Simultaneous detection of multiple viruses based on chemiluminescence and magnetic separation

被引:174
作者
Ali, Zeeshan [1 ,2 ]
Wang, Jiuhai [1 ]
Tang, Yongjun [2 ]
Liu, Bin [3 ]
He, Nongyue [1 ,4 ]
Li, Zhiyang [5 ]
机构
[1] Southeast Univ, Sch Biol Sci & Med Engn, State Key Lab Bioelect, Nanjing 210096, Jiangsu, Peoples R China
[2] Shenzhen Polytech, Sch Appl Chem & Biotechnol, Shenzhen 518055, Peoples R China
[3] Nanjing Med Univ, Sch Basic Med Sci, Dept Biomed Engn, Nanjing 210029, Jiangsu, Peoples R China
[4] Hunan Univ Technol, Hunan Key Lab Green Packaging & Applicat Biol Nan, Zhuzhou 412007, Peoples R China
[5] Nanjing Univ, Dept Clin Lab, Sch Med, Affiliated Drum Tower Hosp, Nanjing 210008, Jiangsu, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
HEPATITIS-B-VIRUS; MICROARRAY-BASED DETECTION; COLORIMETRIC DETECTION; SENSITIVE DETECTION; NUCLEIC-ACIDS; C VIRUS; NANOPARTICLES; DNA; ASSAY; RNA;
D O I
10.1039/c6bm00527f
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Nucleic acid testing (NAT) based methods are more sensitive and specific, and are preferred over enzyme immunoassays. Different NAT based protocols have been designed to detect multiple pathogens in order to reduce the inherent high cost for detection. However, these assays do not reliably detect a large number of pathogens at once. In this report, a DNA hybridization based chemiluminescence detection method has been proposed for reliable detection of multiple pathogens. The idea was practically demonstrated by carrying out simultaneous extraction and amplification of hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV-1 group M, herein referred to as HIV) through the one step multiplex reverse transcription polymerase chain reaction (RT-PCR). A detailed study was conducted to optimize the factors which could affect the chemiluminescence signal. The probes for HBV, HCV, and HIV demonstrated higher specificity by only capturing their respective target sequence. 10 viral copies per mL of serum were detected in the monoplex detection protocol for HBV, HCV, and HIV, respectively. However, when the sensitivity of each virus was analyzed in the presence of higher loads of other viruses in the multiplex detection assay, the assay finally detected 10 HBV copies, 10 HCV copies, and 100 HIV copies per microliter of serum. The use of silica modified magnetic nanoparticles during nucleic acid extraction and carboxyl coated magnetic nanoparticles during the chemiluminescence step can help modify this system into an automated platform for high throughput applications.
引用
收藏
页码:57 / 66
页数:10
相关论文
共 42 条
  • [1] Mini review: Current molecular methods for the detection and quantification of hepatitis B virus, hepatitis C virus, and human immunodeficiency virus type 1
    Albertoni, Guilherme
    Batista Castelo Girao, Manoel Joao
    Schor, Nestor
    [J]. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2014, 25 : 145 - 149
  • [2] Magnetic particles for the separation and purification of nucleic acids
    Berensmeier, Sonja
    [J]. APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2006, 73 (03) : 495 - 504
  • [3] CHEMI-LUMINESCENCE LIGHTS UP
    BRONSTEIN, I
    MCGRATH, P
    [J]. NATURE, 1989, 338 (6216) : 599 - 600
  • [4] Evaluation of a transcription-mediated ampliftication-based HCV and HIV-1 RNA duplex assay for screening individual blood donations: a comparison with a minipool testing system
    Candotti, D
    Richetin, A
    Cant, B
    Temple, J
    Sims, C
    Reeves, I
    Barbara, JAJ
    Allain, JP
    [J]. TRANSFUSION, 2003, 43 (02) : 215 - 225
  • [5] Simultaneous detection of multiplex-amplified human immunodeficiency virus type 1 RNA, hepatitis C virus RNA, and hepatitis B virus DNA using a flow cytometer microsphere-based hybridization assay
    Defoort, JP
    Martin, M
    Casano, B
    Prato, S
    Camilla, C
    Fert, V
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (03) : 1066 - 1071
  • [6] Nucleic acid testing (NAT) in high prevalence-low resource settings
    El Ekiaby, Magdy
    Lelie, Nico
    Allain, Jean-Pierre
    [J]. BIOLOGICALS, 2010, 38 (01) : 59 - 64
  • [7] Detecting minimal traces of DNA using DNA covalently attached to superparamagnetic nanoparticles and direct PCR-ELISA
    Fuentes, M
    Mateo, C
    Rodriguez, A
    Casqueiro, M
    Tercero, JC
    Riese, HH
    Fernández-Lafuente, R
    Guisán, JM
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) : 1574 - 1580
  • [8] A rapid assay for Hendra virus IgG antibody detection and its titre estimation using magnetic nanoparticles and phycoerythrin
    Gao, Yuan
    Pallister, Jackie
    Lapierre, Florian
    Crameri, Gary
    Wang, Lin-Fa
    Zhu, Yonggang
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2015, 222 : 170 - 177
  • [9] Simultaneous detection of HCV and HIV-1 by SYBR Green real time multiplex RT-PCR technique in plasma samples
    Gibellini, Davide
    Gardini, Federica
    Vitone, Francesca
    Schiavone, Pasqua
    Furlini, Giuliano
    Re, Maria Carla
    [J]. MOLECULAR AND CELLULAR PROBES, 2006, 20 (3-4) : 223 - 229
  • [10] Pt nanopartictes functionalized with nucleic acid act as catalytic labels for the chemiluminescent detection of DNA and proteins
    Gill, Ron
    Polsky, Ronen
    Willner, Itamar
    [J]. SMALL, 2006, 2 (8-9) : 1037 - 1041