Dissolved oxygen sensor based on cobalt tetrasulphonated phthalocyanine immobilized in poly-L-lysine film onto glassy carbon electrode

被引:63
作者
Luz, RDS
Damos, FS
Tanaka, AA
Kubota, LT
机构
[1] Univ Estadual Campinas, Inst Chem, Dept Cent Analyt, BR-13084971 Campinas, SP, Brazil
[2] Univ Fed Maranhao, Dept Chem, BR-65085040 Sao Luis, MA, Brazil
基金
巴西圣保罗研究基金会;
关键词
sensor; dissolved oxygen; cobalt tetrasulphonated phthalocyanine; poly-L-lysine;
D O I
10.1016/j.snb.2005.07.063
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and efficient method for determining dissolved oxygen at pH 6.5 is proposed using differential pulse voltammetry (DPV) and chronoamperometry. The sensor was prepared by modifying a glassy carbon (GC) electrode surface with a cobalt tetrasulphonated phthalocyanine (CoTSPc) immobilized in a poly-L-lysine (PLL) film. This sensor showed excellent catalytic activity and stability for oxygen reduction. With this modified electrode the reduction potential of the oxygen was shifted about 200 mV toward less negative value, presenting a peak current much higher than those measured on a bare GC electrode. The linear response range, sensitivity and detection limit obtained were, respectively, 0.2-8.0 mg l(-1), 11.0 mu A l mg(-1) cm(-2) and 96 mu g l(-1) for chronoamperometry and 0.2-8.0 mg l(-1), 18.3 mu A l mg(-1) cm(-2) and 72 mu g l(-1) for DPV. The repeatability and reproductibility of the proposed sensor evaluated in term of relative standard deviation were, respectively, 4.5% and 4.8% for 10 measurements of a 8.0 mg l(-1) oxygen solution. The number of electrons involved in oxygen reduction, the heterogenous rate constant (k) and the diffusion coefficient (D.) value were evaluated by cyclic voltammetry and with a rotating disk electrode (RDE). These studies showed that two electrons are involved in the oxygen reduction. An average value of the heterogenous rate constant was found to be 4.25 x 10(4) mol(-1) l s(-1) and the diffusion coefficient was 2.0 x 10(-5) cm(2) s(-1). (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1019 / 1027
页数:9
相关论文
共 42 条
  • [1] Electrocatalytic oxidation of hydrazine on a carbon paste electrode modified by hybrid hexacyanoferrates of copper and cobalt films
    Abbaspour, A
    Kamyabi, MA
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 576 (01): : 73 - 83
  • [2] ADZIC RR, 1998, ELECTROANALYSIS
  • [3] ANDRIEUX CP, 1978, J ELECTROANAL CHEM, V93, P163, DOI 10.1016/S0022-0728(78)80230-7
  • [4] [Anonymous], 1987, ANALYST, V112, P199
  • [5] Oxygen reduction reaction in acid medium at iron phthalocyanine dispersed on high surface area carbon substrate:: tolerance to methanol, stability and kinetics
    Baranton, S
    Coutanceau, C
    Roux, C
    Hahn, F
    Léger, JM
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 577 (02) : 223 - 234
  • [6] Mg-Al hydrotalcite-like compounds containing iron-phthalocyanine complex: effect of aluminum substitution on the complex adsorption features and catalytic activity
    Barbosa, CAS
    Dias, PM
    Ferreira, AMD
    Constantino, VRL
    [J]. APPLIED CLAY SCIENCE, 2005, 28 (1-4) : 147 - 158
  • [7] BARD AJ, 1980, ELECTROCHEMICAL METH
  • [8] Enhancement of oxygen electroreduction activity via surface modification of carbon supported ruthenium nanoparticles: A new class of electrocatalysts
    Bron, M
    Bogdanoff, P
    Fiechter, S
    Tributsch, H
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 578 (02) : 339 - 344
  • [9] Reactivity of electrodes modified with substituted metallophthalocyanines.: Correlations with redox potentials, Hammett parameters and donor-acceptor intermolecular hardness
    Cárdenas-Jirón, GI
    Gulppi, MA
    Caro, CA
    del Río, R
    Páez, M
    Zagal, JH
    [J]. ELECTROCHIMICA ACTA, 2001, 46 (20-21) : 3227 - 3235
  • [10] SPECTROSCOPIC INVESTIGATIONS OF POLYMER-MODIFIED ELECTRODES CONTAINING COBALT PHTHALOCYANINE - APPLICATION TO THE STUDY OF OXYGEN REDUCTION AT SUCH ELECTRODES
    COUTANCEAU, C
    RAKOTONDRAINIBE, A
    CROUIGNEAU, P
    LEGER, JM
    LAMY, C
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 386 (1-2): : 173 - 182