Reliability and Validity of Measuring Acetabular Component Orientation by Plain Anteroposterior Radiographs

被引:93
作者
Lu, Ming [1 ]
Zhou, Yi-Xin [1 ]
Du, Hui [1 ]
Zhang, Ji [1 ]
Liu, Jian [1 ]
机构
[1] Peking Univ, Clin Coll 4, Beijing Jishuitan Hosp, Dept Adult Reconstruct Surg, Beijing 100035, Peoples R China
关键词
TOTAL HIP-ARTHROPLASTY; MEASURING CUP ORIENTATION; CT METHOD; ANTEVERSION; NAVIGATION; POSITION; DISLOCATIONS; REPLACEMENT; VALIDATION; ACCURACY;
D O I
10.1007/s11999-013-3021-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Inaccurate placement of an acetabular cup can cause impingement, dislocation, and accelerated wear. However, there is no universally agreed-on approach to measuring cup position using plain radiographs. Our goal was to evaluate the reliability and validity of measuring the orientation of acetabular components on plain anteroposterior (AP) radiographs. We obtained plain AP radiographs and CT scans for 60 patients who underwent 60 primary total hip arthroplasties (THAs). The method devised by Lewinnek et al. was used to measure the orientation of acetabular components on plain AP radiographs, and three-dimensional (3-D) CT scans were used to measure both the radiographic anteversion angle and the inclination angle. Reliability was evaluated by analysis of the agreement between inter- and intraobserver measurements using plain AP radiographs. Measurements on 3-D CT scans were regarded as the reference standard; validity was assessed by comparing radiographic measurements with the CT scans. Inter- and intraobserver reliability for measuring component orientation on plain AP radiographs was nearly perfect with intraclass correlation coefficients of 0.896 and 0.969 for anteversion and 0.984 and 0.993 for inclination. Measurement of cup inclination angles differed between plain radiographs and CT scans, but the difference was small, and the difference, although statistically significant, probably was not clinically important (2.3A degrees A A +/- A 1.8A degrees, p < 0.001). There was no significant difference between the anteversion as measured on CT scan versus that measured on plain radiographs (p = 0.19). Measurement of the orientation of acetabular components on plain AP radiographs is reliable and accurate compared with measurement on CT. Level II, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:2987 / 2994
页数:8
相关论文
共 30 条
[1]   ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT [J].
ACKLAND, MK ;
BOURNE, WB ;
UHTHOFF, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :409-413
[2]   The rationale for tilt-adjusted acetabular cup navigation [J].
Babisch, Juergen W. ;
Layher, Frank ;
Amiot, Louis-Philippe .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (02) :357-365
[3]   Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty [J].
Barrack, RL ;
Lavernia, C ;
Ries, M ;
Thornberry, R ;
Tozakoglou, E .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (04) :569-+
[4]   Effects of acetabular abduction on cup wear rates in total hip arthroplasty [J].
Del Schutte, H ;
Lipman, AJ ;
Bannar, SM ;
Livermore, JT ;
Ilstrup, D ;
Morrey, BF .
JOURNAL OF ARTHROPLASTY, 1998, 13 (06) :621-626
[5]   Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364
[6]   CT Outperforms Radiography for Determination of Acetabular Cup Version after THA [J].
Ghelman, Bernard ;
Kepler, Christopher K. ;
Lyman, Stephen ;
Della Valle, Alejandro Gonzalez .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (09) :2362-2370
[7]   EVALUATION OF ACETABULAR ANTEVERSION FOLLOWING TOTAL HIP ARTHROPLASTY - NECESSITY OF PROPER CENTERING [J].
GOERGEN, TG ;
RESNICK, D .
BRITISH JOURNAL OF RADIOLOGY, 1975, 48 (568) :259-260
[8]   RADIOGRAPHIC CALCULATION OF ANTEVERSION IN ACETABULAR PROSTHESES [J].
HASSAN, DM ;
JOHNSTON, GHF ;
DUST, WNC ;
WATSON, LG ;
CASSIDY, D .
JOURNAL OF ARTHROPLASTY, 1995, 10 (03) :369-372
[9]   Factors predisposing to dislocation after primary total hip arthroplasty - A multivariate analysis [J].
Jolles, BM ;
Zangger, P ;
Leyvraz, PF .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :282-288
[10]   Position of the acetabular cup - accuracy of radiographic calculation compared to CT-based measurement [J].
Kalteis, T ;
Handel, M ;
Herold, T ;
Perlick, L ;
Paetzel, C ;
Grifka, J .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 58 (02) :294-300