetoelastic (ME) biosensors were simultaneously monitored for the detection of different biological pathogens that were sequentially introduced to the measurement system. The biosensors were formed by immobilizing phage and 1 mg/ml BSA (blocking agent) onto the magnetoelastic resonator's surface. The detection system included a reference sensor as a control, an E2 phage-coated sensor specific to S. typhimurium, and a JRB7 phage-coated sensor specific to B. anthracis spores. The sensors were free standing during the test, being held in place by a magnetic field. Upon sequential exposure to single pathogenic solutions. only the biosensor coated with the corresponding specific phage responded. As the cells/spores were captured by the specific phage-coated sensor. the mass of the sensor increased, resulting in a decrease in the sensor's resonance frequency. Additionally, non-specific binding was effectively eliminated by BSA blocking and was verified by the reference sensor, which showed no frequency shift. Scanning electron microscopy was used to visually verify the interaction of each biosensor with its target analyte. The results demonstrate that multiple magnetoelastic sensors may be simultaneously monitored to detect specifically targeted pathogenic species with good selectivity. This research is the first stage of an ongoing effort to simultaneously detect the presence of multiple pathogens in a complex analyte. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1730 / 1736
页数:7
相关论文
共 50 条
  • [21] Characterization of phage-coupled magnetoelastic micro-particles for the detection of Bacillus anthracis Sterne spores
    Wan, Jiehui
    Johnson, Michael L.
    Horikawa, Shin
    Chin, Bryan A.
    Petrenko, Valery A.
    2007 IEEE SENSORS, VOLS 1-3, 2007, : 1085 - 1092
  • [22] Evaluation of phage-based magnetoelastic biosensors for direct detection of Salmonella Typhimurium on spinach leaves
    Park, Mi-Kyung
    Park, Jang Won
    Wikle, Howard C., III
    Chin, Bryan A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 1134 - 1140
  • [23] Detection of Bacillus anthracis spores in soil by PCR
    Sjostedt, A
    Eriksson, U
    Ramisse, V
    Garrigue, H
    FEMS MICROBIOLOGY ECOLOGY, 1997, 23 (02) : 159 - 168
  • [24] The detection of Salmonella typhimurium on shell eggs using phagebased biosensors
    Chai, Yating
    Li, Suiqiong
    Horikawa, Shin
    Shen, Wen
    Park, Mi-kyung
    Vodyanoy, Vitaly J.
    Chin, Bryan A.
    SENSING FOR AGRICULTURE AND FOOD QUALITY AND SAFETY III, 2011, 8027
  • [25] Direct Detection of Salmonella on Fresh Vegetables Using Multiple Magnetoelastic Biosensors
    Li, Suiqiong
    Horikawa, Shin
    Shen, Wen
    Cheng, Z-Y.
    Chin, Bryan A.
    2010 IEEE SENSORS, 2010, : 1066 - 1070
  • [26] Rapid Detection of Bacillus anthracis Spores Using Immunomagnetic Separation and Amperometry
    Waller, David F.
    Hew, Brian E.
    Holdaway, Charlie
    Jen, Michael
    Peckham, Gabriel D.
    BIOSENSORS-BASEL, 2016, 6 (04):
  • [27] Fast and Sensitive Detection of Bacillus anthracis Spores by Immunoassay
    Morel, Nathalie
    Volland, Herve
    Dano, Julie
    Lamourette, Patricia
    Sylvestre, Patricia
    Mock, Michele
    Creminon, Christophe
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2012, 78 (18) : 6491 - 6498
  • [28] Development of an amperometric biosensor for the detection of Bacillus anthracis spores
    Ortatatli, Mesut
    Saatci, Ebru
    Kilic, Zahir
    Kenar, Levent
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2024, 110 (03)
  • [29] Wireless Magnetoelastic Biosensors for the Detection of Salmonella on Fresh Produce
    Chai, Yating
    Horikawa, Shin
    Simonian, Aleksandr
    Dyer, David
    Chin, Bryan A.
    2013 SEVENTH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2013, : 174 - 177
  • [30] Magnetoelastic biosensor for the detection of Salmonella typhimurium in food products
    Rajesh Guntupalli
    Ramji S. Lakshmanan
    Michael L. Johnson
    Jing Hu
    Tung-Shi Huang
    James M. Barbaree
    Vitaly J. Vodyanoy
    Bryan A. Chin
    Sensing and Instrumentation for Food Quality and Safety, 2007, 1 (1):