The usefulness of cone-beam computed tomography gray values for alveolar bone linear measurements

被引:5
|
作者
Padala, Soumya [1 ]
Tee, Boon Ching [2 ]
Beck, Frank M. [2 ]
Elias, Kathy [3 ]
Kim, Do-Gyoon [4 ]
Sun, Zongyang [4 ]
机构
[1] Midwestern Univ, Coll Dent Med, Downers Grove, IL 60515 USA
[2] Ohio State Univ, Coll Dent, Div Biosci, Columbus, OH 43210 USA
[3] Univ Texas Houston, Sch Dent, Pediat Dent, Houston, TX USA
[4] Ohio State Univ, Coll Dent, Div Orthodont, 4088 Postle Hall,305 West Twelfth Ave, Columbus, OH 43210 USA
关键词
CBCT; Alveolar bone; Linear measurement; Gray values; ACCURACY; NUMBER;
D O I
10.2319/060617-379.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To test a proof-of-concept that the accuracy and reliability of alveolar bone height measurements from orthodontic grade (large field-of-view [FOV], large voxel-size) cone-beam computed tomography (CBCT) images may be improved by using pixel gray values. Materials and Methods: Twenty fresh cadaver pig heads underwent CBCT scans (17 x 23 cm FOV, 0.4-mm voxel size). Buccal alveolar bone heights of maxillary first molars were measured using the conventional vision-based (VB) and the proposed gray value-assisted (GVA) methods. The GVA methods entailed localization of landmarks through observation of gray value pattern changes across tissue boundaries followed by mathematical calculation of distances between landmark pixels. Interrater reliability and accuracy of CBCT measurements made by all methods were statistically analyzed by comparing with physical measurements (gold standards). Results: The interrater reliability of CBCT measurements made by GVA methods was comparable to physical measurements but higher than those made by the VB method. The GVA (bend-down pattern) method yielded average measurements similar to physical measurements, while those obtained by the VB and the GVA (straight pattern) methods were significantly larger (repeated measures analysis of variance, P < .001). The GVA (bend-down pattern) method also produced significantly more measurements within one voxel size of physical measurements than did the VB and GVA (straight pattern) methods (Chi-square tests, P < .017). Conclusions: These data confirm a concept that local gray value change patterns may be used to improve the accuracy and reliability of alveolar bone height measurement from large FOV and large voxel-size CBCT images.
引用
收藏
页码:227 / 232
页数:6
相关论文
共 50 条
  • [31] Repeatability and effect of different voxel sizes on linear and volumetric tooth and pulp measurements using cone-beam computed tomography
    Ozdede, Melih
    Akay, Gulsun
    Karadag Atas, Ozge
    Koc, Emirhan Korhan
    Yalcin, Osman
    Gungor, Kahraman
    BMC ORAL HEALTH, 2024, 24 (01):
  • [32] Reliability assessment of craniofacial and airway measurements: a comparative study between multidetector computed tomography and cone-beam computed tomography
    Sun, Jui-Sheng
    Hung, Min-Chih
    Hsieh, Chi-Yeh
    Lin, Shih-Ying
    Tai, Han-Cheng
    Chang, Jenny Zwei-Chieng
    ANGLE ORTHODONTIST, 2025, 95 (01) : 57 - 77
  • [33] Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations
    Tomasi, C.
    Bressan, E.
    Corazza, B.
    Mazzoleni, S.
    Stellini, E.
    Lith, A.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (04) : 244 - 250
  • [34] Reliability of Voxel Gray Values in Cone Beam Computed Tomography for Preoperative Implant Planning Assessment
    Parsa, Azin
    Ibrahim, Norliza
    Hassan, Bassam
    Motroni, Alessandro
    van der Stelt, Paul
    Wismeijer, Daniel
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (06) : 1438 - 1442
  • [35] Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values
    Kumar, Rashmit
    Punnoose, Kurian
    Chikkanna, Meenakumari
    Gunturu, Srikanth
    Alrifai, Mosa Mohammad
    Al Zahrani, Abdulghani Saeed
    Babu, J. Suresh
    Swarnalatha, C.
    Nayyar, Abhishek Singh
    ADVANCED BIOMEDICAL RESEARCH, 2025, 14 (01):
  • [36] Mandibular alveolar bone thickness in untreated Class I subjects with different vertical skeletal patterns: a cone-beam computed tomography study
    Formosa, Joseph
    Zou, Min
    Chung, Chun-Hsi
    Boucher, Normand S.
    Li, Chenshuang
    ANGLE ORTHODONTIST, 2023, 93 (06) : 683 - 694
  • [37] Endodontic Application of Cone-Beam Computed Tomography in South Korea
    Kim, Seonah
    JOURNAL OF ENDODONTICS, 2012, 38 (02) : 153 - 157
  • [38] Cone-beam computed tomography airway measurements: Can we trust them?
    Obelenis Ryan, Daniel Patrick
    Bianchi, Jonas
    Ignacio, Jaqueline
    Wolford, Larry Miller
    Goncalves, Joao Roberto
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2019, 156 (01) : 53 - 60
  • [39] The importance of cone-beam computed tomography in endodontic therapy: A review
    Kolarkodi, Shaul Hameed
    SAUDI DENTAL JOURNAL, 2023, 35 (07) : 780 - 784
  • [40] Movement of mandibular molar into edentulous alveolar ridge: A cone-beam computed tomography study
    Dutra dos Santos, Patricia Bittencourt
    Herrera Sanches, Francyle Simoes
    Ferreira, Marcos Cezar
    Pompeia Fraga de Almeida, Ana Lucia
    Janson, Guilherme
    Garib, Daniela
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 151 (05) : 907 - 913