Detecting small anatomical change with 3D serial MR subtraction images

被引:7
|
作者
Holden, M [1 ]
Denton, ERE [1 ]
Jarosz, JM [1 ]
Cox, TCS [1 ]
Studholme, C [1 ]
Hawkes, DJ [1 ]
Hill, DLG [1 ]
机构
[1] Guys Hosp, GKT Med Sch, London SE1 9RT, England
关键词
serial MR; brain; growth hormone; subtraction; visual assessment; anatomical change; registration;
D O I
10.1117/12.348594
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Spoiled gradient echo volume MR scans were obtained from 5 growth hormone (GH) patients and 6 normal controls. The patients were scanned before treatment and after 3 and 6 months of GH therapy The controls were scanned at similar intervals. A calibration phantom was scanned on the same day as each subject. The phantom images were registered with a 9 degree of freedom algorithm to measure scaling errors due to changes in scanner calibration. The second and third images were each registered with a 6 degree of freedom algorithm to the first (baseline) image by maximising normalised mutual information, and transformed,with and without scaling error correction, using sine interpolation. Each registered and transformed image had the baseline image subtracted to generate a difference image. Two neuro-radiologists were trained to detect structural change with difference images containing synthetic misregistration and scale changes. They carried out a blinded assessment of anatomical change for the unregistered; aligned and subtracted; and scale corrected, aligned and subtracted images. The results show a significant improvement in the detection of structural change and inter-observer agreement when aligned and subtracted images were used instead of unregistered ones. The structural change corresponded to an increase in brain:CSF ratio.
引用
收藏
页码:44 / 55
页数:12
相关论文
共 50 条
  • [41] FAST 3D TRACKING AND QUANTIZATION OF SMALL VASCULAR STRUCTURES IN 3D MEDICAL IMAGES
    Afifi, Yusuf I.
    Khalil, Mahmoud I.
    Abbas, Hazem M.
    2015 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2015, : 877 - 881
  • [42] Investigation of a 3D system distortion correction method for MR images
    Stanescu, Teodor
    Jans, Hans-Sonke
    Wachowicz, Keith
    Fallone, B. Gino
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01): : 200 - 216
  • [43] Computation of Aortic Geometry Using MR and CT 3D Images
    Altalhi, Maryam
    Rehman, Sami Ur
    Alam, Fakhre
    Alarood, Ala Abdulsalam
    Rehman, Amin Ur
    Uddin, M. Irfan
    INTELLIGENT AUTOMATION AND SOFT COMPUTING, 2022, 31 (02): : 961 - 969
  • [44] A method for brain 3D surface reconstruction from MR images
    Zhao D.-X.
    Optoelectronics Letters, 2014, 10 (5) : 383 - 386
  • [45] Detection and correction of geometric distortion in 3D CT/MR images
    Breeuwer, M
    Zylka, W
    Wadley, J
    Falk, A
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 78 - 82
  • [46] A method for brain 3D surface reconstruction from MR images
    赵德新
    OptoelectronicsLetters, 2014, 10 (05) : 383 - 386
  • [47] 3D SURFACE RENDERED MR IMAGES OF THE BRAIN AND ITS VASCULATURE
    CLINE, HE
    LORENSEN, WE
    SOUZA, SP
    JOLESZ, FA
    KIKINIS, R
    GERIG, G
    KENNEDY, TE
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (02) : 344 - 351
  • [48] Random forest classification for hippocampal segmentation in 3D MR images
    Maglietta, Rosalia
    Amoroso, Nicola
    Bruno, Stefania
    Chincarini, Andrea
    Frisoni, Giovanni
    Inglese, Paolo
    Tangaro, Sabina
    Tateo, Andrea
    Bellotti, Roberto
    2013 12TH INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND APPLICATIONS (ICMLA 2013), VOL 1, 2013, : 264 - 267
  • [49] Automatic registration of 3D MR images with a computerized brain atlas
    Cuisenaire, O
    Thiran, JP
    Macq, B
    Michel, C
    DeVolder, A
    Marques, F
    MEDICAL IMAGING 1996: IMAGE PROCESSING, 1996, 2710 : 438 - 448
  • [50] Segmentation, registration, and deformation analysis of 3D MR images of mice
    Hamarneh, G
    Chen, J
    Neiman, B
    Henderson, J
    Henkelman, M
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 2, 2003, 2879 : 878 - 885