Towards the Development of a SMA-Actuated MRI-Compatible Tendon-Driven Neurosurgical Robot

被引:0
作者
Ho, Mingyen [1 ]
Desai, Jaydev P. [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, Syst Res Inst, Robot Automat & Med Syst RAMS Lab,Maryland Robot, College Pk, MD 20742 USA
来源
2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA) | 2012年
关键词
DESIGN; FABRICATION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, we present the design and development of a magnetic resonance imaging (MRI)-compatible tendon-driven robot to overcome the limitations of our previous minimally invasive neurosurgical intracranaial robot (MINIR). In this prototype, the robot is made of plastic and the MRI-compatible shape memory alloy (SMA) actuators are placed away from the robot. The robot has four revolute joints which are placed orthogonally to have out-of-plane motion capability. Each joint is connected to a pair of antagonistic SMA spring actuators through the tendon-sheath mechanism. Each SMA spring actuator can be controlled independently to actuate the corresponding joint. A theoretical model and experimental setup have been developed to evaluate the recovery force of the SMA spring at different displacement and temperatures. The experimental results closely match the theoretical model and it shows significant promise for future development in this area. A series of MRI compatibility tests have also been performed to evaluate the MRI compatibility of the device and to assess the degradation in image quality, if any, during actuation. The experimental results clearly demonstrate that the robot is MRI-compatible and it creates no significant distortion in the MR images during actuation.
引用
收藏
页码:683 / 688
页数:6
相关论文
共 25 条
[1]  
Abbott DJ, 2007, 2007 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-9, P416
[2]  
Bo Yang, 2011, IEEE International Conference on Robotics and Automation, P674
[3]  
Brinson LC., 1993, J INTEL MAT SYST STR, V4, P229, DOI DOI 10.1177/1045389X9300400213
[4]   Tendon-Sheath Actuated Robots and Transmission System [J].
Chen Lin ;
Wang Xingsong ;
Tian Fuxiang .
2009 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS 1-7, CONFERENCE PROCEEDINGS, 2009, :3173-3178
[5]  
Chinzei K, 2001, Med Sci Monit, V7, P153
[6]   Design, Fabrication, and Testing of an Insertable Double-Imaging-Region Gradient Coil [J].
Goodrich, K. Craig ;
Hadley, J. Rock ;
Moon, Sung M. ;
Chronik, Blaine A. ;
Scholl, Timothy J. ;
Debever, Joshua T. ;
Parker, Dennis L. .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2009, 35B (02) :98-105
[7]  
Ho M., 2011, P ASME DYN SYST CONT
[8]  
Ho MY, 2011, IEEE INT CONF ROBOT, P1153, DOI 10.1109/ICRA.2011.5980320
[9]   Toward a Meso-Scale SMA-Actuated MRI-Compatible Neurosurgical Robot [J].
Ho, Mingyen ;
McMillan, Alan B. ;
Simard, J. Marc ;
Gullapalli, Rao ;
Desai, Jaydev P. .
IEEE TRANSACTIONS ON ROBOTICS, 2012, 28 (01) :213-222
[10]  
Ho MY, 2010, P IEEE RAS-EMBS INT, P361, DOI 10.1109/BIOROB.2010.5626044