Use of Maximum Intensity Projections (MIPs) for Target Outlining in 4DCT Radiotherapy Planning

被引:76
作者
Muirhead, Rebecca [1 ]
McNee, Stuart G. [1 ]
Featherstone, Carrie [1 ]
Moore, Karen [1 ]
Muscat, Sarah [1 ]
机构
[1] Beatson W Scotland Canc Ctr, Glasgow G12 0YN, Lanark, Scotland
关键词
4DCT scans; Maximum intensity projections; Lung Cancer; Internal target volume;
D O I
10.1097/JTO.0b013e31818e5db7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Four-dimensional computed tomography (4DCT) is Currently being introduced to radiotherapy centers worldwide. for use in radical radiotherapy planning for non-small cell lung cancer (NSCLC). A significant drawback is the time required to delineate 10 individual CT scans for each patient. Every department will hence ask the question if the single Maximum Intensity Projection (MIP) scan can be used as in alternative. Although the problems regarding the use of the MIP in node-positive disease have been discussed in the literature, a comprehensive study assessing its use has not been published. We compared an internal target volume (ITV) created using the MIP to an ITV created from the composite volume of 10 clinical target volumes (CTVs) delineated on the 10 phases of the 4DCT. Methods: 4DCT data was collected from 14 patients with NSCLC. In each patient, the ITV was delineated on the MIP image (ITV_MIP) and a composite ITV created from the 10 CTVs delineated on each of the 10 scans in the dataset. The structures were compared by assessment of volumes of overlap and exclusion. Results: There was a median of 19.0% (range, 5.5-35.4%) of the volume of ITV_10phase not enclosed by the ITV_MIP, demonstrating that the use of the MIP could result in under-treatment of disease. In contrast only a very small amount of the ITV_MIP was not enclosed by the ITV_10phase (median of 2.3%, range, 0.4-9.8%). indicating the ITV_10phase covers almost all of the tumor as identified by MIP. Although there were only two Stage I patients, both demonstrated very similar ITV_10phase and ITV_MIP volumes. These finding suggest that Stage I NSCLC tumors could be outlined on the MIP alone. In Stage II and III tumors the ITV_10phase would be more reliable. Conclusions: To prevent under-treatment of disease, the MIP image can only be used for delineation in Stage I tumors.
引用
收藏
页码:1433 / 1438
页数:6
相关论文
共 28 条
[1]   Evaluation of the influence of breathing on the movement and modeling of lung tumors [J].
Allen, AM ;
Siracuse, KM ;
Hayman, JA ;
Balter, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (04) :1251-1257
[2]   An "in silico" clinical trial comparing free breathing, slow and respiration correlated computed tomography in lung cancer patients [J].
Bosmans, Geert ;
Buijsen, Jeroen ;
Dekker, Andre ;
Velders, Marije ;
Boersma, Liesbeth ;
De Ruysscher, Dirk ;
Minken, Andre ;
Lambin, Philippe .
RADIOTHERAPY AND ONCOLOGY, 2006, 81 (01) :73-80
[3]   Tumor location cannot predict the mobility of lung tumors: A 3D analysis of data generated from multiple CT scans [J].
de Koste, JRV ;
Lagerwaard, FJ ;
Nijssen-Visser, MRJ ;
Graveland, WJ ;
Senan, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02) :348-354
[4]   Selective mediastinal node irradiation based on FDG-PET scan data in patients with non-small-cell lung cancer: A prospective clinical study [J].
De Ruysscher, D ;
Wanders, S ;
Van Haren, E ;
Hochstenbag, M ;
Geeraedts, W ;
Utama, I ;
Simons, J ;
Dohmen, J ;
Rhami, A ;
Buell, U ;
Thimister, P ;
Snoep, G ;
Boersma, L ;
Verschueren, T ;
Van Baardwijk, A ;
Minken, A ;
Bentzen, SM ;
Lambin, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04) :988-994
[5]   Assessment of intrafraction mediastinal and hilar lymph node movement and comparison to lung tumor motion using four-dimensional CT [J].
Donnelly, Eric D. ;
Parikh, Parag J. ;
Lu, Wei ;
Zhao, Tianyu ;
Lechleiter, Kristen ;
Nystrom, Michelle ;
Hubenschmidt, James P. ;
Low, Daniel A. ;
Bradley, Jeffrey D. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (02) :580-588
[6]  
EZHIL M, 2007, INT J RADIAT ONCOL, V69, pS2511
[7]   Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Ling, CC .
MEDICAL PHYSICS, 2003, 30 (01) :88-97
[8]   Evaluation of microscopic tumor extension in non-small-cell lung cancer for three-dimensional conformal radiotherapy planning [J].
Giraud, P ;
Antoine, M ;
Larrouy, A ;
Milleron, B ;
Callard, P ;
De Rycke, Y ;
Carette, MF ;
Rosenwald, JC ;
Cosset, JM ;
Housset, M ;
Touboul, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04) :1015-1024
[9]   Current status of PET/CT for tumour volume definition in radiotherapy treatment planning for non-small cell lung cancer (NSCLC) [J].
Greco, Carlo ;
Rosenzweig, Kenneth ;
Cascini, Giuseppe Lucio ;
Tamburrini, Oscar .
LUNG CANCER, 2007, 57 (02) :125-134
[10]   Clinicopathologic analysis of microscopic extension in lung adenocarcinoma: Defining clinical target volume for radiotherapy [J].
Grills, Inga S. ;
Fitch, Dwight L. ;
Goldstein, Neal S. ;
Yan, Di ;
Chmielewski, Gary W. ;
Welsh, Robert J. ;
Kestin, Larry L. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (02) :334-341