The usefulness of cone-beam computed tomography gray values for alveolar bone linear measurements

被引:5
|
作者
Padala, Soumya [1 ]
Tee, Boon Ching [2 ]
Beck, Frank M. [2 ]
Elias, Kathy [3 ]
Kim, Do-Gyoon [4 ]
Sun, Zongyang [4 ]
机构
[1] Midwestern Univ, Coll Dent Med, Downers Grove, IL 60515 USA
[2] Ohio State Univ, Coll Dent, Div Biosci, Columbus, OH 43210 USA
[3] Univ Texas Houston, Sch Dent, Pediat Dent, Houston, TX USA
[4] Ohio State Univ, Coll Dent, Div Orthodont, 4088 Postle Hall,305 West Twelfth Ave, Columbus, OH 43210 USA
关键词
CBCT; Alveolar bone; Linear measurement; Gray values; ACCURACY; NUMBER;
D O I
10.2319/060617-379.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To test a proof-of-concept that the accuracy and reliability of alveolar bone height measurements from orthodontic grade (large field-of-view [FOV], large voxel-size) cone-beam computed tomography (CBCT) images may be improved by using pixel gray values. Materials and Methods: Twenty fresh cadaver pig heads underwent CBCT scans (17 x 23 cm FOV, 0.4-mm voxel size). Buccal alveolar bone heights of maxillary first molars were measured using the conventional vision-based (VB) and the proposed gray value-assisted (GVA) methods. The GVA methods entailed localization of landmarks through observation of gray value pattern changes across tissue boundaries followed by mathematical calculation of distances between landmark pixels. Interrater reliability and accuracy of CBCT measurements made by all methods were statistically analyzed by comparing with physical measurements (gold standards). Results: The interrater reliability of CBCT measurements made by GVA methods was comparable to physical measurements but higher than those made by the VB method. The GVA (bend-down pattern) method yielded average measurements similar to physical measurements, while those obtained by the VB and the GVA (straight pattern) methods were significantly larger (repeated measures analysis of variance, P < .001). The GVA (bend-down pattern) method also produced significantly more measurements within one voxel size of physical measurements than did the VB and GVA (straight pattern) methods (Chi-square tests, P < .017). Conclusions: These data confirm a concept that local gray value change patterns may be used to improve the accuracy and reliability of alveolar bone height measurement from large FOV and large voxel-size CBCT images.
引用
收藏
页码:227 / 232
页数:6
相关论文
共 50 条
  • [21] Convolutional neural network-based automated maxillary alveolar bone segmentation on cone-beam computed tomography images
    Fontenele, Rocharles Cavalcante
    Gerhardt, Mauricio do Nascimento
    Picoli, Fernando Fortes
    Van Gerven, Adriaan
    Nomidis, Stefanos
    Willems, Holger
    Freitas, Deborah Queiroz
    Jacobs, Reinhilde
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (06) : 565 - 574
  • [22] Reliability of Linear and Curvilinear Measurements on Cone-Beam Computed Tomography Images for the Evaluation of Implant Sites and Jaw Pathologies
    Kumar, Mathangi
    Madi, Medhini
    Pentapati, Kalyana Chakravarthy
    Vineethaie, Ravindranath
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2021, 21 : 1 - 9
  • [23] Clinical guidelines for dental cone-beam computed tomography
    Hayashi, Takafumi
    Arai, Yoshinori
    Chikui, Toru
    Hayashi-Sakai, Sachiko
    Honda, Kazuya
    Indo, Hiroko
    Kawai, Taisuke
    Kobayashi, Kaoru
    Murakami, Shumei
    Nagasawa, Masako
    Naitoh, Munetaka
    Nakayama, Eiji
    Nikkuni, Yutaka
    Nishiyama, Hideyoshi
    Shoji, Noriaki
    Suenaga, Shigeaki
    Tanaka, Ray
    ORAL RADIOLOGY, 2018, 34 (02) : 89 - 104
  • [24] Method of visualisation influences accuracy of measurements in cone-beam computed tomography
    Patcas, Raphael
    Angst, Christine
    Kellenberger, Christian J.
    Schaetzle, Marc A.
    Ullrich, Oliver
    Markic, Goran
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (07) : 1277 - 1283
  • [25] Quantification of bone microstructure in the wrist using cone-beam computed tomography
    Mys, Karen
    Stockmans, Filip
    Vereecke, Evie
    van Lenthe, G. Harry
    BONE, 2018, 114 : 206 - 214
  • [26] Comparison of Pixel Values of Maxillary Sinus Grafts and Adjacent Native Bone With Cone-Beam Computed Tomography
    Nishimura, Danielle Ayumi
    Aoki, Eduardo Massaharu
    Abdala Junior, Reinaldo
    Arita, Emiko Saito
    Pinhata-Baptista, Otavio Henrique
    Tateno, Ricardo Yudi
    Correa, Luciana
    Gonzalez Cortes, Arthur Rodriguez
    IMPLANT DENTISTRY, 2018, 27 (06) : 667 - 671
  • [27] Cone-beam computed tomography performance in measuring periodontal bone loss
    Yang, Jingmei
    Li, Xinyi
    Duan, Dingyu
    Bai, Lin
    Zhao, Lei
    Xu, Yi
    JOURNAL OF ORAL SCIENCE, 2019, 61 (01) : 61 - 66
  • [28] Evaluation of the anatomical measurements of the temporomandibular joint by cone-beam computed tomography
    Ocak, M.
    Sargon, M. F.
    Orhan, K.
    Bilecenoglu, B.
    Geneci, F.
    Uzuner, M. B.
    FOLIA MORPHOLOGICA, 2019, 78 (01) : 174 - 181
  • [29] Alveolar bone thickness around maxillary central incisors of different inclination assessed with cone-beam computed tomography
    Tian, Yu-lou
    Liu, Fang
    Sun, Hong-jing
    Lv, Pin
    Cao, Yu-ming
    Yu, Mo
    Yue, Yang
    KOREAN JOURNAL OF ORTHODONTICS, 2015, 45 (05) : 245 - 252
  • [30] Detection of alveolar bone defects with three different voxel sizes of cone-beam computed tomography: an in vitro study
    Dong, Ting
    Yuan, Lingjun
    Liu, Lu
    Qian, Yifeng
    Xia, Lunguo
    Ye, Niansong
    Fang, Bing
    SCIENTIFIC REPORTS, 2019, 9 (1)