A New High-Frequency Injection Method for Sensorless Control of Doubly Fed Induction Machines

被引:27
作者
Xu, Longya [1 ]
Inoa, Ernesto [1 ]
Liu, Yu [1 ]
Guan, Bo [1 ]
机构
[1] Ohio State Univ, Dept Elect & Comp Engn, Columbus, OH 43210 USA
关键词
Doubly fed induction machines; fault ride through; high-frequency signal injection; power distribution faults; sensorless control; wind power generation; REACTIVE POWER-CONTROL; ORIENTED CONTROL; CONTROL STRATEGY; GENERATOR; OBSERVER; MOTOR;
D O I
10.1109/TIA.2012.2210015
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper introduces a new method to solve the sensorless control problem for a grid-connected doubly fed induction machine (DFIM). The proposed method is based on high-frequency signal injection and the fact that the rotor of a DFIM can be seen as the rotating secondary of an induction transformer. The commonly used sensorless technique based on stator-flux linkage, aside from being parameter sensitive, does not work during fault ride through (FRT) conditions. Nevertheless, the proposed method is parameter independent and remains fully functional during FRT conditions. Moreover, as opposed to other high-frequency injection methods, the proposed method does not require rotor saliency. The mathematical principle of the proposed technique and its implementation are presented. Computer simulations and initial experimental results are also included for verification.
引用
收藏
页码:1556 / 1564
页数:9
相关论文
共 20 条
  • [1] MRAS observers for sensorless control of doubly-fed induction generators
    Cardenas, Roberto
    Pena, Ruben
    Clare, Jon
    Asher, Greg
    Proboste, Jose
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (03) : 1075 - 1084
  • [2] Effects of Mismatched Parameters in MRAS Sensorless Doubly Fed Induction Machine Drives
    Carmeli, Maria Stefania
    Castelli-Dezza, Francesco
    Iacchetti, Matteo
    Perini, Roberto
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (11) : 2842 - 2851
  • [3] Carmeli S., 2005, International Electric Machines and Drives Conference (IEEE Cat. No.05EX1023C), P404, DOI 10.1109/IEMDC.2005.195754
  • [4] Online grid impedance estimation for single-phase grid-connected systems using PQ variations
    Ciobotaru, Mihai
    Teodorescu, Remus
    Rodriguez, Pedro
    Timbus, Adrian
    Blaabjerg, Frede
    [J]. 2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, : 2306 - 2312
  • [5] Georges S., 2005, P EUR C POW EL APPL, P9
  • [6] Ha JI, 2000, IEEE IND APPLIC SOC, P1802, DOI 10.1109/IAS.2000.882124
  • [7] Stator-flux-oriented control of a doubly-fed induction machine with and without position encoder
    Hopfensperger, B
    Atkinson, DJ
    Lakin, RA
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2000, 147 (04): : 241 - 250
  • [8] Iacchetti M.F., 2010, P 19 ICEM, P1
  • [9] Transducerless field orientation concepts employing saturation-induced saliencies in induction machines
    Jansen, PL
    Lorenz, RD
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (06) : 1380 - 1393
  • [10] High Frequency Grid Impedance Analysis with Three-Phase Converter and FPGA Based Tolerance Band Controller
    Knop, A.
    Fuchs, F. W.
    [J]. CPE: 2009 COMPATIBILITY AND POWER ELECTRONICS, 2009, : 286 - 291