Comparison of Wavefront-guided and Best Conventional Scleral Lenses after Habituation in Eyes with Corneal Ectasia

被引:45
作者
Hastings, Gareth D. [1 ]
Applegate, Raymond A. [1 ]
Lan Chi Nguyen [1 ]
Kauffman, Matthew J. [1 ]
Hemmati, Roxana T. [1 ,2 ]
Marsack, Jason D. [1 ]
机构
[1] Univ Houston, Coll Optometry, Visual Opt Inst, Houston, TX 77004 USA
[2] Baylor Coll Med, Houston, TX 77030 USA
关键词
SOFT CONTACT-LENSES; HIGHER-ORDER ABERRATIONS; PHASE-TRANSFER-FUNCTION; IMAGE QUALITY; VISUAL PERFORMANCE; KERATOCONIC EYES; OPTICAL-QUALITY; ON-EYE; OBJECTIVE REFRACTION; RGP LENS;
D O I
10.1097/OPX.0000000000001365
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE: Visual performance with wavefront-guided (WFG) contact lenses has only been reported immediately after manufacture without time for habituation, and comparison has only beenmade with clinically unrefined predicate conventional lenses. We present comparisons of habitual corrections, best conventional scleral lenses, and WFG scleral lenses after habituation to all corrections. PURPOSE The purpose of this study was to compare, in a crossover design, optical and visual performance of eyes with corneal ectasias wearing dispensed best conventional scleral lens corrections and dispensed individualized WFG scleral lens corrections. METHODS Ten subjects (20 eyes) participated in a randomized crossover study where best conventional scleral lenses and WFG scleral lenses (customized through the fifth radial order) were worn for 8 weeks each. These corrections, as well as each subject's habitual correction and normative data for normal eyes, were compared using (1) residual higher-order aberrations (HORMS), (2) visual acuity (VA), (3) letter contrast sensitivity (CS), and (4) visual image quality (logarithm of the visual Strehl ratio, or logVSX). Correlations were performed between Pentacam biometric measures and gains provided by WFG lenses. RESULTS Mean HORMS was reduced by 48% from habitual to conventional and 43% from conventional to WFG. Mean logMAR VA improved from habitual (+0.12) to conventional (-0.03) and further with WFG (-0.09); six eyes gained greater than one line with WFG over conventional. Area under the CS curve improved by 26% from habitual to conventional and 14% from conventional to WFG. The percentage of the eyes achieving normal levels were as follows: HORMS, 40% for conventional and 85% for WFG; VA, 50% for conventional and 85% for WFG; and CS, 60% for conventional and 90% for WFG. logVSX improved by 16% from habitual to conventional and 25% further with WFG. Reduction in aberrations with WFG lenses best correlated with posterior cornea radius of curvature. CONCLUSIONS Visual performance was superior to that reported with nonhabituated WFG lens wear. With WFG lenses, HORMS and logVSX significantly improved, allowing more eyes to reach normal levels of optical and visual performance compared with conventional lenses.
引用
收藏
页码:238 / 247
页数:10
相关论文
共 56 条
[11]   Simulated optical performance of custom wavefront soft contact lenses for keratoconus [J].
De Brabander, J ;
Chateau, N ;
Marin, G ;
Lopez-Gil, N ;
Van der Worp, E ;
Benito, A .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (09) :637-643
[12]   VISUAL-ACUITY CHANGES THROUGHOUT ADULTHOOD IN NORMAL, HEALTHY EYES - SEEING BEYOND 6/6 [J].
ELLIOTT, DB ;
YANG, KCH ;
WHITAKER, D .
OPTOMETRY AND VISION SCIENCE, 1995, 72 (03) :186-191
[13]   Method for optimizing the correction of the eye's higher-order aberrations in the presence of decentrations [J].
Guirao, A ;
Cox, IG ;
Williams, DR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (01) :126-128
[14]   Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations [J].
Guirao, A ;
Williams, DR ;
Cox, IG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (05) :1003-1015
[15]   The Impact of the Boston Ocular Surface Prosthesis on Wavefront Higher-Order Aberrations [J].
Gumus, Koray ;
Gire, Anisa ;
Pflugfelder, Stephen C. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (04) :682-690
[16]   Normative best-corrected values of the visual image quality metric VSX as a function of age and pupil size [J].
Hastings, Gareth D. ;
Marsack, Jason D. ;
Thibos, Larry N. ;
Applegate, Raymond A. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2018, 35 (05) :732-739
[17]   Is an objective refraction optimised using the visual Strehl ratio better than a subjective refraction? [J].
Hastings, Gareth D. ;
Marsack, Jason D. ;
Nguyen, Lan Chi ;
Cheng, Han ;
Applegate, Raymond A. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2017, 37 (03) :317-325
[18]  
Ho Arthur, 2003, Eye Contact Lens, V29, pS182
[19]  
Jeong TM, 2006, J KOREAN PHYS SOC, V49, P121
[20]   Optical quality and visual performance with customised soft contact lenses for keratoconus [J].
Jinabhai, Amit ;
O'Donnell, Clare ;
Tromans, Cindy ;
Radhakrishnan, Hema .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2014, 34 (05) :528-539