Sequential detection of Salmonella typhimurium and Bacillus anthracis spores using magnetoelastic biosensors

被引:90
|
作者
Huang, S. [1 ]
Yang, H.
Lakshmanan, R. S.
Johnson, M. L.
Wan, J.
Chen, I. -H. [1 ]
Wikle, H. C., III
Petrenko, V. A. [2 ]
Barbaree, J. M. [1 ]
Chin, B. A.
机构
[1] Auburn Univ, Dept Bot & Microbiol, Auburn, AL 36849 USA
[2] Auburn Univ, Dept Pathobiol, Auburn, AL 36849 USA
来源
BIOSENSORS & BIOELECTRONICS | 2009年 / 24卷 / 06期
关键词
Multiple detection; Magnetoelastic; Biosensor; Phage; Salmonella typhimurium; Bacillus anthracis spores; PHAGE; WIRELESS;
D O I
10.1016/j.bios.2008.09.006
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Multiple phage-based magnetoelastic (ME) biosensors were simultaneously monitored for the detection of different biological pathogens that were sequentially introduced to the measurement system. The biosensors were formed by immobilizing phage and 1 mg/ml BSA (blocking agent) onto the magnetoelastic resonator's surface. The detection system included a reference sensor as a control, an E2 phage-coated sensor specific to S. typhimurium, and a JRB7 phage-coated sensor specific to B. anthracis spores. The sensors were free standing during the test, being held in place by a magnetic field. Upon sequential exposure to single pathogenic solutions. only the biosensor coated with the corresponding specific phage responded. As the cells/spores were captured by the specific phage-coated sensor. the mass of the sensor increased, resulting in a decrease in the sensor's resonance frequency. Additionally, non-specific binding was effectively eliminated by BSA blocking and was verified by the reference sensor, which showed no frequency shift. Scanning electron microscopy was used to visually verify the interaction of each biosensor with its target analyte. The results demonstrate that multiple magnetoelastic sensors may be simultaneously monitored to detect specifically targeted pathogenic species with good selectivity. This research is the first stage of an ongoing effort to simultaneously detect the presence of multiple pathogens in a complex analyte. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1730 / 1736
页数:7
相关论文
共 50 条
  • [1] Multiple Phage-Based Magnetoelastic Biosensors System for the Detection of Salmonella typhimurium and Bacillus anthracis spores
    Huang, S.
    Li, S.
    Yang, H.
    Johnson, M. L.
    Lakshmanan, R. S.
    Chen, I. -H.
    Petrenko, V. A.
    Barbaree, J. M.
    Chin, B. A.
    MATERIALS AND DEVICES FOR SMART SYSTEMS III, 2009, 1129 : 137 - +
  • [2] Phage-based magnetoelastic wireless biosensors for detecting Bacillus anthracis spores
    Wan, Jiehui
    Shu, Huihua
    Huang, Shichu
    Fiebor, Ben
    Chen, I-Hsuan
    Petrenko, Valery A.
    Chin, Bryan A.
    IEEE SENSORS JOURNAL, 2007, 7 (3-4) : 470 - 477
  • [3] Phage coated magnetoelastic micro-biosensors for real-time detection of Bacillus anthracis spores
    Shen, Wen
    Lakshmanan, Ramji S.
    Mathison, Leslie C.
    Petrenko, Valery A.
    Chin, Bryan A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (02) : 501 - 506
  • [4] Detection of Salmonella Typhimurium on Spinach Using Phage-Based Magnetoelastic Biosensors
    Wang, Fengen
    Horikawa, Shin
    Hu, Jiajia
    Wikle, Howard C., III
    Chen, I-Hsuan
    Du, Songtao
    Liu, Yuzhe
    Chin, Bryan A.
    SENSORS, 2017, 17 (02)
  • [5] Detection of Bacillus anthracis spores in water using Biosensors based on magnetostrictive microcantilever coated with phage
    Fu, Liling
    Li, Suiqiong
    Zhang, Kewei
    Cheng, Z. -Y.
    Barbaree, J. M.
    MICRO (MEMS) AND NANOTECHNOLOGIES FOR DEFENSE AND SECURITY, 2007, 6556
  • [6] Direct detection of Salmonella typhimurium on fresh produce using phage-based magnetoelastic biosensors
    Li, Suiqiong
    Li, Yugui
    Chen, Huiqin
    Horikawa, Shin
    Shen, Wen
    Simonian, Aleksandr
    Chin, Bryan A.
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (04): : 1313 - 1319
  • [7] Detection of Salmonella Typhimurium on Fresh Food Produce using Phage-based Magnetoelastic Biosensors
    Li, Suiqiong
    Horikawa, Shin
    Shen, Wen
    Chin, Bryan A.
    CHEMICAL SENSORS 9 -AND- MEMS/NEMS 9, 2010, 33 (08): : 91 - 97
  • [8] Biosensors for the Detection of Bacillus anthracis
    Wang, Dian-Bing
    Cui, Meng-Meng
    Li, Min
    Zhang, Xian-En
    ACCOUNTS OF CHEMICAL RESEARCH, 2021, 54 (24) : 4451 - 4461
  • [9] Detection of Bacillus anthracis spores in liquid using phage-based magnetoelastic micro-resonators
    Wan, Jiehui
    Johnson, Michael L.
    Guntupalli, Rajesh
    Petrenko, Valery A.
    Chin, Bryan A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (02): : 559 - 566
  • [10] Rapid and sensitive magnetoelastic biosensors for the detection of Salmonella typhimurium in a mixed microbial population
    Guntupalli, R.
    Lakshmanan, R. S.
    Hu, J.
    Huang, T. S.
    Barbaree, J. M.
    Vodyanoy, V.
    Chin, B. A.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2007, 70 (01) : 112 - 118